TH15
Modular RTD thermometer, US style

TH15
Modular RTD thermometer, US style ©Endress+Hauser

Best in class temperature measurement for general applications

The robust device is a unit ready for use within and existing thermowell and includes various housing transmitter heads to meet the application and space requirement needs. The unit offers enhanced measurement accuracy and reliability. A variety of connections, dimensions and materials (like 316L SS and Hastelloy C276) offer flexible application possibilities.

  • Vorteile

    • High flexibility due to modular assembly with standard terminal heads and customized immersion length

    • One source shopping for temperature measurement solutions. World class transmitter with integrated sensor offering for heavy process industry...

  • Anwendungsgebiet

    The TH15 temperature sensors are RTD assemblies designed for use in all types of process industries, including harsh environments, due to their rugged design.
    They are made up of a measurement probe with an insulated RTD element and sheath.

    The sensor...

Funktionen und Spezifikationen

Zurück

Details

  • Messprinzip

    Widerstandsthermometer

  • Merkmal / Anwendung

    amerikanische Bauart

    modulares Thermometer

    mit Erweiterung

    mit vorhandenem Schutzrohr verwenden

  • Anschlusskopf

    TA20J - Edelstahl - tiefgezogen mit/ohne Display

    TMT162 - Alu - Feldgehäuse mit/ohne Display

    TMT162 - Edelstahlguss - Feldgehäuse mit/ohne Display

    Alu - Schraubdeckel mit Sicherungskette - E+H blau - Grp. A-G

    PP Kunststoff (FDA gelistet) - Schraubdeckel mit Sicherungskette

    Alu - Klappdeckel

    TMT162/T17 - 316L - hygienisches Feldgehäuse

    TA30H Alu mit/ohne Display

  • Schutzrohr

    zum Einbau in Schutzrohr

  • Messeinsatz

    mineralisoliert (MI), biegsam

    PTFE-isoliert, starr

  • Außendurchmesser Schutzrohr / Messeinsatz

    Messeinsatz 1/4'' (6,35 mm)

  • Max. Eintauchlänge auf Anfrage

    bis 41" (1041mm)

    andere auf Anfrage

  • Werkstoff Schutzrohr

    Mantelleitung

    1.4401 (316)

  • Optionale Beschichtung

    Nicht anwendbar

  • Prozessanschluss

    Schutzrohranschluss

    Außen-Gewinde:

    NPT1/2"
    1-1/4"-18 UNEhttp://webapp.endress.com/ApplMain/
    F

  • Form der Spitze

    gerade

  • Oberflächengenauigkeit Ra

    Nicht definiert

  • Arbeitsbereich

    PT100 WW:

    -200 °C … 600 °C

    (-328 °F … 1.112 °F)

    StrongSens:

    -50 °C … 500 °C

    (-58 °F … 932 °F)

    PT100 TF:

    -50 °C … 200 °C
    (-58 °F … 392 °F)

  • Max. Prozessdruck (statisch)

    Klasse AA nach IEC 60751

    Klasse A nach IEC 60751

    Klasse B nach IEC 60751

  • Genauigkeit

    Klasse A nach IEC 60751

    Klasse B nach IEC 60751

  • Aufnahme Kopftransmitter

    ja (4 … 20 mA; HART; PROFIBUS PA; FOUNDATION FIELDBUS)

  • Ex - Zulassungen

    nur Transmitter

    FM IS

    CSA IS

    FM/CSA IS

  • Zertifikate

    SIL (nur Transmitter)

Dokumente / Handbücher / Software

Zubehör / Ersatzteile

Nr
Order code
Specification