Proline Prosonic Flow
G 500 Ultrasonic flowmeter
Highly robust gas specialist for fluctuating process conditions as remote version with up to 4 I/Os
For a wide range of gas applications Prosonic Flow G provides reliable flow measurement, even with wet gas and changing gas properties and compositions. A pressure-rated sensor housing with rupture disc limits safety risks. The innovative remote transmitter maximizes installation flexibility and operational safety in demanding environments. Heartbeat Technology ensures compliance and process safety at all times.
- F
- L
- E
- X
-
Standard products
- Reliable, robust and low-maintenance
Technical excellence
Simplicity
-
Specialized products
- Designed for demanding applications
Technical excellence
Simplicity
Variable
FLEX selections | Technical excellence | Simplicity |
---|---|---|
Fundamental selection Meet your basic measurement needs |
Technical excellence
|
Simplicity
|
Lean selection Handle your core processes easily |
Technical excellence
|
Simplicity
|
Extended selection Optimize your processes with innovative technologies |
Technical excellence
|
Simplicity
|
Xpert selection Master your most challenging applications |
Technical excellence
|
Simplicity
Variable |
-
Specs at a glance
-
Max. measurement error
Volume flow (standard):
‐ ±1.0 % o.r. for 3 to 40 m/s (9.84 to 131.23 ft/s)
‐ ±2 % o.r. for 0.3 to 3 m/s (0.98 to 9.84 ft/s)
Volume flow (optional calibration):
‐ ±0.5 % o.r. for 3 to 40 m/s (9.84 to 131.23 ft/s)
‐ ±1.0 % o.r. for 0.3 to 3 m/s (0.98 to 9.84 ft/s)
Mass flow (standard):
‐ ±1.5 % o.r. for 3 to 40 m/s (9.84 to 131.23 ft/s)
‐ ±2.5 % o.r. for 0.3 to 3 m/s (0.98 to 9.84 ft/s)
Mass flow (optional calibration):
±1.0 % o.r. for 3 to 40 m/s (9.84 to 131.23 ft/s)
±1.5 % o.r. for 0.3 to 3 m/s (0.98 to 9.84 ft/s)
Methane content: ±1.00 %
Molar mass: ±1.50 %
Density: ±1.50 %
Dynamic viscosity: ±3.00 %
Heating value: ±1.00 %
Wobbeindex: ±1.00 % -
Measuring range
Gas: 0.3 m/s to 40 m/s
-
Medium temperature range
-50 to 150 °C (-58 to +302°F)
-50 to 100 °C (-58 to +212°F) with integrated pressure cell -
Max. process pressure
0.7 to 101 bar a (10.15 to 1464.88 psi a)
-
Wetted materials
Measuring tube: 1.4408/1.4409 (CF3M)
Transducer: 1.4404 (316, 316L, Titan Grade 2
-
Quick selection
Individual configuration
-
Benefits
Flexible device with user-definable gas mixtures for demanding measuring tasks
Maximum reliability even with humid or wet gas – sensor design insensitive to condensate
High-performance process control – real-time pressure- and temperature-compensated values
Efficient solution – multivariable, no pressure loss
Full access to process and...
-
Field of application
The measuring principle is unaffected by gas composition
Accurate measurement of natural and process gas in the chemical as well as oil and gas industries.
Device properties:
Direct measurement: flow, pressure & temperature
Wetted parts: titanium / 316L
...
