Training
Ultrasonic measurement
Time-of-Flight
Prosonic FMU90
Transmitter in housing for field or top hat rail mounting for up to 2 sensors FDU90/91/92/93/95
Prosonic FMU90 separated version with field housing or top hat rail housing for control cabinet instrumentation are suited for continuous, non-contact level measurement of fluids, pastes, sludge and powdery to coarse bulk solids. Also the flow measurement in open channels and weirs is possible as the simultaneous measurement of level and flow in a storm water overflow basin with only 1 sensor. Up to 6 relays for tendency alarm, flow pulse output or backwater/sludge alarm, 1 or 2 channel version.
- F
- L
- E
- X
-
Standard products
- Reliable, robust and low-maintenance
Technical excellence
Simplicity
-
Specialized products
- Designed for demanding applications
Technical excellence
Simplicity
Variable
FLEX selections | Technical excellence | Simplicity |
---|---|---|
Fundamental selection Meet your basic measurement needs |
Technical excellence
|
Simplicity
|
Lean selection Handle your core processes easily |
Technical excellence
|
Simplicity
|
Extended selection Optimize your processes with innovative technologies |
Technical excellence
|
Simplicity
|
Xpert selection Master your most challenging applications |
Technical excellence
|
Simplicity
Variable |
-
Specs at a glance
-
Accuracy
+/- 2mm + 0.17% of measured distance
-
Quick selection
Individual configuration
-
Benefits
Simple, menu-guided operation with 6-line plain text display, 15 languages selectable
Envelope curves on the display for quick and simple diagnosis
Easy operation, diagnosis and measuring point documentation with the supplied "FieldCare" operating program
...
-
Field of application
Level measurement of fluids and bulk materials with 1 or 2 sensors for measuring of up to 45m (148ft) and level limit detection. Pump control, rake control and as option: additional pump control function.
Calculations: Average, difference, sum
...
Documents / Manuals / Software
-
Weld-in adapter, process adapter and flanges
Level and pressure measurement
Technical Information (TI) -
Prosonic S FMU90
Ultrasonic measuring technology
Technical Information (TI) -
Prosonic S FMU90
PROFIBUS DP
Flow measurement
Backwater and dirt detection
Daily counters and totalizersOperating Instruction (BA) -
Prosonic S FMU90
PROFIBUS DP
Level measurement
Alternating pump control
Rake controlOperating Instruction (BA) -
Prosonic S FMU90
Ultrasonic Transmitter
Operating Instruction (BA) -
Prosonic S FMU90
Slot-Index Lists for PROFIBUS DP
Operating Instruction (BA) -
Prosonic S FMU90
HART
Level measurement
Alternating pump control
Rake controlOperating Instruction (BA) -
Prosonic S FMU90
HART
Flow measurement
Backwater and dirt detection
Daily counters and totalizersOperating Instruction (BA) -
Prosonic S FMU90
Level measurement
Flow measurement over open channelsDevice Parameter (GP) -
Prosonic S FMU90
HART
Level measurement
Alternating pump control
Rake controlShort Instruction (KA)08/20English -
Prosonic S FMU90
PROFIBUS DP
Level measurement
Alternating pump control
Rake controlShort Instruction (KA)08/20English -
Prosonic S FMU90
HART
Flow measurement
Backwater and dirt detection
Daily counters and totalizersShort Instruction (KA)08/20English -
Prosonic S FMU90
PROFIBUS DP
Flow measurement
Backwater and dirt detection
Daily counters and totalizersShort Instruction (KA)08/20English -
Exchange of electronic modules on Prosonic S
Exchange of electronic modules on Prosonic S
Short Instruction (KA)04/12German , English -
Adapter plate for Prosonic S FMU90/FMU95
Mounting Instructions
Short Instruction (KA)01/08German , English -
Prosonic S FMU90
Quick Setup
Transmitter in housing for field or top-hat rail mounting for the
ultrasonic sensors FDU91/91F/92/93/95/96Short Instruction (KA)01/06German , English -
Fuse set - installation instruction
Prosonic S
Installation Instructions (EA) -
Electronics basic version and PC boards
