Training
TMT142R
RTD thermometer, fieldtransmitter display
Safe monitoring of process temperatures in challenging applications e. g. in the Oil & Gas industry
The robust thermometer is designed for use in demanding and safety relevant applications e.g. in the Chemical, Oil & Gas and Energy industry. The thermometer fulfills the corresponding safety requirements due to various certificates and tests. The use of a transmitter leads to higher accuracy and reliability in comparison to directly wired sensors.
-
Standard products
- Reliable, robust and low-maintenance
Technical excellence
Simplicity
-
Specialized products
- Designed for demanding applications
Technical excellence
Simplicity
Variable
FLEX selections | Technical excellence | Simplicity |
---|---|---|
Fundamental selection Meet your basic measurement needs |
Technical excellence
|
Simplicity
|
Lean selection Handle your core processes easily |
Technical excellence
|
Simplicity
|
Extended selection Optimize your processes with innovative technologies |
Technical excellence
|
Simplicity
|
Xpert selection Master your most challenging applications |
Technical excellence
|
Simplicity
Variable |
-
Specs at a glance
-
Accuracy
class A acc. to IEC 60751
class AA acc. to IEC 60751 -
Response time
depending on configuration
t50 = 3 s
t90 = 7 s -
Max. process pressure (static)
Depending on thermowell
-
Operating temperature range
PT 100:
-200 °C ...600 °C
(-328 °F ...1.112 °F) -
Max. immersion length on request
up to 30.000,00 mm (1.181,10'')
-
Quick selection
Individual configuration
-
Benefits
HART® protocol for operating the device on site using handheld terminal (DXR375) or remotely via the PC
Illuminated display, rotatable
Single Pt100 with 3 or 4 wires connection
Undervoltage detection responds immediately, output of falsified measured...
-
Field of application
The temperature assembly TMT142R is a compact resistance thermometer specifically designed to fulfill the requirements of different process industries such as the chemical, petrochemical and energy but even suitable to other general purpose applications...
Documents / Manuals / Software
-
Technical information TMT142R
Technical information compact thermometer TMT142R, Omnigrad S
Technical Information (TI) -
iTEMP TMT142B
Temperature field Transmitter with HART® Communication and Bluetooth®
interfaceShort Instruction (KA)07/20English -
TMT142R, TMT142C
RTD / Thermocouple assembly with field transmitters
ATEX Installation types
II2G Ex d IIC T6…T4 Gb
II1G Ex ia IIC T6…T1 Ga
Safety instructionsEx Safety Instructions (XA) -
Omnigrad S RTD and TC Thermometer with display
TMT142R, TMT142C
ATEX:
Ex ia IIC T6...T1 Ga
Ex ia IIIC T85 °C...T450 °C Da/Db
Safety Instructions
Temperature field transmitter, ATEX Safety instructions
Ex Safety Instructions (XA) -
Omnigrad S RTD and TC Thermometer with display
TMT142R, TMT142C
ATEX:
Ex d IIC T6...T1 Ga/Gb
Ex tb IIIC T85 °C...T450 °C Da/Db
Safety Instructions
Temperature field transmitter, ATEX Safety instructions
Ex Safety Instructions (XA) -
Omnigrad S RTD and TC Thermometer with display
TMT162R/C, TMT142R/C
ATEX II 3G
Safety Instructions
Temperature field transmitter, ATEX Safety instructions
Ex Safety Instructions (XA) -
TMT142R, TMT142C
RTD and TC Thermometer with display
0Ех ia IIC T6…T1 Ga Х
Ga/Gb Ex ia IIC T6...T1 X
Ex ia IIIC T85 °C...T450 °C Da/Db XEx Safety Instructions (XA) -
TMT142R, TMT142C
RTD and TC Thermometer with display
1Ex d IIC T6...T1 Gb X
