Seminar
iTHERM TM412
Imperial Hygienic Thermometer,
US style
For use in hygienic and aseptic applications in the Food & Beverages and Life Sciences industries
It has been designed to meet the requirements of the Food & Beverages and Life Sciences industries and complies with the highest quality standards. It offers a variety of versions within a clearly segmented standard product. The result: Time and cost savings by simple and fast product selection. It offers many technical innovations: iTHERM QuickSens, StrongSens or QuickNeck. This leads to distinctive reduction of maintenance costs, improved product quality, process efficiency and safety.
- F
- L
- E
- X
-
Standard products
- Reliable, robust and low-maintenance
Technical excellence
Simplicity
-
Specialized products
- Designed for demanding applications
Technical excellence
Simplicity
Variable
FLEX selections | Technical excellence | Simplicity |
---|---|---|
Fundamental selection Meet your basic measurement needs |
Technical excellence
|
Simplicity
|
Lean selection Handle your core processes easily |
Technical excellence
|
Simplicity
|
Extended selection Optimize your processes with innovative technologies |
Technical excellence
|
Simplicity
|
Xpert selection Master your most challenging applications |
Technical excellence
|
Simplicity
Variable |
-
Specs at a glance
-
Accuracy
class B acc. to IEC 60751
class A acc. to IEC 60751
class AA acc. to IEC 60751 -
Response time
depending on configuration
QuickSens: t90 = 1,5 s
StrongSens: t90 = 9,5 s -
Max. process pressure (static)
at 20 °C: 40 bar (580 psi)
-
Operating temperature range
PT100 WW:
-200 °C … 600 °C
(-328 °F … 1.112 °F)
StrongSens:
-50 °C … 500 °C
(-58 °F … 932 °F)
QuickSens:
-50 °C … 200 °C
(-58 °F … 392 °F)
PT100 TF:
-50 °C … 200 °C -
Max. immersion length on request
48"
-
Quick selection
Individual configuration
-
Benefits
-
User-friendly and reliable from product selection to maintenance
-
iTHERM inserts: globally unique, fully-automated production. Full traceability and consistently high product quality for reliable measured values
-
iTHERM QuickSens: fastest response times...
-
-
Field of application
Specially designed for use in hygienic and aseptic applications in the Food & Beverages and Life Sciences industries
Measuring range: –200 to +600 °C (–28 to +1 112 °F)
Pressure range up to 40 bar (580 psi)
Protection class: up to IP69K
Documents / Manuals / Software
-
iTHERM TM412
Technical Information
Hygienic, modular resistance thermometer
Technical Information (TI) -
Modular hygienic thermometers
Universal modular thermometers with RTD insert for hygienic applications
Operating Instruction (BA) -
Installation Instructions
iTHERM TM402, TM412
Imperial hygienic RTD thermometer
Installation Instructions (EA) -
TM411, TM412
Control Drawing
FM IS, NIEx Safety Instructions (XA) -
Omnigrad TRxx, TCxx, TxCxxx
RTD/TC modular thermometers
0Ех ia IIC T6…T1 Ga Х
Ga/Gb Ех ia IIC T6…T1 Ga Х
Ех ia IIIC 85 °C…450 °C Da Х
Ех ia IIIC 85 °C…450 °C Da/Db ХEx Safety Instructions (XA) -
RTD/TC thermometers
ATEX II 3G, II 3D
Safety Instructions
Safety instructions for electrical apparatus certified for use in