Installation Instructions
Prosonic S FMU9x; Tankvision NXA20, NXA82x
Installation Instructions (EA) -
Prosonic S FMU90, FMU95
EAC:
Ex tc IIIC T90°C Dc X
Safety Instructions
Ultrasonic Level Measurement
Ex Safety Instructions (XA) -
Prosonic S FMU90, FMU95
II 3 D Ex tc IIIC T 90 °C Dc IP66
Safety Instructions
Ultrasonic Level Measurement
Ex Safety Instructions (XA) -
List of Tested Devices and Versions ME01
Mitsubishi Electric MELSEC System Q and PROFIBUS for Water &
Wastewater Industry
This document lists all relevant components and devices with versions as
used for
testing of the Reference Topology ME01. All content of this document is
jointly
developed, reviewed and approved by Mitsubishi Electric and
Endress+Hauser as a
common deliverable of Open Integration.Special Documentation (SD) -
Integration Tutorial ME01
Mitsubishi Electric MELSEC System Q and PROFIBUS for Water &
Wastewater Industry
This document provides a step by step description on how to integrate
Endress+Hauser
PROFIBUS devices with the Mitsubishi Electric MELSEC Q System. All
content of this
document is jointly developed, reviewed and approved by Mitsubishi
Electric and
Endress+Hauser as a common deliverable of Open Integration.Special Documentation (SD) -
Reference Topology ME01
Mitsubishi Electric MELSEC System Q and PROFIBUS for Water &
Wastewater Industry
This document specifies the Open Integration Reference Topology ME01.
All content of
this document is jointly developed, reviewedand approved by Mitsubishi
Electric and
Endress+Hauser as a common deliverable of Open Integration.Special Documentation (SD) -
Integration Test Summary ME01
Mitsubishi Electric MELSEC System Q and PROFIBUS for Water &
Wastewater Industry
This document provides a brief summary of Open Integration tests for
Reference
Topology ME01. All content of this document is jointly developed,
reviewed and
approved by Mitsubishi Electric and Endress+Hauser as a common
deliverable of Open
Integration.Special Documentation (SD) -
Please fill in. (You can find example text among the HELP menu)
Please fill in. (You can find example text among the HELP menu)
Manufacturer Information (MI) -
Simatic PDM PROFIBUS Package V1.12.00
Manufacturer Information includes PDM - Device List, Release Notes –
PROFIBUS
Manufacturer Information for users regarding software updates
(following the NAMUR recommendation 53)
New software version: 1.12.00Manufacturer Information (MI) -
PRM HART Package V1.08.00
Manufacturer Information includes PRM - Device List, Release Notes –
HART
Manufacturer Information for users regarding software updates
(following the NAMUR recommendation 53)
New software version: 1.08.00Manufacturer Information (MI) -
AMS HART Package V1.12.00
Manufacturer Information includes AMS - Device List, Release Notes –
HART
Manufacturer Information for users regarding software updates
(following the NAMUR recommendation 53)
New software version: 1.12.00Manufacturer Information (MI) -
Prosonic S FMU90
Manufacturer Information for users regarding software updates (NE53)
Software version V02.00.00 HART and PROFIBUS DP
Manufacturer Information (MI) -
Please fill in. (You can find example text among the HELP menu)
Please fill in. (You can find example text among the HELP menu)
Manufacturer Information (MI) -
AMS FOUNDATION fieldbus Package V1.06.00
Manufacturer Information includes AMS - Device List, Release Notes –
FOUNDATION fieldbus
Manufacturer Information for users regarding software updates
(following the NAMUR recommendation 53)
New software version: 1.06.00Manufacturer Information (MI) -
Prosonic S FMU90 / FMU95
Manufacturer Information for users regarding software updates (NE53)
Software version
FMU90: V02.01.00 HART and PROFIBUS DP and
FMU95: V01.01.00 PROFIBUS DPManufacturer Information (MI) -
Prosonic S FMU90
Manufacturer Information for users regarding software updates (NE53)
Software version V01.00.02 (HART and Profibus DP)
Manufacturer Information (MI) -
