Specs at a glance
-
Max. measurement error
Volume flow (liquid): ±0.75 %
Volume flow (steam, gas): ±1.00 %
Mass flow (liquid): ±0.85%
Mass flow (steam, gas): ±1.7 % -
Measuring range
Liquid: 0.16 to 625 m³/h (0.09 to 368 ft³/min)
depending on medium: water with 1 bar a, 20 °C (14.5 psi a, 68° F)
Steam, gas: 2 to 8342 m³/h (1.18 to 4910 ft³/min)
depending on medium: steam with 180 °C, 10 bar a (356 °F, 145 psi a); air with 25 °C, 4.4 bar a (77 °F, 63.8 psi a) -
Medium temperature range
Standard: –40 to +260 °C (–40 to +500 °F)
High/low temperature (option): –200 to +400 °C (–328 to +752 °F)
High/low temperature (on request): –200 to +450 °C (–328 to +842 °F) -
Max. process pressure
PN 40, Class 300, 20K
-
Wetted materials
Measuring tube: 1.4408 (CF3M)
DSC sensor: 1.4435 (316/316L)
Field of application
The Prowirl D sensor can be installed directly between flanges and thus serves as the functional device for applications in ancillary processes at little installation cost. With genuine loop-powered technology, Prowirl D 200 enables cost-effective and seamless integration into existing infrastructures. It offers highest operational safety in hazardous areas. Heartbeat Technology enables process safety at all times.
Preferred measuring principle for wet/saturated/superheated steam, gases & liquids (also cryogenic)
For all basic applications and for 1-to-1 replacement of orifice plates.
Device properties
Face-to-face length of 65 mm (2.56 in)
No flanges
Low weight
Display module with data transfer function
Robust dual-compartment housing
Plant safety: worldwide approvals (SIL, Haz. area)
Benefits
Integrated temperature measurement for mass/energy flow of saturated steam
Easy alignment of the sensor – included centering rings
High availability – proven robustness, resistance to vibrations, temperature shocks & water hammer
Long-term stability – robust drift-free capacitive sensor
Convenient device wiring – separate connection compartment
Safe operation – no need to open the device due to display with touch control, background lighting
Integrated verification – Heartbeat Technology
Videos
Lean selection
-
Standard products
- Reliable, robust and low-maintenance
Technical excellence
Simplicity
-
Standard products
- Reliable, robust and low-maintenance
Technical excellence
Simplicity
-
Specialized products
- Designed for demanding applications
Technical excellence
Simplicity
Variable
FLEX selections | Technical excellence | Simplicity |
---|---|---|
Fundamental selection Meet your basic measurement needs |
Technical excellence
|
Simplicity
|
Lean selection Handle your core processes easily |
Technical excellence
|
Simplicity
|
Extended selection Optimize your processes with innovative technologies |
Technical excellence
|
Simplicity
|
Xpert selection Master your most challenging applications |
Technical excellence
|
Simplicity
Variable |
Predecessor
-
-
Technical Information (TI)
TI Proline Prowirl D 200
English version - 06/2024
Vortex flowmeter
EN 19/06/202421/06/202001/01/2018Language:
English
Version:
19/06/2024
File size:
4.9 MB
File name:
TI01332DEN_0323-00.pdf
-
-
-
Operating Instruction (BA)
Proline Prowirl D 200 HART
English version - 06/2020
Vortex flowmeter
EN 21/06/202001/01/2018Language:
English
Version:
21/06/2020
File size:
4.3 MB
File name:
BA01685DEN_0220.pdf
-
-
-
Technical Information (TI)
TI Proline Prowirl D 200
Vortex flowmeter
EN 19/06/202421/06/202001/01/2018Language:
English
Version:
19/06/2024
File size:
4.9 MB
File name:
TI01332DEN_0323-00.pdf
-
-
-
Operating Instruction (BA)
Proline Prowirl D 200 FOUNDATION Fieldbus
Vortex flowmeter
EN 21/06/202001/01/2018Language:
English
Version:
21/06/2020
File size:
5 MB
File name:
BA01693DEN_0220.pdf
-
-
-
Operating Instruction (BA)
Proline Prowirl D 200 HART
Vortex flowmeter
EN 21/06/202001/01/2018Language:
English
Version:
21/06/2020
File size:
4.3 MB
File name:
BA01685DEN_0220.pdf
-
-
-
Operating Instruction (BA)