Documents / Manuals / Software
-
Proline Prosonic Flow G 500
Technical Information
Ultrasonic time-of-flight flowmeter
Highly robust gas specialist for fluctuating process conditions as
remote version with up to 4I/OsTechnical Information (TI) -
Proline Prosonic Flow G 500
HART
Operating Instructions
Ultrasonic time-of-flight flowmeter
Operating Instruction (BA) -
Proline Prosonic Flow G 500
Modbus RS485
Operating Instructions
Ultrasonic time-of-flight flowmeter
Operating Instruction (BA) -
Proline Prosonic Flow 500
Modbus RS485
Description of Device Parameters
Ultrasonic time-of-flight flowmeter
Device Parameter (GP) -
Proline Prosonic Flow 500
HART
Description of Device Parameters
Ultrasonic time-of-flight flowmeter
Device Parameter (GP) -
Proline 500 – digital
HART
Brief Operating Instructions
Transmitter with ultrasonic time-of-flight sensor
Short Instruction (KA)08/19English -
Proline Prosonic Flow G
Brief Operating Instructions
Proline Prosonic Flow G
Ultrasonic time-of-flight sensorShort Instruction (KA)08/19English -
Proline 500 – digital
Modbus RS485
Brief Operating Instructions
Transmitter with ultrasonic time-of-flight sensor
Short Instruction (KA)08/19English -
Protective Cover connection compartment
Promag, Promass 300, 500, 500-digital, Prosonic Flow, t-mass 300,
500-digitalInstallation Instructions (EA) -
Alteration to Display module, to Display module with WirelessHART or
Display module with WLAN
Promag, Promass 300, 500, 500-digital, Prosonic Flow 300, 500-digital,
t-mass 300, 500-digitalInstallation Instructions (EA) -
Replacing the electronics
Promag, Promass 300, 500, 500-digital, Prosonic Flow, t-mass 300,
500-digitalInstallation Instructions (EA) -
Replacing the Display Protection
Promag 400 Index C, Promag, Promass, Prosonic Flow, t-mass 500-digital
Installation Instructions (EA) -
Pipe mounting set
Promag, Promass, Prosonic Flow, t-mass 500-digital
Installation Instructions (EA) -
Replacing ISEM electronics module, ISEM extender, ribbon cable
Promag, Promass 300, 500, 500-digital, Prosonic Flow, t-mass 300,
500-digitalInstallation Instructions (EA) -
Alteration pressure cell
Prosonic Flow 300, 500-digital
Installation Instructions (EA) -
Replacing cover, O-ring, seal housing for transmitter wall mounting and
seal housing for the sensor side
Promag, Promass 500, 500-digital, Prosonic Flow, t-mass 500-digital
Installation Instructions (EA) -
Replacing the Sensor
Promag, Promass, Prosonic Flow 500-digital
Installation Instructions (EA) -
Replacing the transmitter
Installation Instructions
Prosonic Flow 500-digital
Installation Instructions (EA) -
Replacing the Components for the Transmitter
Promag 400 Index C, Promag, Promass, Prosonic Flow, t-mass 500-digital
Installation Instructions (EA) -
Replacing Small parts
Promag, Promass 100, 500, CNG-, LNG-, LPGmass, Promag 400 Index C,
Prosonic Flow E 100, Prosonic Flow E Heat, Prosonic Flow, t-mass
500-digitalInstallation Instructions (EA) -
Replacing the sensor, gasket for sensor and the pressure cell
Prosonic Flow G 300, 500-digital
Installation Instructions (EA) -
Replacing the S-DAT
Installation Instructions
Promag, Promass 300, 500, 500-digital, Prosonic Flow 300, 500-digital,
t-mass 300, 500-digitalInstallation Instructions (EA) -
Weather Protection