explosion-hazardous areas.Ex Safety Instructions (XA) -
TR1x, TR4x, TR88, TSC310, TST310, TR6x, TC1x, TC6x, TC88, TPC100,
TPR100, TM411, TM412, TR24
Thermometers and inserts
Ex iaIIC T1-T6 Ga, Ex iaD 20 T85-T450Ex Safety Instructions (XA) -
TM411
TM412
CSA IS, NI
Control DrawingEx Safety Instructions (XA) -
Modular RTD assemblies for hygienic applications
iTHERM TM411, TM412
ATEX: II 1/2D Ex ta/tb IIIC T85 °C...T450 °C Da/Db
IECEx: Ex ta/tb IIIC T85 °C...T450 °C Da/Db
DEKRA 12ATEX0085; IECEx DEK 12.0019Ex Safety Instructions (XA) -
iTHERM TS111, TM211
Omniset TPx100, Omnigrad TSx310
RTD/TC inserts and cable thermometers
ATEX:
II1D, II1/2D Ex ia IIIC or II1G, II1/2G Ex ia IIC
IECEx:
Ex ia IIC Ga, Ga/Gb
Safety instructions for electrical apparatus certified for use in
explosion-hazardous areas.Ex Safety Instructions (XA) -
iTHERM® TM411, TM412
ATEX: II 1D, II 1/2D Ex ia IIIC or II 1G, II 1/2G Ex ia IIC
IECEx: Ex ia IIIC, Ex ia IIC
DEKRA 12ATEX0161 X; IECEx DEK 12.0049 X
Safety Instructions
Modular RTD assemblies for hygienic applications
Ex Safety Instructions (XA) -
TRxx, TCxx, TS211, iTHERM TS111, TM211, TPx100, TSx310, TM1x1, TM411,
TM412
Thermometers and inserts
Ex nA IIC T6...T1 GcEx Safety Instructions (XA) -
Misura della temperatura e componenti di sistema per i settori
alimentare e
farmaceutico.
Misura della temperatura e componenti di sistema per i settori
alimentare e
farmaceutico.
La nuova frontiera dell'igiene: un'offerta complete per applicazioni
igieniche e asettichePublications (PU)01/20Italian -
iTHERM Thermometer
TM401, TM402, TM411, TM412
Modulare iTHERM Thermometer im hygienegerechten Design für die
Lebensmittel- und pharmazeutische IndustrieInnovations (IN)08/17German -
iTHERM thermometers
TM401, TM402, TM411, TM412
Modular iTHERM thermometers with hygienic design
for the Food & Beverage and Life Sciences industriesInnovations (IN)08/17English -
iTHERM® TM411
Новое поколение термометров для пищевой и фармацевтической
промышленностиInnovations (IN)04/12Russian -
iTHERM®
TM401, TM402, TM411, TM412
Sondes de température modulaires hygiéniques iTHERM® dédiées aux
industries agroalimentaires et pharmaceutiquesInnovations (IN)01/13fr -
ACCESSORIES: PIPE THERMOWELL, ACCESSORIES: T_INSERTS, Process RTD Hygienic, RTD-thermometer
Product Code: TK40-, TM371-, TM372-, TM401-, TM402-, TM411-, TM412-, TMR35-, TS111-, TS212-, TT411-, TT412-
Declaration Number: HE_00886_01.17Manufacturer DeclarationGerman , English -
Process RTD Hygienic
Product Code: TM412-
Declaration Number: HE_01263_01.20
Manufacturer Specification: RoHSManufacturer DeclarationChinese -
ACCESSORIES: PIPE THERMOWELL, ACCESSORIES: T_INSERTS, Process RTD Hygienic, RTD-thermometer
Product Code: TK40-, TM371-, TM372-, TM401-, TM402-, TM411-, TM412-, TMR35-, TS111-, TS212-, TT411-, TT412-
Declaration Number: HE_00886_02.17Manufacturer DeclarationGerman , English -
Process RTD Hygienic
Product Code: TK40-, TM401-, TM402-, TM411-, TM412-, TS111-, TS112-, TT411-, TT412-
Declaration Number: MD-12028A-9Manufacturer DeclarationEnglish -
ACCESSORIES: PIPE THERMOWELL, Magphant, Process RTD Hygienic, RTD-thermometer