PRM FOUNDATION fieldbus Package V1.05.00
Manufacturer Information includes PRM - Device List, Release Notes –
FOUNDATION fieldbus
Manufacturer Information for users regarding software updates
(following the NAMUR recommendation 53)
New software version: 1.05.00Manufacturer Information (MI) -
Simatic PDM HART Package 1.14.00
Manufacturer Information includes PDM - Device List, Release Notes –
HART
Manufacturer Information for users regarding software updates
(following the NAMUR recommendation 53)
New software version: 1.14.00Manufacturer Information (MI) -
perspektiven Umwelt 2014
Kundenmagazin: Wasser ist unser Leben
Customer Magazine (CM)01/14German -
Control Engineering maj 2007
Funkcje sterowania dla obiektów wodno-&
347;ciekowych w ultradzwi
&
281;kowych przetwornikach pomiarowychPublications (PU)05/07Polish -
Catálogo Medición y Detección de nivel
Gama de productos para aplicaciones con líquidos y sólidos
Fields of Activities (FA)09/19Spanish -
Mesure de niveau
Aperçu des produits pour des applications dans des liquides et des
solides en vracFields of Activities (FA)03/19fr -
Level measurement
Product overview for applications in liquids and bulk solids
Fields of Activities (FA)03/17English -
Füllstandmesstechnik
Produktübersicht für Anwendungen in Flüssigkeiten und Schüttgütern
Fields of Activities (FA)03/17German -
Level measurement
Product overview for applications in liquids and bulk solids
Fields of Activities (FA)03/17English -
New measurement technology and control to ensure reliable operation of
the rain water collection tank and pre-sewer treatment
Bözen is located at the foot of the Bözberg mountain in the canton of
Aargau, exactly halfway between Basel and Zurich. The community with
roughly 650 inhabitants is one of the oldest wine-growing areas of this
region. A Sewage Board was founded years ago together with 4
associated nearby communities. Also included in its sphere of influence
is the storm water basin of the Bözen municipality. The waste water of
the co-operative sewage district is purified in a common treatment plant
at the outlet of the lowest lying community.Case Studies (CS)12/10English -
Prosonic S provides reliable control of filtration for raw sewage water
FMU90 transmitter and FDu92 sensor provides filter control in wastewater
Case Studies (CS)10/07English -
Ultrasonic transmitter FDU95 and FMU90 processes bulk pellet feed for
farm animals
Suitable for narrow silos filled with corn, barley wheat and soy where
environment is dusty.Case Studies (CS)07/10English -
Level measurement in polymer station with ultrasonic level sensor
For the different treatment processes, wastewater plants produce huge
amounts of sewage sludge annually. Since this must be disposed of
through landfill or incineration, it is essential to try to render
residual
sludge as dry as possible.Case Studies (CS)06/11English -
Level measurement in pulp slurry in a vertical holding silos of sawdust
fines and small wood chips
FMU 90 and FDU 93 ultrasonic system maintains level in vertical holding
silos precisly and elminated weekly cleaning and maintenance
requirements.Case Studies (CS)06/10English -
Prosonic S Transmitter via HART to the PlantPAx Process Automation
System
System using a ControlLogix 1756 HART Analog Input Module
Integration DocumentSystem Partner (SP)01/09English -
Prosonic S FMU90, 1 Kanal Füllstand
Ultraschallmessumformer bestehend aus Grundausführung mit
Basisfunktionalität und optional wählbaren Erweiterungen/Funktionen zur
Messung von Füllstand / VolumenTender Text12/12German -
Prosonic S FMU90, 1 Kanal Durchfluss
Ultraschallmessumformer bestehend aus Grundausführung und optional
wählbaren Erweiterungen zur Messung von Durchfluss in offenen
Gerinnen /
Wehren inkl. anwendungsspezifischer Relais-SteuerfunktionenTender Text12/12German -
Prosonic S FMU90_1D
Ultrasonic transmitter of standard configuration and optional selectable
expansion features for measuring the flow in open channels/weirs, incl.
