T15
Explosion proof RTD thermometer, US style
Safe monitoring of process temperatures in challenging applications e. g. in the Oil & Gas industry
The robust device is a unit ready for use within and existing thermowell and includes various housing transmitter heads to meet the application and space requirement needs. The unit offers enhanced measurement accuracy and reliability. A variety of connections, dimensions and materials (like 316L SS and Hastelloy C276) offer flexible application possibilities.
-
Vorteile
FM/CSA XP Class I, Div. 1 approved temperature assemblies for maximum safety
One source shopping for temperature measurement solutions. World class transmitter with integrated sensor offering for heavy process industry applications
Remove and install...
-
Anwendungsgebiet
The T15 temperature sensor is a RTD assembly designed for use in harsh environments and explosive areas, due to his FM and CSA approvals.
The sensor is made up of a measurement probe with an insulated RTD element and sheath.
The sensor assembly can be...
Dokumente / Handbücher / Software
-
T13, T14 and T15
RTD assemblies T13, T14 and T15 for heavy duty applications
Technische Information (TI) -
T15
Compact Instructions
RTD explosion proof assembly
Kurzanleitung (KA)02/13Englisch -
Temperature assemblies T15, T55
Measurement inserts TU221, TU211
Installation notes for CSA explosion proof approved apparatus
Temperature Process RTD Explosion Proof T15, Process TC Explosion
Proof T55, RTD insert TU211, TC insert TU221 Installation NotZertifikat FM/CSA (ZD) -
Control Drawing FM Explosionproof T15, T55, TU211, TU221
Temperature Process RTD Explosion Proof T15, Process TC Explosion Proof
T55, RTD insert TU211, TC insert TU221
Installation Notesfor Hazardous LocationsZertifikat FM/CSA (ZD) -
Control Drawing FM XP, NI, DIP
T15, T55, TU211, TU221
Temperature Process RTD Explosion Proof T15, Process TC Explosion
Proof
T55, RTD insert TU211, TC insert TU221
Installation Notesfor Hazardous LocationsZertifikat FM/CSA (ZD) -
Control Drawing CSA Intrinsically Safety, Nonincendive THxx, Txx Series,
TU111, TU121, TU211, TU221
Installation Notes for Hazardous Locations
Zertifikat FM/CSA (ZD) -
Temperature assemblies T15, T55
Measurement inserts TU211, TU221
Installation notes for CSA explosion proof approved apparatus XP, DIP,
NI
Temperature Process RTD Explosion Proof T15, Process TC Explosion
Proof T55, RTD insert TU211, TC insert TU221 Installation NotZertifikat FM/CSA (ZD) -
Temperature assemblies T15, T55
Temperature inserts TU221, TU211
Control drawing FM (XP, DIP)
Installation Notes for FM approved apparatus
Zertifikat FM/CSA (ZD) -
Измерение температуры
Ключевые особенности термометров Endress+Hauser для нефтегазовой отрасли
Kompetenzbroschüre (CP)08/11Russisch -
Инженерные решения по термометрии
Специальные решения по термометрии для химической и
нефтеперерабатывающей промышленностиKompetenzbroschüre (CP)04/10Russisch -
RTD-thermometer, Process TC Heavy duty, Process TC General purpose, Process TC Explosion proof, Process TC direct in contact, Process TC Direct contact, Process RTD Hygienic, Process RTD Heavy duty, Process RTD General purpose, Process RTD Explosion proof, Process RTD direct in contact, Process RTD Direct contact, Plugs RTD direct contact, Magphant, Low cost RTD General purpose, Industrial Modular Thermometer
