-
Seminar
iTEMP TMT162
Temperature field transmitter
Electronic monitoring, conversion and display of input signals - all over the industries
Unsurpassed reliability, accuracy and long-term stability in critical processes. The remote configurable transmitter transfers and monitors converted signals from RTD sensors and thermocouples as well as from resistance and voltage signals using selectively HART®, FOUNDATION Fieldbus™-, PROFIBUS® PA-communication. It visualizes the signals on its own backlit display. A field housing allows a direct connection in harsh process areas as well as in hygienic applications as option.
- F
- L
- E
- X
-
Standard products
- Reliable, robust and low-maintenance
Technical excellence
Simplicity
-
Specialized products
- Designed for demanding applications
Technical excellence
Simplicity
Variable
FLEX selections | Technical excellence | Simplicity |
---|---|---|
Fundamental selection Meet your basic measurement needs |
Technical excellence
|
Simplicity
|
Lean selection Handle your core processes easily |
Technical excellence
|
Simplicity
|
Extended selection Optimize your processes with innovative technologies |
Technical excellence
|
Simplicity
|
Xpert selection Master your most challenging applications |
Technical excellence
|
Simplicity
Variable |
-
Specs at a glance
-
Accuracy
(Pt100, -50...200 °C) <= 0,15 K (HART)
(Pt100, -58...392 °F) <= 0,3 °F (HART)
(Pt100) <= 0,1 K (FF, PA)
(Pt100) <= 0,18 °F (FF, PA)
-
Quick selection
Individual configuration
-
Benefits
High reliability in harsh industrial environments due to dual compartment housing and compact, fully potted electronics
Backlit display with large measured value, bar graph and status condition indication
Diagnostics information according to NAMUR NE107
...
Documents / Manuals / Software
-
TMT162R
RTD assembly with HART®-, FOUNDATION Fieldbus™- or PROFIBUS® PA field
transmitterTechnical Information (TI) -
iTEMP TMT162,
HART 7 specification
Dual input temperature field transmitter
with HART® protocol and SIL3 certificationTechnical Information (TI) -
iTEMP TMT162
Temperature field transmitter
FOUNDATION Fieldbus™ or PROFIBUS® PA protocolTechnical Information (TI) -
ReadWin® Quick Setup
Operating Manual
ReadWin® Quick Setup Temperature
PC SoftwareOperating Instruction (BA) -
Temperature field transmitter iTEMP TMT162
Dual input transmitter
with FOUNDATION Fieldbus™ protocolOperating Instruction (BA) -
Temperature field transmitter iTEMP TMT162
Dual input transmitter with PROFIBUS PA® Protocol
Operating Instruction (BA) -
Operating Manuals ReadWin 2000 (GB)
Operating Manuals ReadWin 2000
Operating Instruction (BA) -
Temperature field transmitter iTEMP TMT162, HART 7 specification
Dual input temperature field transmitter with
HART® protocol and SIL3 certificationOperating Instruction (BA) -
Temperature field transmitter iTEMP TMT162, HART 5 specification
Dual input temperature field transmitter
Operating Instruction (BA) -
iTEMP TMT162
Temperature field transmitter with HART® protocol (revision 7.6)
and SIL 2/3 certificationShort Instruction (KA)08/17German , English -
iTEMP TMT162
Dual-input temperature field transmitter with FOUNDATION Fieldbus™
protocolShort Instruction (KA)06/15German , English -
iTEMP TMT162
Dual-input temperature field transmitter with PROFIBUS® PA protocol
Short Instruction (KA)04/18German , English -
Installation of overvoltage protection module
TMT162, HART 7 - overvoltage protection module as accessory
Installation Instructions (EA) -
Temperature transmitter
iTEMP TMT142, TMT162
0Ex ia IIC T6...T4 Ga X
1Ex d IIC T6...T4 Gb X
Ex tb IIIC T85°C...T105°C XEx Safety Instructions (XA) -
Control Drawing FM IS, NI, XP, DIP, iTEMP TMT162 HART 7
Surge protector, safety instructions for installation
Ex Safety Instructions (XA) -
TMT162, HART 7 specification
ATEX:
II1G Ex ia IIC Ga
II2D Ex ia IIIC Db
IECEx:
Ex ia IIC Ga
Ex ia IIIC Db
Safety instructions for electrical apparatus certified for use in
explosion-hazardous areas.Ex Safety Instructions (XA) -
TMT162
ATEX:
II2D Ex tb IIIC T110 °C Db
IECEx:
Ex tb IIIC T110 °C Db
Safety instructions for electrical apparatus certified for use in
explosion-hazardous areas.Ex Safety Instructions (XA) -
TMT162, HART protocol
ATEX: II1G Ex ia IIC
IECEx: Ex ia IIC
Safety instructions for electrical apparatus certified for use in
explosion-hazardous areas.Ex Safety Instructions (XA) -
ATEX II1/2GD EEx ia
TMT162 FF/PA
Safety instructions for electrical apparatus certified for use in
explosion-hazardous areas.Ex Safety Instructions (XA) -
ATEX Safety instructions iTEMP® HART® TMT162 (II2G EEx d)
ATEX Safety instructions for Temperature field transmitter iTEMP® HART®
TMT162 (Intrinsical safety II2G EEx d)Ex Safety Instructions (XA) -
iTEMP TMT162
ATEX IEC Installation types
II2G Ex d IIC T6…T4 Gb
II1G Ex ia IIC T6…T4 GaEx Safety Instructions (XA) -
Safety instructions ATEX II 1G (EEx ia)
iTEMP TMT162 FOUNDATION Fieldbus or PROFIBUS PA
Safety instructions for electrical apparatus certified for use in
explosion-hazardous areas.Ex Safety Instructions (XA) -
Safety instructions ATEX II 1/2D or 2D
iTEMP TMT162 FOUNDATION Fieldbus or PROFIBUS PA
Safety instructions for electrical apparatus certified for use in
explosion-hazardous areas.Ex Safety Instructions (XA) -
ATEX/IECEx Safety instructions for overvoltage protector installation
Safety instructions for electrical apparatus certified for use in
explosion-hazardous areas.