application-specific relay control functionsTender Text09/06us -
Prosonic S FMU90EN
Ultrasonic transmitter of standard configuration with basic
functionality and optional selectable expansion features/functions for
measuring level/volume/difference/mean value/flow rate in open
channels/weirs, pump, calculation and timing controlTender Text09/06us -
Prosonic S FMU90_1F
Ultrasonic transmitter of standard configuration with basic
functionality and optional selectable expansion features/functions for
level/volume measurementTender Text09/06us -
Prosonic S FMU_2FD
Ultrasonic transmitter with basic functionality and optional selectable
expansion features/functions for measuring level/volume/difference/mean
value/flow rate in open channels/weirs, pump, calculation and timing
control
.Tender Text09/06us -
Montageplatte für FMU90
Montageplatte für FMU90 im Feldgehäuse
Tender Text06/16German -
Prosonic S FMU90 HART
Ultraschallmessumformer bestehend aus Grundausführung und optional
wählbaren
Erweiterungen zur Messung von Durchfluss in offenen Gerinnen / Wehren
inkl.
anwendungsspezifischer Relais-SteuerfunktionenTender Text06/16German -
Prosonic S FMU90
Ultraschallmessumformer bestehend aus Grundausführung mit
Basisfunktionalität und
optional wählbaren Erweiterungen/Funktionen zurMessung von Füllstand /
Volumen /
Differenz / Mittelwert / Durchfluss in offenen Gerinnen / Wehren,
Pumpen-, Rechen-
und ZeitsteuerungTender Text06/16German -
Klimaschutzhaube für FMU90
Klimaschutzhaube für FMU90 im Feldgehäuse
Tender Text06/16German -
Prosonic FMU90, 2 Kanal Füllstand und Durchfluss
Ultraschallmessumformer bestehend aus Grundausführung mit
Basisfunktionalität und optional wählbaren Erweiterungen/Funktionen zur
Messung von Füllstand / Volumen / Differenz / Mittelwert / Durchfluss in
offenen Gerinnen / Wehren, Pumpen-, Rechen- und ZeitsteuerungTender Text06/07German -
GSD Single, GSD_EH_DP_LE_Prosonic_0x1540_V02_00_00_DPLIB, 17.04.2014 (Lev
el, Prosonic S, 0x1540)
PROFIBUS DP,
PROFIBUS System Version: AnyGeneral Station Description (GSD)2.00.00Language neutral -
EDD Single, PDM_HART_LE_ProsonicS_0x001B_0x03_0x01, 07.11.2018 (Level, Prosonic S, 0x001B)
HART,
PDM Version: 6.0 SP5Electronic Data Description (EDD)1.00.00Language neutral -
EDD Single, PDM_HART_LE_ProsonicS_0x001B_0x01_0x01, 07.11.2018 (Level, Prosonic S, 0x001B)
HART,
PDM Version: 6.0 SP5Electronic Data Description (EDD)1.00.00Language neutral -
EDD Single, PDM_DP_LE_ProsonicS_0x1540_0x02_0x01, 07.01.2019 (Level, Prosonic S, 0x1540)
PROFIBUS DP,
PDM Version: 6.0 SP5Electronic Data Description (EDD)1.00.00Language neutral -
EDD Single, PDM_HART_LE_ProsonicS_0x001B_0x02_0x01, 07.11.2018 (Level, Prosonic S, 0x001B)
HART,
PDM Version: 6.0 SP5Electronic Data Description (EDD)1.00.00Language neutral -
EDD Single, PDM_DP_LE_ProsonicS_0x1540_0x03_0x04, 06.06.2017 (Level, Prosonic S, 0x1540)
PROFIBUS DP,
PDM Version: 6.0 SP5, 8.2Electronic Data Description (EDD)1.00.00Language neutral -
DTM Single, ProsonicS_FMU9x_DP_V1_00_xx, 19.10.2020 (Level, Prosonic S, 0x1540)