Product Code: TTR35-, TT412-, TT411-, TMR35-, TM412-, TM411-, TM402-, TM401-, TM372-, TM371-, TM311-, TK40-, DTT35-
Declaration Number: HE_01097_01.19
Manufacturer Specification: Food hygieneManufacturer DeclarationEnglish -
ACCESSORIES: PIPE THERMOWELL, Magphant, Process RTD Hygienic, RTD-thermometer
Product Code: TTR35-, TT412-, TT411-, TMR35-, TM412-, TM411-, TM402-, TM401-, TM372-, TM371-, TM311-, TK40-, DTT35-
Declaration Number: FDA_00127_03.17FDA DeclarationGerman , English -
Process TC Heavy duty, Process TC General purpose, Process TC direct in contact, Process TC Direct contact, Process RTD Hygienic, Process RTD Heavy duty, Process RTD General purpose, Process RTD Direct contact, ACCESSORIES: T_INSERTS, ACCESSORIES: TC INSERT, ACCESSORIES: RTD INSERT
Product Code: TR11-, TR12-, TR13-, TR15-, TR24-, TR25-, TR45-, TR47-, TR61-, TR62-, TR63-, TR65-, TR66-, TR88-, TS111-, TSC310-, TST310-, TR10-, TC10-, TC12-, TC13-, TC15-, TC61-, TC62-, TC63-, TC65-, TC66-, TC88-, TEC420-, TM111-, TM131-, TM411-, TM412-, TPC100-, TPR100-
Declaration Number: EC_00169_02.16EU DeclarationGerman , English , fr -
Process RTD General purpose, Process TC General purpose, Process RTD Hygienic, Process RTD Heavy duty, Process RTD Direct contact, Process TC Heavy duty, Process TC direct in contact, ACCESSORIES: RTD INSERT, ACCESSORIES: TC INSERT, ACCESSORIES: T_INSERTS
Product Code: TC10-, TC12-, TC13-, TR11-, TR12-, TR13-, TR15-, TR24-, TM411-, TM412-, TR10-, TR45-, TR47-, TR88-, TR66-, TR65-, TR63-, TR62-, TR61-, TST310-, TC15-, TC88-, TC66-, TC65-, TC63-, TC62-, TC61-, TSC310-, TPR100-, TPC100-, TS111-
Declaration Number: EC_00177_01.16EU DeclarationGerman , English , fr -
ACCESSORIES: RTD INSERT, ACCESSORIES: TC INSERT, ACCESSORIES: T_INSERTS, Process RTD Direct contact, Process RTD General purpose, Process RTD Heavy duty, Process RTD Hygienic, Process TC direct in contact, Process TC General purpose, Process TC Heavy duty
Product Code: TR12-, TR13-, TR15-, TR24-, TR45-, TR47-, TR61-, TR62-, TR63-, TR65-, TR66-, TR88-, TS111-, TSC310-, TST310-, TR11-, TR10-, TPR100-, TPC100-, TM412-, TM411-, TC88-, TC66-, TC65-, TC63-, TC62-, TC61-, TC15-, TC13-, TC12-, TC10-
Declaration Number: EC_00177_02.16EU DeclarationGerman , English , fr -
Process TC Heavy duty, Process TC General purpose, Process TC Direct contact, Process RTD Hygienic, Process RTD Heavy duty, Process RTD General purpose, Process RTD Direct contact, Low cost RTD General purpose
Product Code: TM412-, TR10-, TR11-, TR12-, TR13-, TR15-, TR24-, TR25-, TR44-, TR45-, TR46-, TR47-, TR48-, TR61-, TR62-, TR63-, TR65-, TR66-, TR88-, TST40N-, TST41N-, TST434-, TM411-, TAF11-, TAF12D-, TAF12S-, TAF12T-, TAF16-, TC10-, TC12-, TC13-, TC15-, TC61-, TC62-, TC63-, TC65-, TC66-, TC88-, TEC420-, TM101-, TM111-, TM121-, TM131-, TM401-, TM402-
Declaration Number: EC_00136_02.16EU DeclarationGerman , English -
Process RTD Hygienic
Product Code: TM411-, TM412-
Region/Country: International (IECEx)
Approval Agency: DEKRA
Category: DA/DB
Protection: Ex ta/tb IIIC T85°C...T450°CExplosion ProtectionEnglish -
Process RTD Hygienic
Product Code: TM411-, TM412-
Region/Country: USA
Approval Agency: FM
Category: I/2/A,B,C,D/T, I/1/A,B,C,D/T, II,III/1/E,F,G/T