Installation in temperature field transmitters TMT162Ex Safety Instructions (XA) -
TMT162
ATEX:
II1G Ex ia IIC Ga
II2D Ex ia IIIC Db
IECEx:
Ex ia IIC Ga
Ex ia IIIC Db
Safety Instructions
Safety instructions for electrical apparatus certified for use in
explosion-hazardous areas.Ex Safety Instructions (XA) -
Control Drawing CSA Explosion Proof iTEMP TMT162, HART 7 specification
Temperature field transmitter
Installation Notes for hazardous locations
(Explosion Proof, Dust Ignition Proof and Non-Incendive)Ex Safety Instructions (XA) -
TMT162
ATEX:
II1G Ex ia IIC
IECEx:
Ex ia IIC
Safety Instructions
Safety instructions for electrical apparatus certified for use in
explosion-hazardous areas.Ex Safety Instructions (XA) -
iTEMP TMT162, TMT142
ATEX:
II 3G: Ex nA IIC T6...T4 Gc
Safety Instructions
Safety instructions for electrical apparatus certified for use in
explosion-hazardous areas.Ex Safety Instructions (XA) -
iTEMP TMT162
ATEX:
II 3G: Ex ic IIC T6...T4 Gc
Safety Instructions
Safety instructions for electrical apparatus certified for use in
explosion-hazardous areas.Ex Safety Instructions (XA) -
Control Drawing CSA IS, NI iTEMP TMT162 HART 7 specification
Temperature field transmitter
Installation notes for hazardous locations
(Intrinsically safe and Non-incendive)Ex Safety Instructions (XA) -
Safety instructions ATEX II 1/2G or 2G
iTEMP TMT162 FOUNDATION Fieldbus or PROFIBUS PA
Safety instructions for electrical apparatus certified for use in
explosion-hazardous areas.Ex Safety Instructions (XA) -
Safety instructions ATEX II 1G (EEx ia) / 1/2G (EEx d) TMT162
FOUNDATION
Fieldbus or PROFIBUS PA
Safety instructions for electrical apparatus certified for use in
explosion-hazardous areas.Ex Safety Instructions (XA) -
TMT162
ATEX:
II2G Ex d IIC Gb
IECEx:
Ex d IIC Gb
Safety Instructions
Safety instructions for electrical apparatus certified for use in
explosion-hazardous areas.Ex Safety Instructions (XA) -
iTEMP® TMT162, iTEMP TMT142
IECEx Certificate of Conformity
Certificate (ZE) -
Control Drawing FM XP, NI iTEMP® TMT162 FF/PA
Temperature field transmitter iTEMP® HART TMT162 FF/PA
Installation Notes for hazardous locationsCertificate FM/CSA (ZD) -
Control Drawing FM Explosion Proof iTEMP® TMT162
Temperature field transmitter iTEMP® HART TMT162
Installation Notes for hazardous locations
(Explosion Proof and Dust Ignition Proof)Certificate FM/CSA (ZD) -
Control Drawing CSA XP, NI iTEMP® TMT162 FF/PA
Temperature field transmitter iTEMP® HART TMT162 FF/PA
Installation Notes for hazardous locationsCertificate FM/CSA (ZD) -
Control Drawing CSA Intrinsical Safety, Nonincendive iTEMP® TMT162
Temperature field transmitter iTEMP® HART TMT162
Installation Notes for hazardous locationsCertificate FM/CSA (ZD) -
Control Drawing FM XP, NI iTEMP® TMT162
Temperature field transmitter iTEMP® HART TMT162
Installation Notes for hazardous locationsCertificate FM/CSA (ZD) -
Control Drawing CSA IS, NI iTEMP® TMT162 FF/PA
Temperature field transmitter iTEMP® HART TMT162 FF/PA
Installation Notes for hazardous locationsCertificate FM/CSA (ZD) -
Control Drawing FM IS, NI iTEMP® TMT162
Temperature field transmitter iTEMP® HART TMT162
Installation Notes for hazardous locationsCertificate FM/CSA (ZD) -
Control Drawing CSA Explosion Proof iTEMP® TMT162
Temperature field transmitter iTEMP® HART TMT162
Installation Notes for hazardous locations
(Explosion Proof and Dust Ignition Proof)Certificate FM/CSA (ZD) -
Control Drawing FM IS, NI iTEMP® TMT162 FF/PA
Temperature field transmitter iTEMP® HART TMT162 FF/PA
Installation Notes for hazardous locationsCertificate FM/CSA (ZD) -
Interoperability Statement: TMT162, FOUNDATION fieldbus
Endress+Hauser field device has been tested with Rockwell Automation
Integrated Architecture-based host system Allen-Bradley ControlLogix.