PROFIBUS DP,
DeviceCare Version: 1.07.00
Field Xpert - SMT70 Version: 1.05.00
FieldCare Version: 2.15.00Device Type Manager (DTM)1.5.155.349Language neutral -
DTM Single, ProsonicS_FMU90_DP_V2_00_xx, 19.10.2020 (Level, Prosonic S, 0x1540)
PROFIBUS DP,
DeviceCare Version: 1.07.00
Field Xpert - SMT70 Version: 1.05.00
FieldCare Version: 2.15.00Device Type Manager (DTM)1.5.155.349Language neutral -
DTM Single, ProsonicS_FMU90_DP_V2_01_xx, 19.10.2020 (Level, Prosonic S, 0x1540)
PROFIBUS DP,
DeviceCare Version: 1.07.00
Field Xpert - SMT70 Version: 1.05.00
FieldCare Version: 2.15.00Device Type Manager (DTM)1.5.155.349Language neutral -
DTM Single, ProsonicS_FMU9x_V01_00_xx, 23.10.2020 (Level, Prosonic S, 0x001B)
HART,
DeviceCare Version: 1.07.00
Field Xpert - SMT70 Version: 1.05.00
FieldCare Version: 2.15.00Device Type Manager (DTM)1.4.188.39Language neutral -
DTM Single, ProsonicS_FMU90_V2_00_xx, 23.10.2020 (Level, Prosonic S, 0x001B)
HART,
DeviceCare Version: 1.07.00
Field Xpert - SMT70 Version: 1.05.00
FieldCare Version: 2.15.00Device Type Manager (DTM)1.4.188.39Language neutral -
DTM Single, ProsonicS_FMU90_V2_01_xx, 23.10.2020 (Level, Prosonic S, 0x001B)
HART,
DeviceCare Version: 1.07.00
Field Xpert - SMT70 Version: 1.05.00
FieldCare Version: 2.15.00Device Type Manager (DTM)1.4.188.39Language neutral -
Radar or ultrasonic measurement
Animation DE 960x540 mp4
Animation07/16German -
Radar or ultrasonic measurement
Animation FR 1280x720 mp4
Animation07/16fr -
Radar or ultrasonic measurement
Animation mp4 EN
Animation06/15English -
Radar or ultrasonic measurement
Animation flv EN
Animation06/15English -
Prosonic S
Product Code: FMU90-
Declaration Number: HE_00619_01.17
Manufacturer Specification: RoHSManufacturer DeclarationChinese -
Prosonic S
Product Code: FMU90-, FMU95-
EU DeclarationGerman , English -
Prosonic S
Product Code: FMU90-, FMU95-
EU DeclarationGerman , English , fr -
Levelflex, Micropilot, Soliphant T, Soliphant M, Solicap S, Solicap M, Prosonic S, Prosonic M, Nivector, Minicap
Product Code: FMP57-, FMP56-, FMR57-, FMR56-, FMR67-, FTM52-, FTM51-, FTM50-, FTM21-, FTM20-, FTI77-, FTI56-, FTI55-, FTC968Z-, FTC968-, FTC262-, FTC260-, FMU95-, FMU90-, FMU44-, FMU43-, FMU42-, FMU41-, FMU40-, FDU95-, FDU93-, FDU92-, FDU91F-, FDU91-, FDU90-
Region/Country: Russia (Declaration of Conformity), Russia (TR CU)
Approval Agency: EAC
Approval Number: RU D-DE.MO10.B.05554MiscellaneousRussian -
Prosonic S
Product Code: FMU90-, FMU95-
Region/Country: Russia (TR CU)
Approval Agency: EAC
Approval Number: TC BY_112 11.01. TP004 003 127MiscellaneousRussian -
Prosonic M, Prosonic S, Prosonic T
Product Code: FMU95-, FMU90-, FMU44-, FMU43-, FMU42-, FMU41-, FMU40-, FMU30-, FDU96-, FDU95-, FDU93-, FDU92-, FDU91-, FDU90-
Region/Country: Russia (TR CU)
Approval Agency: EAC
Approval Number: TC BY_112 11.01. TP020 003 127MiscellaneousRussian -
Levelflex, Micropilot, Soliphant T, Soliphant M, Solicap S, Solicap M, Prosonic S, Prosonic M, Nivector, Minicap