Promag, Promass, Prosonic Flow, t-mass 500-digital
Installation Instructions (EA) -
Replacing Small Parts
Promag 400 , Promag 800 Index B, Cubemass, Promag 500, Promag, Promass,
Prosonic Flow, t-mass 500-digitalInstallation Instructions (EA) -
Replacing the display module
Promag, Promass 300, 500, 500-digital, Prosonic Flow, t-mass 300,
500-digital, DKX001–Installation Instructions (EA) -
Replacing Spare Parts
Promag, Promass 100, CNG-, LNG-, LPGmass, Promag 400 Index C, Proline
300, 500, 500-digital, Prosonic Flow E 100, Prosonic Flow E He
at, Prosonic Flow, t-mass 300, 500-digitalInstallation Instructions (EA) -
Kit wireless antenna for extended range
Promag, Promass 300, 500, 500-digital, Prosonic Flow 300, 500-digital,
t-mass 300, 500-digitalInstallation Instructions (EA) -
Replacing the terminal connection
Promag, Promass 300, 500, 500-digital, Prosonic Flow, t-mass 300,
500-digitalInstallation Instructions (EA) -
Activating application packages, switching the I/O function, upgrading
with additional I/O hardware
Promag, Promass 300, 500, 500-digital, Prosonic Flow 300, 500-digital,
t-mass 300, 500-digitalInstallation Instructions (EA) -
Replacing RJ45-M12 Adapter
Proline 300, 500-digital
Installation Instructions (EA) -
Replacement of parts for the sensor connection housing, remote version
Promag 400 Index C, Promag 500, Promag, Promass, Prosonic Flow, t-mass
500-digitalInstallation Instructions (EA) -
Proline Prosonic Flow 500
ATEX:
II2G
II2D
IECEx:
Zone 1
Zone 21Ex Safety Instructions (XA) -
Proline Prosonic Flow 500
INMETRO:
Zone 2Ex Safety Instructions (XA) -
Proline Prosonic Flow 500
NEPSI:
Zone 1
Zone 21Ex Safety Instructions (XA) -
Proline Prosonic Flow 500
Class I Zone 2
Class I Division 2Ex Safety Instructions (XA) -
Proline Prosonic Flow 500
NEPSI:
Zone 2Ex Safety Instructions (XA) -
Proline Prosonic Flow 500
ATEX:
II3G
IECEx:
Zone 2Ex Safety Instructions (XA) -
Proline Prosonic Flow 500
INMETRO:
Zone 0/1
Zone 1
Zone 2
Zone 21Ex Safety Instructions (XA) -
Proline Prosonic Flow 500
Cl.I, II, III Div.1 for XP
(Ex d Flameproofed version)Ex Safety Instructions (XA) -
Proline Prosonic Flow 500
JPN:
Zone 1
Zone 21Ex Safety Instructions (XA) -
Proline Prosonic Flow 500
Class I, Zone 1
Zone 21Ex Safety Instructions (XA) -
Proline Prosonic Flow 500
Functional Safety Manual
Special Documentation (SD) -
Proline Prosonic Flow 500
Modbus RS485
Web server
Special Documentation
Web server
Special Documentation (SD) -
Proline Prosonic Flow 500
HART
Heartbeat Verification + Monitoring application package
Special Documentation
Ultrasonic time-of-flight flowmeter
Special Documentation (SD) -
Proline Prosonic Flow 500
Modbus RS485
Advanced gas analysis application package
Special Documentation (SD) -
Display modules A309/A310
Display with WLAN interface
Special Documentation (SD) -
Proline Prosonic Flow 500
HART
Advanced gas analysis application package
Special Documentation
Ultrasonic time-of-flight flowmeter
Special Documentation (SD) -
Proline Prosonic Flow 500
HART
Web server
Special Documentation
Web server
Special Documentation (SD) -
Information on the Pressure Equipment Directive
Proline flowmeters
Special Documentation
Proline flowmeters
Special Documentation (SD) -
Proline Prosonic Flow 500
Modbus RS485
Heartbeat Verification + Monitoring application package