TMT162, FOUNDATION fieldbus Temperature Transmitter, Device Revision: 1,
DD Revision: 2, Device ID: 0x10CC, Software Revision: 1.00Special Documentation (SD) -
Temperature field transmitter iTEMP TMT162, HART 7 specification
Functional Safety Manual (SIL 2/3)
Special Documentation (SD) -
iTEMP TMT162
Temperature field transmitter, HART 5 specification
Functional safety manual (SIL)Special Documentation (SD) -
iTEMP TMT162
Manufacturer information for users regarding firmware updates (NE53)
FOUNDATION Fieldbus™ temperature field transmitter,
New firm-/software version: 02.00.13Manufacturer Information (MI) -
PRM FOUNDATION fieldbus Package V1.05.00
Manufacturer Information includes PRM - Device List, Release Notes –
FOUNDATION fieldbus
Manufacturer Information for users regarding software updates
(following the NAMUR recommendation 53)
New software version: 1.05.00Manufacturer Information (MI) -
iTEMP TMT162
Manufacturer information for users regarding firmware and hardware
updates (NE53)
Support HART 7 protocol
Status according to NE107
SIL 2/3 certification according to IEC 61508:2010
Integrated overvoltage protection (optional)
Display: Numbers black, background whiteManufacturer Information (MI) -
AMS FOUNDATION fieldbus Package V1.06.00
Manufacturer Information includes AMS - Device List, Release Notes –
FOUNDATION fieldbus
Manufacturer Information for users regarding software updates
(following the NAMUR recommendation 53)
New software version: 1.06.00Manufacturer Information (MI) -
AMS HART Package V1.12.00
Manufacturer Information includes AMS - Device List, Release Notes –
HART
Manufacturer Information for users regarding software updates
(following the NAMUR recommendation 53)
New software version: 1.12.00Manufacturer Information (MI) -
Manufacturer information software version 1.03.xx
New Firm-/Software version 1.03.xx for TMT162 HART field transmitter
Manufacturer Information (MI) -
Simatic PDM HART Package 1.14.00
Manufacturer Information includes PDM - Device List, Release Notes –
HART
Manufacturer Information for users regarding software updates
(following the NAMUR recommendation 53)
New software version: 1.14.00Manufacturer Information (MI) -
PRM HART Package V1.08.00
Manufacturer Information includes PRM - Device List, Release Notes –
HART
Manufacturer Information for users regarding software updates
(following the NAMUR recommendation 53)
New software version: 1.08.00Manufacturer Information (MI) -
Simatic PDM PROFIBUS Package V1.12.00
Manufacturer Information includes PDM - Device List, Release Notes –
PROFIBUS
Manufacturer Information for users regarding software updates
(following the NAMUR recommendation 53)
New software version: 1.12.00Manufacturer Information (MI) -
iTEMP TMT162
Manufacturer information for users regarding hardware updates (NE53)
Electronic components have been changed,
making a FW (xx.yy.zz) update at the zz position necessary.
The TMT162-xxxxxxxxx + 74 has NO SIL conformity.Manufacturer Information (MI) -
Temperature field transmitter
iTEMP® HART® TMT162
WIB Evaluation Report: E 2755 T 05
Publications (PU)07/05English -
High temperature measurement using Type R and B thermocouple connected
to a TMT162 transmitter.
In an incinerator, there is a need for optimized temperature measurement
in order to maintain high production. The use of the TMT162 temperature
transmitter ensures maximum performance at a lower cost to the customer.Industry Solutions (SO)06/10us , English -
Mesure de température
Capteurs et transmetteurs pour les industries de process
Fields of Activities (FA)12/19fr -
温度测量
过程工业用温度传感器和温度变送器
Fields of Activities (FA)12/14Chinese -
Pomiar temperatury
Czujniki i przetworniki pomiarowe
do kontroli przemysłowych procesów technologicznychFields of Activities (FA)10/14Polish -
Измерение температуры
Датчики температуры и преобразователи для любых
отраслей промышленности.Fields of Activities (FA)06/13Russian -
Misura della temperatura
Termometri e trasmettitori
per l'industria di processoFields of Activities (FA)04/18Italian -
Catálogo medición temperatura
Termómetros y transmisores para la industria de proceso
Fields of Activities (FA)04/18Spanish -
Sıcaklık Ölçümü
Proses endüstrisi için termometreler ve transmiterler
Fields of Activities (FA)03/13Turkish -
Field of activities FA Temperature measurement
Thermometers and transmitters for the process industry
Fields of Activities (FA)03/13English -
Temperature measurement
Thermometers and transmitters for the process industry
Fields of Activities (FA)02/20English -
Temperaturmesstechnik
Thermometer und Transmitter für die Prozessindustrie
Fields of Activities (FA)02/20German -
Измерение температуры
Ключевые особенности термометров Endress+Hauser для нефтегазовой отрасли
Competence Brochure (CP)08/11Russian -
Инженерные решения по термометрии
Специальные решения по термометрии для химической и
нефтеперерабатывающей промышленностиCompetence Brochure (CP)04/10Russian -
Control room temperature monitoring
TMT162 transmitter with bright blue background is ideal in low-light
control areasCase Studies (CS)10/07English -
Chemical plant uses 350 temperature transmitters
Field and head temperature transmitters used in global chemical company
in their production processes.Case Studies (CS)10/07English -
TMT162 with separate housing measures temperature
TMT162 with thermowell and separate housing monitors and controls
temperature in power plantCase Studies (CS)07/10English -
TMT162 a new choice for use in flash coolers and heat exchangers
CS0621 Temperature Field Transmitter
iTemp® TMT162 temperature transmitter, highest reliability in hars
industrial environmentsCase Studies (CS)07/08English -
TMT162, TH15 or TH13 and RN221N with Mercury in Glass (MIG) thermometer
replacement.