Product Code: FMP57-, FMP56-, FMR57-, FMR56-, FMR67-, FTM52-, FTM51-, FTM50-, FTM21-, FTM20-, FTI77-, FTI56-, FTI55-, FTC968Z-, FTC968-, FTC262-, FTC260-, FMU95-, FMU90-, FMU44-, FMU43-, FMU42-, FMU41-, FMU40-, FDU95-, FDU93-, FDU92-, FDU91F-, FDU91-, FDU90-
Region/Country: Russia (Declaration of Conformity), Russia (TR CU)
Approval Agency: EAC
Approval Number: RU D-DE.MO10.B.05551MiscellaneousRussian -
Prosonic M, Prosonic S
Product Code: FDU90-, FDU91-, FDU91F-, FDU92-, FDU93-, FDU95-, FMU40-, FMU41-, FMU42-, FMU43-, FMU44-, FMU90-, FMU95-
Region/Country: Russia (TR CU)
Approval Agency: EAC
Approval Number: TС RU D-DE.MU62.B.02534MiscellaneousRussian -
Prosonic M, Prosonic S, Prosonic T
Product Code: FMU95-, FMU90-, FMU44-, FMU43-, FMU42-, FMU41-, FMU40-, FMU30-, FDU95-, FDU93-, FDU92-, FDU91F-, FDU91-, FDU90-
Region/Country: Russia (TR CU)
Approval Agency: EAC
Protection: Ex d [ia], Ex ia, Ex m, Ex nA, Ex t, Ex ta/tc, Ex ta/tbExplosion ProtectionRussian -
Product Family: Prosonic S
Product Code: FMU90-
Region/Country: International
Approval Agency: PI, PROFIBUS International
Software Version: PROFILE 3.0Fieldbus ConformanceEnglish -
Prosonic S
Product Code: FDU90-, FDU91-, FDU91F-, FDU92-, FDU93-, FDU95-, FDU96-, FMU90-, FMU95-
Region/Country: Slovakia
Approval Agency: SMUB
Approval Number: 018/144/10Metrology -
Prosonic M, Prosonic S, Prosonic T
Product Code: FMU95-, FMU90-, FMU44-, FMU43-, FMU42-, FMU41-, FMU40-, FMU30-, FDU96-, FDU95-, FDU93-, FDU92-, FDU91-, FDU90-
Region/Country: Belarus
Approval Agency: BEL
Approval Number: 9773MetrologyRussian -
Prosonic S
Product Code: FDU91-, FDU91F-, FDU92-, FDU93-, FDU95-, FDU96-, FMU90-, FMU95-
Region/Country: Slovakia
Approval Agency: SMUB
Approval Number: 144/10-018Metrology -
Prosonic M, Prosonic S
Product Code: FDU91F-, FDU92-, FDU93-, FDU95-, FDU96-, FMU40-, FMU41-, FMU42-, FMU43-, FMU44-, FMU90-, FMU95-
Region/Country: Russia (GOST)
Approval Agency: Rosstandart
Approval Number: OC.C.29.004.A № 50999/1MetrologyRussian -
Prosonic M, Prosonic S, Prosonic T
Product Code: FMU95-, FMU90-, FMU44-, FMU43-, FMU42-, FMU41-, FMU40-, FMU30-, FDU96-, FDU95-, FDU93-, FDU92-, FDU91F-, FDU91-
Region/Country: Uzbekistan
Approval Agency: UZS
Approval Number: 02.6925MetrologyRussian -
Prosonic M, Prosonic S, Prosonic T
Product Code: FMU95-, FMU90-, FMU44-, FMU43-, FMU42-, FMU41-, FMU40-, FMU30-, FDU96-, FDU95-, FDU93-, FDU92-, FDU91F-, FDU91-, FDU90-
Region/Country: Kazakhstan
Approval Agency: KazInMetr
Approval Number: 12134MetrologyRussian -
Prosonic, Prosonic M, Prosonic S
Product Code: FDU91-, FMU40-, FMU41-, FMU42-, FMU43-, FMU44-, FMU90-
Region/Country: Malaysia
Approval Number: SPAN/BPI/2653-2019MetrologyEnglish -
Prosonic S
Product Code: FMU90-, FMU95-
Region/Country: Canada
Approval Agency: CSAOrdinary Location Product SafetyEnglish
Accessories / Spare parts
-
-
Nr 10 Order code 52025713
Housing DIN Rail FMU9x
Basic version. Consists of: Frame. 2x side part. Locking DIN Rail. Usage: FMU90/FMU95. -For E+H service only-
-
-
-
Nr 11 Order code 52025695
Mounting plate FMU9x field housing, PC
Material: plastics. Usage: FMU90/FMU95.