Protection: DIP, IS, NIExplosion ProtectionEnglish -
Process RTD Hygienic
Product Code: TM411-, TM412-
Region/Country: China
Approval Agency: NEPSI
Protection: Ex ia IIC T6...T1 Ga, Ex ia IIC T6...T1 Ga/GbExplosion ProtectionEnglish -
Process RTD General purpose, Process RTD Hygienic
Product Code: TM111-, TM131-, TM411-, TM412-
Region/Country: Canada, USA
Approval Agency: CSA
Category: I/2/A,B,C,D, I/1/A,B,C,D T6...T4, II,III/1/E,F,G, I/zone 1, I/zone 0
Protection: Ex ia IIC T6...T4 Ga, AEx ia IIC T6...T4 Ga, AEx/Ex [AEx/Ex ia] IIC T6...T4 GbExplosion ProtectionEnglish -
ACCESSORIES: PIPE THERMOWELL, Magphant, Process RTD Hygienic, RTD-thermometer
Product Code: TTR35-, TT412-, TT411-, TMR35-, TM412-, TM411-, TM402-, TM401-, TM372-, TM371-, TM311-, TK40-, DTT35-
Region/Country: Europe
Approval Agency: TU MünchenHygienic EquipmentEnglish -
ACCESSORIES: PIPE THERMOWELL, Magphant, Process RTD Hygienic, RTD-thermometer
Product Code: TTR35-, TT412-, TT411-, TMR35-, TM412-, TM411-, TM402-, TM401-, TM372-, TM371-, TM311-, TK40-, TE411-, DTT35-
Region/Country: Canada, USA
Approval Agency: 3-A Sanitary StandardsHygienic EquipmentEnglish -
ACCESSORIES: PIPE THERMOWELL, Process RTD Hygienic
Product Code: TT411-, TT412-, TM411-, TM412-
Region/Country: Canada (CRN)
Approval Agency: CRNPressure EquipmentEnglish -
Process RTD Explosion proof, Process RTD General purpose, Process RTD Hygienic, Process TC Explosion proof
Product Code: T13-, T14-, T15-, T53-, T54-, T55-, TM111-, TM131-, TM411-, TM412-
Region/Country: USA, Canada
Approval Agency: CSAOrdinary Location Product SafetyEnglish -
Process RTD General purpose, Process RTD Hygienic
Product Code: TM111-, TM131-, TM411-, TM412-
Region/Country: Canada, USA
Approval Agency: CSAOrdinary Location Product SafetyEnglish
Accessories / Spare parts
-
-
Order code 52018765
Weld-in adapter G3/4 d=50, 316L, 3.1
Flush mount process connection Material: 316L. Inspection cert. EN10204-3.1 material. Seal: silicone O-ring. FDA, EHEDG, 3-A compliant. Usage: FMI51, FTI51, FTL20/FTL20H, FTL31/FTL33, FTW23/FTW33, QMW43, 11371. Usage: TMR35.
-
Order code 52021717
O-ring 14.9x2.7 VMQ, FDA, 5 pcs.
Material: silicone VMQ 75. Usage: Weld-in adapter G3/4, 316L, (71258355) vesselmounting, (71258357) pipe-mounting, flush mount, FTL31/FTL33, FTW23/FTW33, QMW43, Weld-in adapter G3/4, 316L, 3.1, (52018765) vesselmounting, (52028295) pipe-mounting, flush mount, FMI51, FTI51, FTL31/FTL33, FTW23/FTW33, QMW43.
-
Order code 52028295
Weld-in adapter G3/4, d=29, 316L, 3.1
Flush mount process connection. For pipe-mounting. Material: 316L. Inspection cert. EN10204-3.1 material. Seal: silicone O-ring. FDA, EHEDG compliant. Usage: FTL20/FTL20H, FTL31/FTL33, FTW23/FTW33, QMW43.
-
Order code 52001052
Weld-in adapter G3/4, d=55, 316L
Flush mount process connection. Material: 316L. Seal: silicone O-ring. FDA, EHEDG, 3-A compliant. Usage: FTL50/FTL50H, FTL80, QMW43. Usage: TMR35.
-
Order code 52011897
Weld-in adapter G3/4, 316L, 3.1
Flush mount process connection. Material: 316L. Inspection cert. EN10204-3.1 material. Seal: silicone O-ring. FDA, EHEDG, 3-A compliant. Usage: FTL50/FTL50H, FTL80, QMW43. Usage: TMR35.