FDA proposes to allow the use of alternative temperature indicating
devices for processing low-acid canned foods.Case Studies (CS)06/10English -
Increased productivity and Throughput
Elimination of waste, batch rework and losses with innovative active
backup on RTD assemblies with transmittersCase Studies (CS)06/10English -
RTD with mini Tri-clamp reduces dead leg
TH18 fits into small spaces and minimizes dead legs in hygenic ferrules
Case Studies (CS)06/10English -
Temperature measurement in incinerators with dual sensor input
Type R and B thermocouple is connnected to a TMT162 transmitter used for
accuracy and reliability in high temperature measurementCase Studies (CS)06/10English -
Accurate temperature control of sub-cooled processes
TMT162 SMART transmitter provides instantaneous switching of elements,
ensuring highest accuracy and linearityCase Studies (CS)06/10English -
FDA proposes to allow the use of alternative temperature indicating
devices
TMT162, TH15 and RN221N with Mercury in Glass (MIG) Thermometer
Replacement for processing low-acid canned foodsCase Studies (CS)01/10English -
Temperature control in freeze drying
TMT162 temperature transmitters maintain accurate control in freeze
drying processCase Studies (CS)01/10English -
iTEMP TMT 162 Temperature Transmitter via
FOUNDATION fieldbus to the PlantPAx Process Automation System
System using a 1757-FFLD or FFLDC
Integration DocumentSystem Partner (SP)03/12English -
iTEMP TMT182 Head Transmitter via HART to the PlantPAx Process
Automation System
System using a ControlLogix 1756 HART Analog Input Module
Integration DocumentSystem Partner (SP)01/09English -
iTEMP TMT162 Field Transmitter via HART to the PlantPAx Process
Automation System
System using a ControlLogix 1756 HART Analog Input Module
Integration DocumentSystem Partner (SP)01/09English -
GSD Single, GSD_EH_PA_TE_iTEMP_0x1549_0x02_0x01_PALIB, 14.04.2014 (Temper
ature, iTEMP, 0x1549)
PROFIBUS PA,
PROFIBUS System Version: AnyGeneral Station Description (GSD)1.01.00Language neutral -
GSD Single, GSD_EH_PA_TE_iTEMP_0x1549_V01_00_06_PALIB, 14.04.2014 (Temper
ature, iTEMP, 0x1549)
PROFIBUS PA,
PROFIBUS System Version: AnyGeneral Station Description (GSD)1.00.00Language neutral -
EDD Single, EH_FF_TE_TMT162_0x10CC_0x02_0x02, 07.04.2014 (Temperature, iTEMP, 0x10CC)
FOUNDATION Fieldbus H1,
FOUNDATION fieldbus System Version: AnyElectronic Data Description (EDD)1.01.00Language neutral -
EDD Single, PDM_HART_TE_TMT162_0x11CE_0x04_0x01, 29.07.2019 (Temperature, iTEMP, 0x11CE)
HART,
PDM Version: 8.2.1, 9.0.1.2Electronic Data Description (EDD)1.00.01Language neutral -
EDD Single, EDD_FF_TE_iTEMP_0x10CC_0x03_0x03, 07.10.2015 (Temperature, iT
EMP)
FOUNDATION Fieldbus H1,
FOUNDATION fieldbus System Version: AnyElectronic Data Description (EDD)1.00.00Language neutral -
EDD Single, AMS12_0_HART_TMT162_0x11CE_0x04_0x01, 24.08.2018 (Temperature, iTEMP, 0x11CE)
HART,
AMS Version: 12.0, 12.5, 13.0, 13.1, 13.5Electronic Data Description (EDD)1.00.00Language neutral -
EDD Single, AMS11_0_FF_TE_iTEMP_0x10CC_0x03_0x04, 11.04.2017 (Temperature, iTEMP, 0x10CC)
FOUNDATION Fieldbus H1,
AMS Version: 11.0Electronic Data Description (EDD)1.00.00Language neutral -
EDD Single, PDM_PA_TE_iTEMP_TMT162_0x1549_0x02_0x02, 18.01.2019 (Temperature, iTEMP, 0x1549)
PROFIBUS PA,
PDM Version: 6.0 SP5, 6.1, 8.1 SP 1Electronic Data Description (EDD)1.00.00Language neutral -
EDD Single, PDM_HART_TE_iTEMP_TMT162_0x00CA_0x02_0x03, 07.11.2018 (Temperature, iTEMP, 0x00CA)
HART,
PDM Version: 6.0 SP5Electronic Data Description (EDD)1.00.00Language neutral -
EDD Single, EH_FF_TE_TMT162_10CC_0x01_0x03, 07.04.2014 (Temperature, iTEMP, 0x10CC)
FOUNDATION Fieldbus H1,
FOUNDATION fieldbus System Version: AnyElectronic Data Description (EDD)1.00.00Language neutral -