-
-
-
Nr 12 Order code 52025702
Separating web + fixing PC board
Torx screw, field housing. Usage: FMU90/FMU95.
-
-
-
Nr 13 Order code 52025712
-
-
-
Nr 20 Order code 52025699
Cover P3+display field housing, PC,FMU90
Material: plastics. Display cover, hinge. Usage: FMU90.
-
Nr 20 Order code 52025700
Cover P3 field housing, hinge, FMU90
Material: plastics. Blind cover, hinge. Usage: FMU90.
-
Nr 20 Order code 52025703
Front plate small FMU90 + display
Display module. Material: plastics. Basic version DIN Rail. Usage: FMU90.
-
Nr 20 Order code 52025705
Front plate small FMU90
Material: plastics. Basic version DIN Rail. Usage: FMU90.
-
Nr 20 Order code 52025708
-
Nr 20 Order code 52025710
Front plate wide FMU90 + display
Display module. Material: plastics. DIN Rail, extended. Usage: FMU90.
-
-
-
Nr 21 Order code 71024576
Hinge + screws, field housing FMU9x
Consists of: 2x hinge. 4x screw. Usage: FMU90/FMU95.
-
-
-
Order code 71024578
-
-
-
Nr 21 Order code 52025711
Front plate small FMU90, blind cover
Material: plastics. DIN Rail version, maximum. Usage: FMU90.
-
-
-
Nr 25 Order code 52025721
Cable display FMU9x, L=300mm
Connection cable. Display / basic electronics. Field housing. Usage: FMU90/FMU95.
-
Nr 25 Order code 52025722
Cable display FMU9x, L=220mm
Connection cable. Display / basic electronics. DIN Rail mounting. Usage: FMU90/FMU95.
-
-
-
Nr 31 Order code 52025714
-
Nr 31 Order code 52025715
-
Nr 31 Order code 52025716
-
-
-
Nr 33 Order code 52025718
PC board 2x relays SPDT, additional
Usage: version 3 relay, FMU90. 1 relay included in electronics FMU90/FMU95.
-
Nr 33 Order code 52025719
PC board 5x relay SPDT, additional
Usage: version 6 relay, FMU90. 1 relay included in electronics FMU90/FMU95.
-
-
-
Nr 34 Order code 52025720
-
-
-
Nr 35 Order code 71035384
-
-
-
Nr 39 Order code 71024577
PCB connector set FMU9X, 6 pieces
Consists of: 1x PCB connector power supply. 2x PCB connector relay. 2x PCB connector current. Output/synchronisation. 1x PCB connector sensor output. Usage: FMU90/FMU95.
-
-
-
Nr 36 Order code 71354876
-
-
-
Order code 71020896
Remote display FMU90, illuminated
Panel mounting. Connection cable 3m. Usage: FMU90.
-
-
-
Nr 30 Order code FMU90X-
-
-
-
Order code 71024579
Fuse set FMU9x, AC+DC
Consists of: 1x fuse 400mA T, AC version. 1x fuse 2,0A T, DC version. 2x fuse holder. Usage: FMU90/FMU95.
-
Order code 71020897
Cable 3m, remote display FMU9x
Connection cable FMU9x / remote display. Usage: FMU90/FMU95.
-
Order code 52024477
Weather prot.cover FMU90/95 fieldhousing
Material: 316Ti. Usage: FMU90/FMU95.
-
Order code 52024478
Mounting plate FMU90/95 fieldhousing
Material: 316Ti. Usage: pipe, 1" / 2", FMU90/FMU95.
-
Order code 52026736
Adapter cable FMU9x
Connection service tool RS232(52013675) Usage: FMU90/FMU95.
-
Order code 71093130
Mounting bracket Prosonic S, Micropilot
Material: 316L. Usage: FDU90/FDU91/FDU91F/FDU92/FDU93/FDU95, FMR10, FMR20, FMU90/FMU95.
-
-
Predecessor