Produktwurzel: TR15-, TR13-, TR12-, TR11-, TR10-, TMT470L-, TMT162R-, TMT162C-, TMT142R-, TMT142C-, TMR35L-, TMR35-, TMR31L-, TMR31-, TM411-, TM401-, TH56-, TH55-, TH54-, TH53-, TH52-, TH51-, TR24-, TTR35-, TTR31-, TST90-, TST602-, TST487-, TST434-, TST41N-, TST414-, TST410-, TST40N-, TST310-, TST187-, TSM487-, TSM187-, TSC310-, TR88-, TR66-, TR65-, TR63-, TR62-, TR61-, TR25-, TH27-, T55-, T54-, T53-, T15-, T14-, T13-, OTR96-, OTR95-, OTR94-, OTR93-, OTR92-, OTR91-, OTR90-, OTR35-, OTR31-, MLTTS01-, MLTTS00-, GPTL-, DTT35L-, DTT35-, DTT31L-, DTT31-, TAF11-, TH18-, TH17-, TH15-, TH14-, TH13-, TH12-, TH11-, TEC420-, TC88-, TC66-, TC65-, TC63-, TC62-, TC61-, TC15-, TC13-, TC12-, TC10-, TAF16-, TAF12T-, TAF12S-, TAF12D-
Erklärungsnummer: EC_00568_01.17EU ErklärungDeutsch , Englisch , fr -
ACCESSORIES: RTD INSERT, ACCESSORIES: TC INSERT, Process RTD Explosion proof, Process RTD General purpose, Process TC Explosion proof
Produktwurzel: T13-, T14-, T15-, T53-, T54-, T55-, TM111-, TM131-, TU211-, TU221-
Region/Land: USA, Kanada
Zulassungsstelle: CSA
Kategorie: II,III/1/E,F,G/TXXX°C, I/1/1/T6...T1, I/1/A,B,C,D/T6...T1, I/2/A,B,C,D/T6...T1
Zündschutzart: NI, XP, DIPEx AusrüstungEnglisch -
Accessories: RTD insert, Accessories: TC insert, Process RTD Explosion
proof, Process TC Explosion proof
Produktwurzel: T54-, T55-, TU211-, TU221-, T53-, T15-, T14-, T13-
Region/Land: USA
Zulassungsstelle: FM
Kategorie: I,II,II/1,2/ABCDEFG
Zündschutzart: DIP, XPEx AusrüstungEnglisch
Zubehör / Ersatzteile
-
-
Order code 71310423
-
Order code 51004948
Deckelkralle Ersatzteilset Feldgehäuse
Schraube, Scheibe, Federring
-
Order code TMT142X-DA
Display + Halterung + Verdrehsicherung
-
Order code TMT142X-DC
Displayhalterung + Verdrehsicherung
-
-
-
Nr B Order code TMT142X-HA
Gehäusedeckel blind, 316L Ex d, FM XP, CSA XP + Dichtung
-
Nr B Order code TMT142X-HC
Gehäusedeckel kpl.für Display, 316L Ex d FM XP, CSA XP + Dichtung
-
Nr B Order code TMT142X-HH
Gehäusedeckel blind, Alu Ex d, FM XP + Dichtung CSA-Zul. nur als Abdeckung Anschlussraum
-
Nr B Order code TMT142X-HK
Gehäusedeckel kpl. für Display, Alu Ex d + Dichtung
-
Nr B Order code TMT162X-HA
Gehäusedeckel blind, 316L Ex d ATEX Ex d, FM XP + Dichtung CSA-Zul.nur als Abdeckung Anschlussraum
-
Nr B Order code TMT162X-HC
Gehäusedeckel kpl. für Display,Ex d 316L ATEX Ex d, FM XP, CSA XP + Dichtung
-
Nr B Order code TMT162X-HH
Gehäusedeckel blind Alu Ex d FM XP + Dichtung CSA-Zul. nur als Abdeckung Anschlussraum
-
Nr B Order code TMT162X-HK
Gehäusedeckel kpl. für Display Alu Ex d + Dichtung
-
-
-
Order code 51006845
Kabelverschraubung NPT1/2 D4,5-8,5 IP68
-
Order code 51007995
Montagehalter Rohr 1,5-3" Edelstahl 316L
-
Order code 71044062
Beistellset kpl.TMT82/84/85 USA(amerik.)
2x Schraube,1x Dichtung CDI-Stecker
-
Order code TMT162X-DA
Display HART5 + Halterung + Verdreh- sicherung
-
Order code TMT162X-DB
Display PA/FF + Halterung + Verdreh- sicherung
-
Order code TMT162X-DC
Displayhalterung + Verdrehsicherung
-
Order code TMT162X-DD
Display HART7 + Halterung + Verdreh- sicherung
-
Order code TMT162A-MA
Mounting bracket,North American region standard model,stainl.steel wall/tube 2"
-
Order code TMT162A-MB
Cable gland NPT1/2, North American region standard model,2xD0.5 cables
-
Order code TMT162A-MD
Montagehalter Rohr 2"/V4A
-
Order code 71003600
Klemmenblock 3pol Limatherm B14S-HS18
-
Order code 71039736
Klemmenblock 4pol Limatherm B14S-HS18
-
Order code 71386275
Integrierbarer Überspannungsschutz
zur nachträglichen Montage in einem Feldtransmitter. Kompatibilität beachten.