EDD Single, PDM_HART_TE_iTEMP_TMT162_0x00CA_0x01_0x01, 07.11.2018 (Temperature, iTEMP, 0x00CA)
HART,
PDM Version: 6.0 SP5Electronic Data Description (EDD)1.00.00Language neutral -
EDD Single, PDM_PA_TE_iTEMP_TMT162_0x1549_0x01_0x02, 18.01.2019 (Temperature, iTEMP, 0x1549)
PROFIBUS PA,
PDM Version: 6.0 SP5Electronic Data Description (EDD)1.00.00Language neutral -
EDD Single, AMS13_0_FF_TE_iTEMP_0x10CC_0x03_0x04, 11.04.2017 (Temperature, iTEMP, 0x10CC)
FOUNDATION Fieldbus H1,
AMS Version: 13.0Electronic Data Description (EDD)1.00.00Language neutral -
EDD Single, AMS10_0_FF_TE_iTEMP_0x10CC_0x03_0x04, 11.04.2017 (Temperature, iTEMP, 0x10CC)
FOUNDATION Fieldbus H1,
AMS Version: 10.0Electronic Data Description (EDD)1.00.00Language neutral -
EDD Single, AMS12_0_FF_TE_iTEMP_0x10CC_0x03_0x04, 11.04.2017 (Temperature, iTEMP, 0x10CC)
FOUNDATION Fieldbus H1,
AMS Version: 12.0Electronic Data Description (EDD)1.00.00Language neutral -
DTM Single, iTEMP_TMT162_FF_V1_00_xx_DevRev1, 22.10.2020 (Temperature, iTEMP, 0x10CC)
FOUNDATION Fieldbus H1,
DeviceCare Version: 1.07.00
Field Xpert - SMT70 Version: 1.05.00
FieldCare Version: 2.15.00Device Type Manager (DTM)1.6.55.40Language neutral -
DTM Single, iTEMP_TMT162_FF_FW1_01_zz_Dev_Rev_2, 22.10.2020 (Temperature, iTEMP, 0x10CC)
FOUNDATION Fieldbus H1,
DeviceCare Version: 1.07.00
Field Xpert - SMT70 Version: 1.05.00
FieldCare Version: 2.15.00Device Type Manager (DTM)1.6.55.40Language neutral -
DTM Single, iTEMP_TMT162_FF_FW2_00_zz_Dev_Rev_3, 22.10.2020 (Temperature, iTEMP, 0x10CC)
FOUNDATION Fieldbus H1,
ArchestrA IDE Version: 4.0.04001
DeviceCare Version: 1.07.00
Field Device Manager Version: R430.1
Field Xpert - SMT70 Version: 1.05.00
FieldCare Version: 2.15.00
Plant Resource Manager Version: R3.12Device Type Manager (DTM)1.6.55.40Language neutral -
DTM Single, iTEMP_TMT162_PA_FW1_01_zz_Dev_Rev_2, 21.10.2020 (Temperature, iTEMP, 0x1549)
PROFIBUS PA,
DeviceCare Version: 1.07.00
Field Xpert - SMT70 Version: 1.05.00
FieldCare Version: 2.15.00Device Type Manager (DTM)1.5.153.348Language neutral -
DTM Single, iTEMP_TMT162_PA_V1_0, 21.10.2020 (Temperature, iTEMP, 0x1549)
PROFIBUS PA,
DeviceCare Version: 1.07.00
Field Xpert - SMT70 Version: 1.05.00
FieldCare Version: 2.15.00Device Type Manager (DTM)1.5.153.348Language neutral -
DTM Single, iTemp_TMT162_V1_00_00___1_02_00, 26.10.2020 (Temperature, iTEMP, 0x00CA)
HART,
DeviceCare Version: 1.07.00
Field Xpert - SMT70 Version: 1.05.00
FieldCare Version: 2.15.00Device Type Manager (DTM)1.4.188.39Language neutral -
DTM Single, iTemp_TMT162_V1_03_00, 26.10.2020 (Temperature, iTEMP, 0x00CA)
HART,
DeviceCare Version: 1.07.00
Field Xpert - SMT70 Version: 1.05.00
FieldCare Version: 2.15.00Device Type Manager (DTM)1.4.188.39Language neutral -
DTM Single, ITEMP_TMT162_HART_FW_4_01_zz_Dev_Rev_04, 27.10.2020 (Temperature, iTEMP, 0x11CE)
HART,
ArchestrA IDE Version: 4.0.04001
DeviceCare Version: 1.07.00
Field Device Manager Version: R450.1
Field Xpert - SMT70 Version: 1.05.00
FieldCare Version: 2.15.00
PACTware Version: 5.0 SP4
Plant Resource Manager Version: R3.31Device Type Manager (DTM)1.13.132.5451Language neutral -
Faceplate Library, PRM_HART_Package_Temp_1_08_00, 03.12.2015 (Temperature)
HART,
Plant Resource Manager Version: R3.05, R3.11Faceplate1.08.00Language neutral -
Faceplate Library, PRM_FF_Package_Temp_1_05_00, 22.07.2015 (Temperature)
FOUNDATION Fieldbus H1,
Plant Resource Manager Version: R3.02Faceplate1.05.00Language neutral -
Faceplate Single, PRM_FF_TE_iTEMP_0x10CC_0x03_0x03, 07.10.2015 (Temperatu
re, iTEMP)
FOUNDATION Fieldbus H1,
Plant Resource Manager Version: R3.11Faceplate1.00.00Language neutral -
Field transmitter
Product Code: TMT162-
Declaration Number: HE_00460_01.17
Manufacturer Specification: RoHSManufacturer DeclarationEnglish -