Special Documentation
Ultrasonic time-of-flight flowmeter
Special Documentation (SD) -
Proline Prosonic Flow G 300/500 (eBook – PC version)
Redéfinit la mesure des gaz de process
Competence Brochure (CP)06/19fr -
Proline Prosonic Flow G 300/500 (eBook – Tablet version)
Redefines process gas measurement
Competence Brochure (CP)06/19fr -
Proline Prosonic Flow G 300/500 (e-book – Tablet version)
Redefines process gas measurement
Competence Brochure (CP)04/20English -
Proline Prosonic Flow G 300/500 (e-book – PC version)
Redefines process gas measurement
Competence Brochure (CP)04/20English -
Proline Prosonic Flow G 300/500
Redéfinit la mesure des gaz de process
Innovations (IN)06/19fr -
Proline Prosonic Flow G 300/500
Ridefinisce la misura dei gas di processo
Innovations (IN)06/19Italian -
Proline Prosonic Flow G 300/500
Redefines process gas measurement
Innovations (IN)04/20English -
Proline Prosonic Flow G 300/500
Die Neudefinition der Prozessgasmessung
Innovations (IN)04/20German -
Prosonic Flow G500
Ultraschall-Durchflussmessgerät für Gase, getrennte Bauform, zur
kontinuierlichen
Erfassung des (Norm-)Volumenfluss sowie optional Gasanalyse, Druck und
TemperaturTender Text04/20German -
EDD Single, AMS11_HART_FL_ProsonicFlow300_0x115D_0x01_0x01, 16.01.2020 (Flow, Prosonic Flow 300 500
HART,
AMS Version: 11.0, 11.1, 11.5, 12.0Electronic Data Description (EDD)1.00.00Language neutral -
EDD Single, AMS12_HART_FL_ProsonicFlow300_0x115D_0x01_0x01, 16.01.2020 (Flow, Prosonic Flow 300 500
HART,
AMS Version: 12.0, 12.5, 13.0, 13.1, 13.5, 14.0, 14.1Electronic Data Description (EDD)1.00.00Language neutral -
EDD Single, PDM_HART_FL_ProsonicFlow300500_0x115D_0x01_0x01, 03.02.2020 (Flow, Prosonic Flow 300 50
HART,
PDM Version: 8.2.1, 9.1.0.4Electronic Data Description (EDD)1.00.00Language neutral -
EDD Single, FDM_HART_FL_ProsonicFlow300500_0x115D_0x01_0x01, 15.01.2020 (Flow, Prosonic Flow 300 50
HART,
Experion Version: R500
Field Device Manager Version: R500Electronic Data Description (EDD)1.00.00Language neutral -
DTM Single, ProsonicFlow_300500_HART_FW_1_00_zz_Dev_Rev_01, 06.11.2020 (Flow, Prosonic Flow 300 500
HART,
ArchestrA IDE Version: 4.0.04001
DeviceCare Version: 1.07.00
Field Device Manager Version: R500
Field Xpert - SMT70 Version: 1.05.00
FieldCare Version: 2.15.00
PACTware Version: 5.0
Plant Resource Manager Version: R3.31Device Type Manager (DTM)1.45.0.257Language neutral -
DTM Single, ProsonicFlow_300500_MR4-CDIE_FW_1_00_zz_Dev_Rev_01, 06.11.2020 (Flow, Prosonic Flow 300
Modbus RS485,
DeviceCare Version: 1.07.00
Field Xpert - SMT70 Version: 1.05.00
FieldCare Version: 2.15.00Device Type Manager (DTM)1.38.0.88Language neutral -
DTM Single, ProsonicFlow_300500_CDI_FW_1_00_zz_Dev_Rev_01, 06.11.2020 (Flow, Prosonic Flow 300 500,
Modbus RS485,
DeviceCare Version: 1.07.00
Field Xpert - SMT70 Version: 1.05.00
FieldCare Version: 2.15.00Device Type Manager (DTM)1.38.0.88Language neutral -
Faceplate Single, PRM_HART_FL_ProsonicFlow300500_0x115D_0x01_0x01, 15.01.2020 (Flow, Prosonic Flow
HART,
Plant Resource Manager Version: R3.31Faceplate1.00.00Language neutral -
Verification DTM Library, VerificationDTM_FLOW_Modbus_RS485, 15.05.2020 (Flow)
Modbus RS485,
DeviceCare Version: 1.06.00
FieldCare Version: 2.13.00Verification DTM1.06.05Language neutral -