Proline Prowirl D 200 PROFIBUS PA
Vortex flowmeter
EN 21/06/202001/01/2018Language:
English
Version:
21/06/2020
File size:
4.5 MB
File name:
BA01689DEN_0220.pdf
-
-
-
Operating Instruction (BA)
BA Proline Prowirl D 200
Vortex flowmeter
PROFINET with Ethernet-APLEN 19/06/2024Language:
English
Version:
19/06/2024
File size:
4.5 MB
File name:
BA02133DEN_0122-00.pdf
-
-
-
Device Parameter (GP)
Proline Prowirl 200 PROFIBUS PA Description of Device Parameters
Vortex flowmeter
EN 01/01/2018Language:
English
Version:
01/01/2018
File size:
1.8 MB
File name:
GP01110DEN_0118.pdf
-
-
-
Device Parameter (GP)
GP Proline Prowirl 200
Vortex flowmeter
PROFINET with Ethernet-APLEN 19/06/2024Language:
English
Version:
19/06/2024
File size:
1.6 MB
File name:
GP01170DEN_0122-00.pdf
-
-
-
Device Parameter (GP)
Proline Prowirl 200 HART Description of Device Parameters
Vortex flowmeter
EN 01/07/201901/01/2018Language:
English
Version:
01/07/2019
File size:
2.1 MB
File name:
GP01109DEN_0219.pdf
-
-
-
Device Parameter (GP)
Proline Prowirl 200 FOUNDATION Fieldbus Description of Device Parameters
Vortex flowmeter
EN 01/07/201901/01/2018Language:
English
Version:
01/07/2019
File size:
2.4 MB
File name:
GP01111DEN_0219.pdf
-
-
-
Short Instruction (KA)
Flowmeter Proline 200 Brief Operating Instructions
Profibus PA transmitter
with vortex flow sensorEN 03/12/201801/01/2018Language:
English
Version:
03/12/2018
File size:
1.7 MB
File name:
KA01328DEN_0218.pdf
-
-
-
Short Instruction (KA)
Flowmeter Proline 200 Brief Operating Instructions
HART transmitter
with vortex flow sensorEN 03/12/201801/01/2018Language:
English
Version:
03/12/2018
File size:
1.4 MB
File name:
KA01326DEN_0218.pdf
-
-
-
Short Instruction (KA)
KA Flowmeter Proline 200
Transmitter with vortex flow sensor
PROFINET with Ethernet-APLEN 19/06/2024Language:
English
Version:
19/06/2024
File size:
1.5 MB
File name:
KA01545DEN_0122-00.pdf
-
-
-
Short Instruction (KA)
Flowmeter Proline 200 Brief Operating Instructions
FOUNDATION Fieldbus transmitter
with vortex flow sensorEN 03/12/201801/01/2018Language:
English
Version:
03/12/2018
File size:
1.7 MB
File name:
KA01327DEN_0218.pdf
-
-
-
Short Instruction (KA)
Flowmeter Proline Prowirl D Brief Operating Instructions
Proline Prowirl D
Vortex flow sensorEN 03/12/201801/01/2018Language:
English
Version:
03/12/2018
File size:
673.8 KB
File name:
KA01322DEN_0218.pdf
-
-
-
Installation Instructions (EA)
EA Replacing the I/O-Module
Proline 200
EN 01/07/202301/10/201818/12/2013Language:
English
Version:
01/07/2023
File size:
633.9 KB
File name:
EA01092DA2_0323-00.pdf
-
-
-
Installation Instructions (EA)
Replacing the display module Installation Instructions
Promag 200, Promass 200, Prosonic Flow 200, Prowirl 200, t-mass 150,
Levelflex FMP5x, Micropilot FMR5x, Micropilot FMR6x, Remote dis
play FHX50EN 01/09/201701/02/201724/11/201528/11/201306/04/2012Language:
English
Version:
01/09/2017
File size:
562.2 KB
File name:
EA00102DA2_1817.pdf
-
-
-
Installation Instructions (EA)
Replacing the connection board, pre amplifier, cable harness Installation Instructions
Prowirl 200
EN 01/12/201702/12/2013Language:
English
Version:
01/12/2017
File size:
770.5 KB
File name:
EA01086DA2_0217.pdf
-
-
-
Installation Instructions (EA)
EA Conversion Kit for Prowirl 200 Compact Version to Prowirl 200 Remote Version
Prowirl 200 non explosion-protected
EN 16/10/202301/02/202203/03/202001/05/201723/04/2015Language:
English
Version:
16/10/2023
File size:
1.4 MB
File name:
EA01055DA2_0623-00.pdf
-
-
-
Installation Instructions (EA)
Alteration of the pressure measuring cell
Prowirl 200 Index C
EN 14/11/202201/06/202119/02/2021Language:
English
Version:
14/11/2022
File size:
664.1 KB
File name:
EA01332DA2_0322-00.pdf
-
-
-
Installation Instructions (EA)
Safety Instructions for Spare Parts Installation Instructions
Flowmeter
EN 01/03/201828/11/201325/04/2013Language:
English
Version:
01/03/2018
File size:
139.5 KB
File name:
EA01051DA2_0318.pdf
-