-
Order code 52014473
O-ring 21.89x2.62 VMQ, FDA, 5 pcs.
Material: silicone VMQ 70. Usage: weld-in adapter G3/4, 316L (52001052) flush mount, 316L, 3.1 (52011897) flush mount, FTL50/FTL50H/FTL51/FTL51H, FTL80/FTL81.
-
Order code 52001051
Weld-in adapter G1, d=60, 316L
Flush mount process connection. Material: 316L. Seal: silicone O-ring. FDA, EHEDG, 3-A compliant. Usage: FMI51/FMI52, FTI51/FTI52, FTL20/FTL20H, FTL31/FTL33, FTL50/FTL50H/FTL51/FTL51C/FTL51H, FTL80/FTL81, FTL260, FTW23, FTW33, PMP23, PMP51, PMP135, PTP33B/PTP35, QMW43. Usage: TM401/TM411, TMR35.
-
Order code 52011896
Weld-in adapter G1, d=60, 316L, 3.1
Flush mount process connection. Material: 316L. Inspection cert. EN10204-3.1 material. Seal: silicone O-ring. FDA, EHEDG, 3-A compliant. Usage: FMI51/FMI52, FTI51/FTI52, FTL20H, FTL31/FTL33, FTL50/FTL50H/FTL51/FTL51C/FTL51H, FTL80/FTL81, FTL260, FTW23, FTW33, PMP23, PMP51, PMP135, PTP33B/PTP35, QMW43. Usage: TM401/TM411, TMR35.
-
Order code 71093129
Weld-in adapter G1, d=53, 316L, 3.1
Flush mount process connection. Material: 316L. Inspection cert. EN10204-3.1 material Seal: silicone O-ring FDA, EHEDG, 3-A compliant. Usage: FMI51/FMI52, FTI51/FTI52, FTL20H, FTL31/FTL33, FTL50/FTL50H/FTL51/FTL51C/FTL51H, FTL80/FTL81, FTL260, FTL330H/FTL330L, FTW23, FTW33, PMP135, PTP35, QMW43.
-
Order code 52014472
O-ring 28.17x3.53 VMQ, FDA, 5 pcs.
Material: silicone VMQ 70. Usage: weld-in adapter G1, 316L, (52001051) flush mount, FMI51/FMI52, FTI51/FTI52, FTL31/FTL33, FTW23/FTW33, PMP23, PMP51, PTP33B, FTL50/FTL50H/FTL51/FTL51H, FTL80/FTL81, QMW43, Weld-in adapter G1, 316L, 3.1, (52011896) flush mount, FMI51/FMI52, FTI51/FTI52, FTL31/FTL33, FTW23/FTW33, PMP23, PMP51, PTP33B, FTL50/FTL50H/FTL51/FTL51H, FTL80/FTL81,QMW43, sliding sleeve FTM21.
-
Order code 52001221
Weld-in adapter G1, adjustable, 316L
Flush mount process connection. Material: 316L. Liquiphant is adjustable. Seal: silicone profile gasket. FDA, EHEDG, 3-A compliant. Usage: FTL20/FTL20H, FTL31/FTL33, FTL50/FTL50H/FTL51/FTL51C/FTL51H, FTL80/FTL81, FTL330H/330L.
-
Order code 52011898
Weld-in adapter G1, adjustable,316L, 3.1
Flush mount process connection. Material: 316L. Liquiphant is adjustable. Inspection cert. EN10204-3.1 material. Seal: silicone profile gasket. FDA, EHEDG, 3-A compliant. Usage: FTL20/FTL20H, FTL50/FTL50H/FTL51/FTL51C/FTL51H, FTL31/FTL33, FTL80/FTL81, FTL330H/FTL330L.
-
Order code 52014424
Profile gasket 29x36x3.7, FDA, 5 pcs.