DIN Rail Transmitter, Field transmitter, head transmitters, Process RTD Direct contact, Process RTD General purpose, Process RTD Heavy duty, Process RTD Hygienic, Process TC direct in contact, Process TC General purpose, Process TC Heavy duty
Product Code: TST310-, TSC310-, TPC100-, TMT162-, TMT142-, TMT128-, TMT127-, TMT122-, TMT121-, TMT112-, TMT111-
Declaration Number: HE_00237_04.15
Manufacturer Specification: Explosion protection, EMCManufacturer DeclarationRussian -
ACCESSORIES, DIN Rail Transmitter, Field transmitter, head transmitters
Product Code: TMT127-, TMT128-, TMT142-, TMT162-, TMT180-, TMT180L-, TMT181-, TMT181L-, TMT182-, TMT182L-, TMT187-, TMT188-, TMT80-, TMT82-, TMT84-, TMT85-, OTMT127-, OTMT128-, OTMT187-, OTMT188-, OTMT80-, OTMT82-, OTMT84-, OTMT85-, TID10-, TMT111L-, TMT112-, TMT112L-, TMT121-, TMT121L-, TMT122-, TMT125-
Declaration Number: EC_00567_01.17EU DeclarationGerman , English , fr -
Field transmitter
Product Code: TMT142-, TMT162-
Declaration Number: EC_00649_01.18EU DeclarationGerman , English , fr -
Field transmitter
Product Code: TMT142-, TMT162-, TMT142B-
Declaration Number: EC_00164_02.16EU DeclarationGerman , English , fr -
Field transmitter
Product Code: TMT162-
Declaration Number: EC_00605_01.17EU DeclarationGerman , English , fr -
Field transmitter
Product Code: TMT142B-, TMT162-
Declaration Number: EC_00605_02.17EU DeclarationGerman , English , fr -
Field transmitter
Product Code: TMT142-, TMT162-, TMT142B-
Declaration Number: EC_00100_01.15EU DeclarationGerman , English , fr -
Field transmitter
Product Code: TMT162-
Declaration Number: SIL_00221_02.17SIL DeclarationEnglish -
Field transmitter
Product Code: TMT162-
Declaration Number: SIL_00220_02.17SIL DeclarationGerman -
ACCESSORIES: RTD INSERT, ACCESSORIES: TC INSERT, ACCESSORIES: T_INSERTS, DIN Rail Transmitter, Field transmitter, head transmitters, Process RTD Direct contact, Process RTD General purpose
Product Code: TMT188-, TMT71-, TMT72-, TMT80-, TMT82-, TMT84-, TMT85-, TPC100-, TPC300-, TS111-, TS211-, TST310-, TST602-, TMT187-, TMT182-, TMT181-, TMT180-, TMT162-, TMT142B-, TMT142-, TMT128-, TMT127-, TMT122-, TMT121-, TMT112-, TMT111-, TET300-
Region/Country: Russia (TR CU)
Approval Agency: EAC
Approval Number: EAEC N RU D-DE.AB53.B.01191/20MiscellaneousRussian -
Field transmitter
Product Code: TMT142-, TMT162-
Region/Country: China
Approval Agency: ACMA
Approval Number: MD-17040A/09/ENMiscellaneousEnglish -
DIN Rail Transmitter, Process TC Heavy duty, Field transmitter, head transmitters, RTD-thermometer, Process RTD Heavy duty, process displays, power supply and barrier, contactors / transmitters
Product Code: TMT85-, TMT162R-, TMT162C-, TMT162-, TMT82-, TMT84-, TMT80-, TMT188-, TMT187-, TMT182-, TMT181-, TMT180-, TMT142-, TMT128-, TMT127-, TMT122-, TMT121-, TMT112-, TMT111-, TTR35-, TTR31-, TMT142R-, TMT142C-, TMR31-, TMR35-
Region/Country: Russia (TR CU)
Approval Agency: EAC
Approval Number: TC № RU D-DE.AG95.B.00650MiscellaneousRussian -
Field transmitter
Product Code: TMT142-, TMT162-
Region/Country: South Korea
Approval Agency: KOSHA
Protection: Ex ia IIC T6...T4Explosion Protection -
Field transmitter
Product Code: TMT162-
Region/Country: China
Approval Agency: NEPSI
Protection: Ex d IIC T6...T4 GbExplosion ProtectionChinese -
Process TC Heavy duty, Process TC General purpose, Process TC direct in contact, Process TC Direct contact, Process RTD Hygienic, Process RTD Heavy duty, Process RTD General purpose, Process RTD Direct contact, process displays, head transmitters, Field transmitter, ACCESSORIES: TC INSERT, ACCESSORIES: RTD INSERT
Product Code: TMT85-, TPC100-, TPR100-, TR10-, TR11-, TR12-, TR13-, TR15-, TR24-, TR45-, TR47-, TR61-, TR62-, TR63-, TR65-, TR66-, TR88-, TSC310-, TST310-, TMT84-, TMT82-, TMT162-, TMT142-, TEC420-, TC88-, TC66-, TC65-, TC63-, TC62-, TC61-, TC15-, TC13-, TC12-, TC10-, RID16-, RID14-, RIA16-, RIA15-, RIA14-