Verification DTM Library, VerificationDTM_FLOW_HART, 15.05.2020 (Flow)
HART,
DeviceCare Version: 1.06.00
FieldCare Version: 2.13.00Verification DTM1.06.05Language neutral -
Prosonic Flow G
Product Code: 9G3B-, 9G5B-
Declaration Number: HE_01372_01.20
Manufacturer Specification: Heartbeat TechnologyManufacturer DeclarationGerman , English -
Prosonic Flow G
Product Code: 9G3B-, 9G5B-
Declaration Number: EC_00752_02.19EU DeclarationGerman , English , fr -
Prosonic Flow G
Product Code: 9G3B-, 9G5B-
Declaration Number: EC_00753_01.19EU DeclarationGerman , English , fr -
Prosonic Flow G
Product Code: 9G3B-, 9G5B-
Declaration Number: EC_00744_01.19EU DeclarationGerman , English , fr -
Prosonic Flow G
Product Code: 9G3B-, 9G5B-
Declaration Number: EC_00754_02.19EU DeclarationGerman , English , fr -
T-MASS I, T-MASS F, t-mass, PROSONIC FLOW P, Prosonic Flow G, LNGmass, Dosimass
Product Code: 65F-, 65I-, 6F3B-, 6F5B-, 6I3B-, 6I5B-, 8E-, 9G3B-, 9G5B-, 9P5B-, D8LB-
Region/Country: Russia (TR CU)
Approval Agency: EAC
Approval Number: EAEC N RU D-CH.AD07.B.02228/20MiscellaneousRussian -
Promass K, Promass O, Promass P, Promass Q, Promass S, Promass X, Prosonic Flow 91, Prosonic Flow 92, Prosonic Flow 93, Prosonic Flow G, Prowirl D, Prowirl F, Prowirl O, Prowirl R, t-mass, t-mass A, t-mass B, T-MASS F, T-MASS I, Promass I, CNGmass, Dosimag, Dosimass, LNGmass, LPGmass, Promag 10, Promag D, Promag E, Promag H, Promag L, Promag P, Promag W, Promass 40, Promass 80, Promass 83, Promass 84, Promass E, Promass F, Promass H
Product Code: 8I3B-, 8I1B-, 8H5B-, 8H3B-, 8F5B-, 8F3B-, 8F2B-, 8F1B-, 8E5B-, 8E3B-, 8E2C-, 8E2B-, 8E1C-, 8E1B-, 8E-, 84X-, 84F-, 83X-, 83F-, 80F-, 7R2C-, 8I5B-, 8K1B-, 8O3B-, 8O5B-, 8P1B-, 8P3B-, 8P5B-, 8Q3B-, 8Q5B-, 8S1B-, 8S1C-, 8S3B-, 8S5B-, 8X3B-, 8X5B-, 91W-, 92F-, 93C-, 93W-, 9G3B-, 9G5B-, DDA-, 7R2B-, 10D-, 10E-, 10H-, 10L-, 10P-, 10W-, 40E-, 5D4B-, 5D4C-, 5E1B-, 5E2B-, 5H-, 5H1B-, 5H2B-, 5H3B-, 5H5B-, 5L4B-, 5L4C-, 5P1B-, 5P2B-, 5P3B-, 5P5B-, 7O2C-, 7O2B-, 7F2C-, 7F2B-, 7D2C-, 7D2B-, 6I5B-, 6I3B-, 6F5B-, 6F3B-, 6BAB-, 6AAB-, 65I-, 65F-, 5W8C-, 5W8B-, 5W5B-, 5W4D-, 5W4C-, 5W4B-, 5W3B-
Region/Country: Russia (TR CU)
Approval Agency: EAC
Approval Number: EAEC N RU D-CH.AD07.B.03271/20MiscellaneousRussian -
t-mass T, Prowirl R, Prowirl O, Prowirl F, T-MASS I, T-MASS F, t-mass B, t-mass A, t-mass, Prowirl D, PROSONIC FLOW P, Prosonic Flow G, PROSONIC FLOW E, Prosonic Flow 93, Prosonic Flow B, Prosonic Flow 92, Prosonic Flow 91, PICOMAG, Magphant, Dosimass, Promass 40, Promag D
Product Code: 92F-, ODMA-, 7R2B-, 7F2B-, 93P-, 93W-, 7O2B-, 7D2B-, 7O2C-, 7F2C-, 7R2C-, 65I-, 93C-, 7D2C-, 65F-, 93TA1-, 9B2B-, 9E1B-, 9EHB-, 9G3B-, 9G5B-, 9P5B-, DMA-, DTI200-, DTT31-, DTT35-, DTT35L-, DTT31L-, 91W-, 8E-, 6TAB-, 6I5B-, 6I3B-, 6F5B-, 6F3B-, 6BAB-, 6AAB-, 5D4C-, 40E-
Region/Country: Russia (TR CU)
Approval Agency: EAC
Approval Number: EACE N RU-D.CH.AD07.B.02246/20MiscellaneousRussian -
Prosonic Flow 91, Prosonic Flow 92, Prosonic Flow 93, Prosonic Flow G, Prowirl D, Prowirl F, Prowirl O, Prowirl R
Product Code: 9G5B-, 9G3B-, 93W-, 92F-, 91W-, 7R2C-, 7R2B-, 7O2C-, 7O2B-, 7F2C-, 7F2B-, 7D2C-, 7D2B-
Region/Country: Russia (TR CU)
Approval Agency: EAC
Approval Number: EAEC RU C-CH.AD07.B.01756/20MiscellaneousRussian -
Prosonic Flow G
Product Code: 9G3B-, 9G5B-
Region/Country: Canada