Material: silicone VMQ. Usage: Process connect. G1 flush mount, Weld-in adapter G1, 316L, adjustable (52001221), Weld-in adapter G1, 316L, 3.1, adjustable (52011898), FTL31/FTL33, FTL80/FTL81, FTL50/FTL50H/FTL51/FTL51H, Weld-in adapter Rd52, 316L, adjustable, (52001047), 316L, 3.1, adjustable, (52006909), FTL33, FTL50/FTL50H/FTL51/FTL51H, QMW43.
-
Order code 71275424
Grip cap flexible yellow TPE
-
Order code 51516983
Commubox FXA291 (Hardware)
Serial USB Computer Interface Technical Data: - USB Version1.1 or higher - Power supply via USB - IP51; NEMA/Typ 3 - Ambient temperature: -20....+60oC - Ex: II(2) G (EEx ia) II C - ATEX: BVS 05 ATEX E 095 Scope of deliovery: Commubox FXA 291 MS Windows USB driver Device is submitted for CSA/FM application. The device may not be modified and may be used with intrinsically safe circuits with corresponding characteristics only (see safety certificate).
-
Order code TMT71-
iTEMP TMT71, Transmitter 4-20mA
2-wire temperature transmitter. Single universal sensor input. Galvanic isolation 2kV (input/output). Application: RTD, TC, Ohm and mV. Factory setup w/o additional specification:Pt100, 4-wire, 0...+100oC.
-
Order code TMT72-
iTEMP TMT72, Transmitter HART
2-wire temperature transmitter. Single universal sensor input. Galvanic isolation 2kV (input/output). Application: RTD, TC, Ohm and mV. Factory setup w/o additional specification:Pt100, 4-wire, 0...+100oC.
-
Order code TS212-
Insert imperial iTHERM TS212
Insert replaceable central spring load imperial version ::Fastest response times for optimal process control through iTHERM QuickSens insert. ::Maximum robustness for highest process safety through iTHERM StrongSens insert. Maximum RTD accuracy at high temperature through iTHERM HotSens insert.
-
Order code TT412-
iTHERM TT412 Thermowell
Thermowell with hygienic design. Imperial version for applications in the food/beverages and pharmaceutical industries.
-
Order code TMT162-
iTEMP TMT162, Field Transmitter
Temperature transmitter. Application: RTD, TC, Ohm, mV. HART, PROFIBUS PA Profile 3.02 or FOUNDATION Fieldbus separately available. Galvanic isolation 2 kV (sensor input/output). NEMA Type 4X Encl., IP67. Dual compartment. DNV GL marine approval (only HART). UL listed.
-
Order code TMT180-
iTEMP TMT180, Head Transmitter Pt100
Temperature transmitter,PC-programable. Application: RTD. 2-wire 4-20mA. Fault reaction: NAMUR NE 43. Mounting: head form B, DIN EN50446. UL listed.
-
Order code TMT181-
iTEMP TMT181, Head Transmitter PCP
Product being phased out, limited availability. Temperature transmitter,PC-programmable. Application: RTD, TC, Ohm, mV. 2-wire 4-20mA, galvanic isolation. Fault reaction: NAMUR NE 43. Mounting: head form B, DIN EN50446. UL listed.
-
Order code TMT84-
iTEMP TMT84, Transmitter PA
Dual sensor input. Advanced diagnostics:sensor monitoring. PROFIBUS PA Profile 3.02. Galvanic isolation 2kV. Application: RTD, TC, Ohm, mV. Current consumption: 11 mA. Mounting: head form B, DIN EN50446. Factory setup: CH1: Pt100, 3-wire, oC. CH2: inactive. Differing configuration optional selectable.
-
Order code TMT85-
iTEMP TMT85, Transmitter FF
Dual sensor input. Advanced diagnostics: sensor monitoring. FOUNDATION Fieldbus protocol Galvanic isolation 2 kV. Application: RTC, TC, Ohm, mV. Current consumption: 11 mA. Mounting: head form B, DIN EN50446. Factory setup: CH1: Pt100, 3-wire, oC. CH2: inactive. Differing configuration optional selectable.
-
Order code TID10-
Display Unit Head Transmitter
to plug on. Dot-Matrix measured value display. 12 DIP-switches buttom side. Settings: FF: Simulation, Write Lock. PA: Bus address, Write Lock. Compatible: TMT85, TMT84, TMT82.