Region/Country: India
Approval Agency: NAGPUR
Protection: Ex ia IIC T6...T1, Ex ia IIC T6...T4, Ex ib IIC T6...T4Explosion ProtectionEnglish -
Field transmitter
Product Code: TMT142-, TMT162-
Region/Country: USA
Approval Agency: FM
Category: I,II,III/1,2/A,B,C,D,E,F,G/
Protection: XP, NI, IS, DIPExplosion ProtectionEnglish -
Field transmitter
Product Code: TMT162-
Region/Country: China
Approval Agency: NEPSI
Protection: Ex ia IIC T6...T4 Ga/GbExplosion ProtectionChinese -
Field transmitter
Product Code: TMT142-, TMT142B-, TMT162-
Region/Country: International (IECEx)
Approval Agency: KEMA
Protection: Ex tb IIIC Txxx°C Db, Ex db IIC T6...T4 GbExplosion ProtectionEnglish -
Field transmitter
Product Code: TMT142B-, TMT162-
Region/Country: International (IECEx)
Approval Agency: Bureau Veritas
Protection: Ex ia IIC T6...T4 Ga, Ex ia IIIC Txxx°C DbExplosion ProtectionEnglish -
Field transmitter
Product Code: TMT162-
Region/Country: China
Approval Agency: NEPSI
Protection: Ex nA IIC T6...T4 GcExplosion ProtectionChinese -
Field transmitter
Product Code: TMT142-, TMT142B-, TMT162-
Region/Country: Europe (ATEX)
Approval Agency: KEMA
Category: II 2 G, II 2 D
Protection: Ex db IIC T6...T4 Gb, Ex tb IIIC Txxx°C DbExplosion ProtectionEnglish -
Field transmitter
Product Code: TMT142-, TMT162-
Region/Country: International, International (IECEx)
Approval Agency: KEMA
Protection: Ex ia IIIC Txxx°C Db, Ex ia IIC T6...T4 GaExplosion ProtectionEnglish -
Field transmitter
Product Code: TMT142B-, TMT162-
Region/Country: Europe (ATEX)
Approval Agency: Bureau Veritas
Category: II 2 D, II 1 G
Protection: Ex ia IIC T6...T4 Ga, Ex ia IIIC Txxx°C DbExplosion ProtectionGerman , English -
Field transmitter
Product Code: TMT142-, TMT162-
Region/Country: Canada, USA
Approval Agency: CSA
Category: I,II,III/1,2/A,B,C,D,E,F,G/
Protection: DIP, IS, NI, XPExplosion ProtectionEnglish -
Field transmitter
Product Code: TMT142-, TMT162-
Region/Country: Europe (ATEX)
Approval Agency: DEKRA
Category: II 2 D, II 1 G
Protection: Ex ia IIC T6...T4 Ga, Ex ia IIIC Txxx°C DbExplosion ProtectionEnglish -
Field transmitter
Product Code: TMT142-, TMT162-
Region/Country: South Korea
Approval Agency: KOSHA
Protection: Ex d IIC T6...T4Explosion Protection -
DIN Rail Transmitter, Field transmitter, head transmitters
Product Code: TMT85-, TMT84-, TMT82-, TMT188-, TMT187-, TMT182-, TMT181-, TMT162-, TMT142-, TMT128-, TMT127-, TMT122-, TMT121-, TMT112-, TMT111-
Protection: [Ex ia Ga] IIC T6...T4 Gb, Ex d IIC T6...T4 Ga, Ex d IIC T6...T4 Ga/Gb, Ex d IIC T6...T4 Gb, Ex ia IIC T6...T4 Ga, Ex tb IIIC Txxx°C GbExplosion ProtectionRussian -
Product Family: Field transmitter
Product Code: TMT162-
Region/Country: International
Approval Agency: Fieldbus Foundation
Software Version: DEVICE REV. 02, DD-ITK 5.20Fieldbus ConformanceEnglish -
Product Family: Field transmitter
Product Code: TMT162-
Region/Country: International
Approval Agency: Fieldbus Foundation
Software Version: DEVICE REV. 01, DD-ITK 4.61Fieldbus ConformanceEnglish -
Field transmitter
Product Code: TMT162-
Region/Country: International
Approval Agency: PI, PROFIBUS International
Software Version: PROFILE 3.02Fieldbus ConformanceEnglish -
Product Family: Field transmitter
Product Code: TMT162-
Region/Country: International
Approval Agency: Fieldbus Foundation
Software Version: DEVICE REV. 02, DD-ITK 5.20Fieldbus ConformanceEnglish -
DIN Rail Transmitter, head transmitters, Field transmitter
Product Code: TMT85-, TMT162-, TMT82-, TMT84-, TMT80-, TMT188-, TMT187-, TMT182-, TMT181-, TMT180-, TMT142-, TMT128-, TMT127-, TMT121-, TMT112-, TMT122-, TMT111-
Region/Country: Russia
Approval Agency: Rosstandart