Approval Agency: CSAExplosion ProtectionEnglish -
Prosonic Flow G
Product Code: 9G3B-, 9G5B-
Region/Country: Canada, USA
Approval Agency: CSA
Category: I/1/A,B,C,D,E,F,GExplosion ProtectionEnglish -
Prosonic Flow G
Product Code: 9G5B-
Region/Country: Japan
Approval Agency: CMLExplosion ProtectionJapanese -
Prosonic Flow G
Product Code: 9G3B-, 9G5B-
Region/Country: Canada, USA
Approval Agency: CSA
Category: I/2/A,B,C,D,E,F,GExplosion ProtectionEnglish -
Prosonic Flow G
Product Code: 9G3B-, 9G5B-
Region/Country: Brazil
Approval Agency: TÜV
Category: zone 2
Protection: Ex ecExplosion ProtectionPortuguese -
Prosonic Flow G
Product Code: 9G3B-, 9G5B-
Region/Country: China
Approval Agency: NEPSI
Category: zone 21, zone 0,1Explosion ProtectionChinese -
Prosonic Flow G, PROSONIC FLOW P
Product Code: 9G3B-, 9G5B-, 9P5B-
Region/Country: Europe (ATEX)
Approval Agency: SIRA
Protection: Ex tb, Ex ia tb, Ex db eb ia, Ex dbExplosion ProtectionEnglish -
Prosonic Flow G, PROSONIC FLOW P
Product Code: 9G3B-, 9G5B-, 9P5B-
Region/Country: International (IECEx)
Approval Agency: CSA
Protection: Ex ecExplosion ProtectionEnglish -
Prosonic Flow G, PROSONIC FLOW P
Product Code: 9G3B-, 9G5B-, 9P5B-
Region/Country: International (IECEx)
Approval Agency: CSA
Protection: [Ex ia], Ex ia, Ex tb, Ex ec, Ex db eb, Ex dbExplosion ProtectionEnglish -
Prosonic Flow G
Product Code: 9G3B-, 9G5B-
Region/Country: Canada, USA
Approval Agency: CSA
Category: I/2/A,B,C,D,E,F,GExplosion ProtectionEnglish -
Prosonic Flow G
Product Code: 9G3B-, 9G5B-
Region/Country: Brazil
Approval Agency: TÜV
Category: zone 1, zone 21
Protection: Ex ec, Ex db eb, Ex db, Ex ia, Ex tbExplosion ProtectionPortuguese -
Prosonic Flow G
Product Code: 9G3B-, 9G5B-
Region/Country: Canada, USA
Approval Agency: CSA
Category: I/1/A,B,C,D,E,F,GExplosion ProtectionEnglish -
Prosonic Flow G
Product Code: 9G3B-, 9G5B-
Region/Country: China
Approval Agency: NEPSI
Category: zone 2Explosion ProtectionChinese -
Prosonic Flow G
Product Code: 9G3B-, 9G5B-
Region/Country: Russia
Protection: Ex d [ia] IIC T6...T1 Gb, Ex d e [ia] IIC T6...T1 Gb, Ex ia IIC T6...T1 Gb, Ex nA IIC T5 Gc, Ex nA IIC IIC Gc, Ex tb IIIC Txxx°C Db, Ex d [ia Ga] IIC T6...T1 Gb, Ex d e [ia Ga] IIC T6...T1 Gb, Ex tb [ia Da] IIIC Txxx°C DbExplosion ProtectionRussian -
Prosonic Flow G
Product Code: 9G3B-, 9G5B-
Region/Country: Canada
Approval Agency: CSAExplosion ProtectionEnglish -
T-MASS I, Promass O, Promass F, Promass E, Promass Q, Promass I, Promass P, Promass S, Promass H, Promass X, Cubemass C, T-MASS F, PROSONIC FLOW P, Prosonic Flow G
Product Code: 8Q5B-, 8O5B-, 8F5B-, 8E5B-, 8S5B-, 8I5B-, 8P5B-, 8H5B-, 8O3B-, 8Q3B-, 8F3B-, 8E3B-, 8I3B-, 8S3B-, 8P3B-, 8H3B-, 8X3B-, 8C5B-, 8C3B-, 8X5B-, O8E5B-, O8F3B-, O8F5B-, O8Q3B-, O8Q5B-, 9G3B-, 9G5B-, 9P5B-, O8E3B-, O8O3B-, O8O5B-, O8X3B-, O8X5B-, 6I5B-, 6I3B-, 6F3B-, 6F5B-
Region/Country:
Approval Agency:Explosion ProtectionEnglish -
Prosonic Flow G
Product Code: 9G3B-, 9G5B-
Region/Country: International
Approval Agency: FieldComm Group
Software Version: 01.00.01Fieldbus ConformanceEnglish
Accessories / Spare parts
-
-
Nr 31 Order code 71323009
Kit pow.supply,100-230VAC/24VDC, Non-haz
Usage: Promag/Promass/Prosonic Flow/ t-mass 300/500 digital, Non-haz, Zone 2, transmitter housing, electronic compartment.