-
-
-
Nr A Order code TU211-
RTD-Einsatz TU211 Ex-Zertif. US-Typ
Ersatzteil. Flammdurchschlagsperre. Federvorspannung. Pt100 Sensor entspricht IEC60751 Standard, alpha=0.00385.
-
-
-
Nr B Order code TA30H-
Anschlusskopf TA30H
Aufnahme für Anschlussklemmenblock oder Kopftransmitter + optionale Anzeige. Design: druckfeste Kapselung. Deckel: geschraubt, optionales Fenster. Material: Aluminium. Pulverbeschichtung: Polyester. Farbe: Grundkörper blau, Deckel grau. Umgebungstemp.: -50..150 oC (Gehäuse). Schutzart: IP66/68, NEMA 4X (Gehäuse). Schutzart Ex d/XP: IP66/67 (Gehäuse).
-
-
-
Order code TMT142E-
Elektronik TMT142E
-
Order code TMT162E-
Elektronik TMT162E
-
Order code TMT180-
iTEMP TMT180, Kopftransmitter Pt100
Temperaturtransmitter,PC-programmierbar. Anwendung: RTD. 2-Leiter 4-20mA. Fehlerverhalten: NAMUR NE 43. Montage: Kopf Form B, DIN EN50446. UL gelistet.
-
Order code TMT181-
iTEMP TMT181, Kopftransmitter PCP
Temperaturtransmitter,PC-programmierbar. Anwendung: RTD, TC, Ohm, mV. 2-Leiter 4-20mA, galvanische Trennung. Fehlerverhalten: NAMUR NE 43. Montage: Kopf Form B, DIN EN50446. UL gelistet.
-
Order code TMT182-
iTEMP TMT182, Kopftransmitter HART
Temperaturtransmitter, Protokoll HART. Anwendung: RTD, TC, Ohm, mV. 2-Leiter 4-20mA, galvan.Trennung. Fehlerverhalten: NAMUR NE 43. Montage: Kopf Form B, DIN EN50446. UL gelistet.
-
Order code TMT82-
iTEMP TMT82, Transmitter HART
Messumformer in 2-Leiter Technik. 2 universelle Sensoreingänge. Galv. Trennung 2kV (Eingang/Ausgang). Applikation: RTD, TC, Ohm und mV. ::Hochzuverlässig durch Drifterkennung und Sensorbackup. ::Optional auch für sicherheitsrelevante Anwendungen durch SIL2/3 nach IEC61508.
-
Order code TMT84-
iTEMP TMT84, Transmitter PA
2 Sensor Eingänge. Diagnosefunktionen: Sensorüberwachung. PROFIBUS PA Profile 3.02. Galvanische Trennung 2kV. Applikation: RTD, TC, Ohm, mV. Stromaufnahme: 11 mA. Montage: Anschlusskopf Form B, DIN EN50446. Werkseinstellung: CH1: Pt100, 3-Leiter, oC. CH2: nicht aktiv. Abweichende Konfiguration optional wählbar.
-
Order code TMT85-
iTEMP TMT85, Transmitter FF
2 Sensor Eingänge. Diagnosefunktionen: Sensorüberwachung. FOUNDATION Fieldbus Protokoll. Galvanische Trennung 2kV. Applikation: RTD, TC, Ohm und mV. Stromaufnahme: 11mA. Montage: Anschlusskopf Form B, DIN EN50446. Werkseinstellung: CH1: Pt100, 3-Leiter, oC. CH2: nicht aktiv. Abweichende Konfiguration optional wählbar.
-
Order code TID10-
Anzeigeeinheit Kopftransmitter TID10
zum Aufstecken. Dot-Matrix Messwertanzeige. 12 DIP-Schalter, rückseitig. Einstellungen: FF: Simulation, Write Lock. PA: Busadressierung, Write Lock. Kompatibel: TMT85, TMT84, TMT82.
-
Order code TXU10-
Konfigurationskit TXU10-
für PC-programmierbare Baugruppen. Setup-Programm+Schnittstellenkabel für PC mit USB-Port.
-
Order code FXA195-
Commubox FXA195
Modem zur Anbindung von HART Feldgeräten an den Computer via USB. Inbetriebnahme von Feldgeräten mit Bediensoftware. :: Zum Anschluss an eigensichere Signalstromkreise (4-20mA). :: SIL2, IEC61508.
-
Order code READWIN-
Readwin 2000 Bedien- + Auslesesoftware
-