Approval Number: OC.C.32.004.A NO 74639MetrologyRussian -
Field transmitter
Product Code: TMT162-
Region/Country: International
Approval Agency: TÜVSafety Integrity Level (SIL)English -
Field transmitter, Process RTD Heavy duty
Product Code: TMT162-, TMT162R-
Region/Country: International
Approval Agency: BVMarineEnglish -
Field transmitter, Process RTD Heavy duty
Product Code: TMT162-, TMT162R-
Region/Country: South Korea
Approval Agency: KRMarineEnglish -
Field transmitter, Process RTD Heavy duty
Product Code: TMT162-, TMT162R-
Region/Country: International
Approval Agency: DNVGLMarineEnglish -
Field transmitter
Product Code: TMT162-
Region/Country: International
Approval Agency: LRMarineEnglish -
Field transmitter, Process RTD Heavy duty
Product Code: TMT162-, TMT162R-
Region/Country: International
Approval Agency: ABSMarineEnglish -
RTD-thermometer, head transmitters, DIN Rail Transmitter, process displays, Memo-Graph, Field transmitter, Ecograph, contactors / transmitters
Product Code: TMT85-, TMT162-, TMT142-, RIA14-, RIA16-, RIA45-, RIA46-, RMA42-, RSG35-, RSG45-, TMR31-, TMR35-, TMT84-, TMT82-, TMT188-, TMT187-, TMT182-, TMT181-, TMT128-, TMT127-, TMT122-, TMT121-, TMT112-, TMT180-, TMT111-, TTR35-, TTR31-, RSG40-
Region/Country: Canada, USA
Approval Agency: ULOrdinary Location Product SafetyEnglish
Accessories / Spare parts
-
-
Order code 51004823
Mount.bracket st.steel A4 wall/tube 2"
-
-
-
Nr 8 Order code 51004653
-
Nr 8 Order code 51004654
-
-
-
Order code 51004915
Adapter M20x1.5 exter./M24x1.5 intern.VA
-
-
-
Nr 8 Order code 51004949
Cable entry M20x1.5
-
-
-
Order code 51006412
Mounting bracket 2"tube stainless steel
-
-
-
Nr 8 Order code 51006845
Cable gland NPT1/2, D4.5-8.5 IP68
-
-
-
Nr 2 Order code 71310423
-
-
-
Order code 71386275
Integrable Surge Arrester Module
for subsequent mounting in field transmitter. Ensure compatibility.
-
-
-
Nr 6 Order code 71439499
O-Ring 88x3 HNBR 70° Shore PTFE-coated
-
-
-
Nr 7 Order code 51004948
-
-
-
Nr 5 Order code TMT162X-HA
Housing cover blind, 316L Exd ATEX Ex d, FM XP + O-ring CSA XP only as cover of terminal part
-
Nr 5 Order code TMT162X-HB
Housing cover blind, 316L + O-ring
-
Nr 5 Order code TMT162X-HC
Housing cover cpl. for display,Ex d,316L ATEX Ex d, FM XP, CSA XP + O-ring
-
Nr 5 Order code TMT162X-HD
Housing cover cpl. for display, 316L + O-Ring
-
Nr 5 Order code TMT162X-HH
Housing cover blind, Alu Ex d FM XP + O-ring CSA XP only as cover of terminal part
-
Nr 5 Order code TMT162X-HI
Housing cover blind, Alu + O-ring
-
Nr 5 Order code TMT162X-HK
Housing cover cpl. for display,Alu Ex d + O-ring
-
Nr 5 Order code TMT162X-HL
Housing cover cpl. for display, Alu + O-ring
-
-
-
Nr 2 Order code TMT162X-DA
Display HART5 + fitting kit + twist protection
-
Nr 2 Order code TMT162X-DB
Display PA/FF + fitting kit + twist protection
-
Nr 2 Order code TMT162X-DC
Display fitting kit + twist protection
-
Nr 2 Order code TMT162X-DD
Display HART7 + fitting kit + twist protection
-
-
-
Nr 8 Order code 51004489
Blanks (blind) M20x1.5 EEx-d/XP
-
Nr 8 Order code 51004490
Blanks (blind) NPT1/2, 3.1655.53
-
Nr 8 Order code 51004916
Blanks (blind) G1/2" Ex-d/XP
-
Nr 8 Order code 51006888
Blanks (blind) 1/2NPT V4A
-
-
-
Order code 71079762
Fieldbus connector PA M20;M12 L250
-
Order code 71079763
Fieldbus connector PA 1/2NPT; M12 L250
-
Order code 71079765
Fieldbus connector PA M20;7/8" L250
-
Order code 71082008
Fieldbus connector FF M20;7/8" L250
-
Order code 71082009
Fieldbus connector FF 1/2NPT;7/8" L250
-
Order code DIENST-
Service
-
Order code XPRFID-
-
-
-
Nr 4 Order code TMT162E-
Electronic TMT162
-
-
-
Nr 1 Order code TMT162G-
Housing TMT162
-
-
-
Order code TMT162X-HE
Housing cover blind, T17 316L
-
Order code TMT162X-HF
Housing cover cpl. for display, T17,316L polycarbonate
-
-
Predecessor