-
-
-
Nr 47 Order code 71323013
Kit main elec.extender,500 dig., Non-haz
Usage: Promag/Promass/Prosonic Flow/ t-mass 500 digital, transmitter housing, electronic compartment.
-
Nr 47 Order code 71323014
Kit main elec. extender, 500 dig.,Ex
Usage: Promag/Prosonic Flow 500 digital, transmitter housing, electronic compartment.
-
-
-
Nr 36 Order code 71434751
Kit ISEM extender, 500 digital, Ex
Usage: Prosonic Flow 500 digital, Sensor connection housing.
-
-
-
Nr 33 Order code XPD0048-
ISEM electr.mod.,Prosonic Flow G 300/500
Usage: Prosonic Flow G 300/500. Valid for all approvals.
-
-
-
Nr 39 Order code 71185788
Kit T-DAT, 100/300/400/500/500 digital
Usage: Promag/Promass 100/300/500, 500 digital, Prosonic Flow E 100, Prosonic Flow/t-mass 300, 500 digital, Promag 400(C). (C) = generation index C.
-
-
-
Nr 34 Order code XPD0037-
-
-
-
Nr 46 Order code 71459753
Kit ISEM ribbon cable, 500 digital
Usage: Prosonic Flow 500 digital, sensor connection housing.
-
-
-
Nr 35 Order code XPD0038-
-
-
-
Nr 50 Order code XPD0031-
-
-
-
Nr 45 Order code 71323077
Kit terminal option A, 500 dig., Non-haz
Usage: transmitter housing Alu/polycarbonate, connection compartment. Option A = HART, PROFIBUS PA, FOUNDATION Fieldbus. Consists of: 1x connection terminal 2-Pol., 1x connection terminal 3-Pol., 1x connection terminal 4-Pol., 1x connection terminal 6-Pol.
-
Nr 45 Order code 71327820
Kit terminal option C, 500 dig., Non-haz
Usage: transmitter housing Alu/polycarbonate, connection compartment. Option C = PROFIBUS DP, Modbus RS485. Consists of: 1x connection terminal 2-Pol., 1x connection terminal 3-Pol., 1x connection terminal 4-Pol., 1x connection terminal 6-Pol.
-
-
-
Nr 20 Order code 71384170
Kit cover, alu,Promag 400(C),500 digital
Usage: Promag 400(C) = generation index C, Promag/Promass/Prosonic Flow/t-mass 500 digital, transmitter housing Alu. Consists of: cover Alu complete included O-Ring 196,40x3,53 HNBR, default and -50oC/-58oF, wire with screw lock 1,5x150.
-
Nr 20 Order code 71408508
Kit cover, polycarb., 500 digital
Usage: Promag/Promass/Prosonic Flow/t-mass 500 digital, transmitter housing polycarbonate. Consists of: Cover polycarbonate complete, O-Ring 196,44x3,53 VMQ, default and -50oC/-58oF, wire with screw lock 1,5x150.
-
-
-
Nr 70 Order code 71278078
Kit cover gasket, alu,400(C),500 digital
Usage: Promag 400(C) = generation index C, Promag/Promass/Prosonic Flow/t-mass 500 digital, transmitter housing Alu. Consists of: 10x O-Ring 196,40x3,53 HNBR, default and -50oC/-58oF.