-
Order code XPT0004-
-
Order code TA30A-
Terminal Head TA30A
Retainer for terminal block or head transmitter + optional display. Cover: low, hinged, optional window. Material: aluminium. Coating: polyester powder-coating. Colour: body blue, cover grey. Ambient temp.: -50...150 oC (housing). Protection: IP66/68, NEMA 4X (housing).
-
Order code TA30D-
Terminal Head TA30D
Retainer for 2 head transmitters or terminal blocks. Cover: high, hinged. Material: aluminium. Coating: polyester powder-coating. Colour: body blue, cover grey. Ambient temp.: -50...150 oC (housing). Protection: IP66/68, NEMA 4X (housing).
-
Order code TA30P-
Terminal Head TA30P
Retainer for 2 head transmitters or terminal blocks. Cover: high, hinged. Material: Polyamid PA12 antistatic. Colour: black. Ambient temp.: -40...120oC (housing). Protection: IP65 (housing).
-
Order code TA30R-
Terminal Head TA30R
Retainer for terminal block or head transmitter + optional display. Cover: screwed, optional window. Material: Stainless Steel 316L. Colour: Steel (no coating). Ambient Temp.: -50...85/130 oC (display/standard). Protection: IP66/68, NEMA4X; IP69K (housing). :: easy wiring through best accessibility. :: compact desing and low weight.
-
Order code TA30S-
Terminal Head TA30S
Retainer for terminal block or head transmitter. Cover: screwed. Material: Polypropylene. Colour: white. Ambient Temperature: -30...+130oC. Protection: IP65, NEMA4X (housing). :: easy wiring through good accessibility. :: compact design, low weight.
-
Order code TMT182-
iTEMP TMT182, Head Transmitter HART
Product being phased out, limited availability. Temperature transmitter, Protocol HART. Application: RTD, TC, Ohm, mV. 2-wire 4-20mA, galvanicisolation. Fault reaction: NAMUR NE 43. Mounting: head form B, DIN EN50446. UL listed.
-
Order code TMT82-
iTEMP TMT82, Transmitter HART
2-wire temperature transmitter. Dual universal sensor input. Galvanic isolation 2kV (input/output). Application: RTD, TC, Ohm and mV. ::Highly reliable due to drift detection and sensor back up. ::Optional also for safety critical applications by means of SIL 2/3 acc. to IEC61508.
-
Order code FXA195-
Commubox FXA195
Modem to connect HART field devices to a computer via USB. Commissioning of field devices with software tool. :: To connect to a intrinsically safe signal circuit. :: SIL2, IEC61508.
-
Order code TXU10-
Configuration Kit TXU10
for PC-programmable devices. set-up programme+interface cable for PC with USB-Port.
-
Order code SFE500-
FieldCare SFE500
FieldCare is a software tool based on FDT/DTM technology. FieldCare is scalable which allows to fulfill tasks from Device Setup, Plant Asset Management or Condition Monitoring (Asset Health Monitoring). FieldCare includes approved Endress+Hauser and third party DTM Libraries and can be used with W@M Life-Cycle Management. Additional hardware e.g. modems, or interfaces is needed. One year update service is included to guarantee top quality and performance. (Online application update or download from Endress+Hauser Software Portal)
-
Order code FXA42-
Fieldgate FXA42
Compact gateway for data capture of field devices, without antenna. Embedded web server, alarm / event handling. Application: remote monitoring, inventroy data monitoring, web enabled field interface. Field device interfaces 4-20mA, Modbus RTU, digital inputs/outputs. :: Meets NAMUR NE43 requirements. :: Data transition into SupplyCare.
-
Order code TM412-
iTHERM TM412
Modular,hygienic resistance thermometer. Imperial version with exchangeable insert for applications in the food/ beverages and pharmaceutical industries. With thermowell. Measuring range: -328...+1.112oF/ -200...+600oC (depending on the configuration). :::Fastest response times for optimal process control through iTHERM QuickSens insert. ::Maximum robustness for highest process safety through iTHERM StrongSens insert. ::Cost savings with recalibrations through iTHERM QuickNeck coupling.
-
-
Predecessor