-
Nr 70 Order code 71278077
Kit 10 cover gasket, polycarbonate
Usage: Promag 400(C) = generation index C, Promag/Promass/Prosonic Flow/t-mass 500 digital, transmitter housing polycarbonate. Consists of: 10x O-Ring 196,44x3,53 VMQ.
-
-
-
Nr 24 Order code 71228796
Kit cover, remote, Alu
Usage: Promag 400(C) = generation index C, Promag 500, Promag/Promass/Prosonic Flow/t-mass 500 digital, sensor connection housing. Consists of: cover Alu, O-Ring 113,90x3,53 HNBR.
-
Nr 24 Order code 71323050
Kit cover, remote, Alu, -50oC
Usage: Promass/Prosonic Flow/t-mass 500digital, sensor connection housing. Consists of: cover Alu, O-Ring 113,90x3,53 FVMQ, -50oC/-58oF.
-
-
-
Nr 73 Order code 71323051
Kit housing gaskets, remote, Alu
Usage: Promass/Prosonic Flow/t-mass 500digital, sensor connection housing. Consists of: O-Ring 113,90x3,53 HNBR for cover, gasket EPDM for housing/sensor.
-
Nr 73 Order code 71323052
Kit housing gaskets, remote, Alu, -50oC
Usage: Promass/Prosonic Flow/t-mass 500digital, sensor connection housing. Consists of: O-Ring 113,90x3,53 FVMQ for cover, -50oC/-58oF, gasket FVMQ for housing/sensor, -50oC/-58oF.
-
-
-
Nr 24 Order code 71323063
Kit cover, remote, cast, Ex
Usage: Promag/Promass 500, Promag/Promass/Prosonic Flow/t-mass 500 digital, sensor connection housing. Consists of: cover cast, O-Ring 120,2x3,53 HNBR.
-
Nr 24 Order code 71323064
Kit cover, remote, cast, -50oC, Ex
Usage: Promass 500, Promass/Prosonic Flow/t-mass 500digital, sensor connection housing. Consists of: cover cast, O-Ring 120,2x3,53 FVMQ, -50oC/-58oF.
-
-
-
Nr 73 Order code 71323065
Kit housing gaskets, remote, cast, Ex
Usage: Promass 500, Promass/Prosonic Flow/t-mass 500digital, sensor connection housing. Consists of: O-Ring 120,2x3,53 HNBR for cover, O-Ring 88,50x3,53HNBR for housing/sensor
-
Nr 73 Order code 71323066
Kit housing gaskets,remote,cast,-50oC,Ex
Usage: Promass 500, Promass/Prosonic Flow/t-mass 500digital, sensor connection housing. Consists of: O-Ring 120,2x3,53 FVMQ for cover, -50oC/-58oF, O-Ring 88,50x3,53 FVMQ for hous./sensor, -50oC/-58oF.
-
-
-
Nr 13 Order code 71276494
Kit securing clamp, screw
Usage: Promass 100, Promag 100, Prosonic Flow E 100/E Heat, CNGmass, LPGmass, LNGmass. Sensor housing: Promag 400(C), (C) = generation index C, Promag/Promass 500, Promag/Promass/Prosonic Flow/t-mass 500 digital. Consists of: cover clamp, screw M4x16.
-
-
-
Nr 82 Order code 71228792
Kit display protec., 400(C)/500 digital
Usage: Promag 400(C) = generation index C, Promag/Promass/Prosonic Flow/t-mass 500 digital, transmitter housing Alu. Consists of: display protection 1.4301, installation material.
-
-
-
Nr 87 Order code 71343504
Kit weather protection cover,500 digital
Usage: Promag/Promass/Prosonic Flow/t-mass 500 digital, transmitter housing. Consists of: weather protection cover 4404.
-
-
-
Order code 71346427
Pipe Mounting kit Transmitter 500digital
-
Order code 71351317
Kit wireless antenna extended range
Consists of: Connection cable in the transmitter, Ex cable entry for antenna, 1.5m cable, antenna, angle with union nut.
-
Order code 9X5BXX-
-