Ex tb IIIC 85 °C....450 °C Db X
Ga/Gb Ex d IIC T6...T1 X
Ex ta/tb IIIC 85 °C...450 °C Da/Db XEx Safety Instructions (XA) -
Omnigrad S RTD and TC Thermometer with display
TMT142R, TMT142C
ATEX Ex ia IIC T6…T1 Ga
Safety Instructions
Temperature field transmitter, ATEX Safety instructions
Ex Safety Instructions (XA) -
Mesure de température
Capteurs et transmetteurs pour les industries de process
Fields of Activities (FA)12/19fr -
温度测量
过程工业用温度传感器和温度变送器
Fields of Activities (FA)12/14Chinese -
Pomiar temperatury
Czujniki i przetworniki pomiarowe
do kontroli przemysłowych procesów technologicznychFields of Activities (FA)10/14Polish -
Измерение температуры
Датчики температуры и преобразователи для любых
отраслей промышленности.Fields of Activities (FA)06/13Russian -
Catálogo medición temperatura
Termómetros y transmisores para la industria de proceso
Fields of Activities (FA)04/18Spanish -
Misura della temperatura
Termometri e trasmettitori
per l'industria di processoFields of Activities (FA)04/18Italian -
Sıcaklık Ölçümü
Proses endüstrisi için termometreler ve transmiterler
Fields of Activities (FA)03/13Turkish -
Field of activities FA Temperature measurement
Thermometers and transmitters for the process industry
Fields of Activities (FA)03/13English -
Temperature measurement
Thermometers and transmitters for the process industry
Fields of Activities (FA)02/20English -
Temperaturmesstechnik
Thermometer und Transmitter für die Prozessindustrie
Fields of Activities (FA)02/20German -
Измерение температуры
Ключевые особенности термометров Endress+Hauser для нефтегазовой отрасли
Competence Brochure (CP)08/11Russian -
Инженерные решения по термометрии
Специальные решения по термометрии для химической и
нефтеперерабатывающей промышленностиCompetence Brochure (CP)04/10Russian -
EDD Single, PDM_HART_TE_iTEMP_TMT142_0x00CB_0x02_0x04, 03.10.2019 (Temperature, iTEMP, 0x00CB)
HART,
PDM Version: 8.2.1, 9.1.0.4Electronic Data Description (EDD)1.00.00Language neutral -
DTM Single, ITEMP_TMT142_V1_03_xx, 26.10.2020 (Temperature, iTEMP, 0x00CB)
HART,
DeviceCare Version: 1.07.00
Field Xpert - SMT70 Version: 1.05.00
FieldCare Version: 2.15.00Device Type Manager (DTM)1.4.188.39Language neutral -
Faceplate Library, PRM_HART_Package_Temp_1_08_00, 03.12.2015 (Temperature)
HART,
Plant Resource Manager Version: R3.05, R3.11Faceplate1.08.00Language neutral -
Process RTD Heavy duty
Product Code: TMT142R-
Declaration Number: HE_00505_01.17
Manufacturer Specification: RoHSManufacturer DeclarationEnglish -
RTD-thermometer, Process TC Heavy duty, Process TC General purpose, Process TC Explosion proof, Process TC direct in contact, Process TC Direct contact, Process RTD Hygienic, Process RTD Heavy duty, Process RTD General purpose, Process RTD Explosion proof, Process RTD direct in contact, Process RTD Direct contact, Plugs RTD direct contact, Magphant, Low cost RTD General purpose, Industrial Modular Thermometer
Product Code: TR15-, TR13-, TR12-, TR11-, TR10-, TMT470L-, TMT162R-, TMT162C-, TMT142R-, TMT142C-, TMR35L-, TMR35-, TMR31L-, TMR31-, TM411-, TM401-, TH56-, TH55-, TH54-, TH53-, TH52-, TH51-, TR24-, TTR35-, TTR31-, TST90-, TST602-, TST487-, TST434-, TST41N-, TST414-, TST410-, TST40N-, TST310-, TST187-, TSM487-, TSM187-, TSC310-, TR88-, TR66-, TR65-, TR63-, TR62-, TR61-, TR25-, TH27-, T55-, T54-, T53-, T15-, T14-, T13-, OTR96-, OTR95-, OTR94-, OTR93-, OTR92-, OTR91-, OTR90-, OTR35-, OTR31-, MLTTS01-, MLTTS00-, GPTL-, DTT35L-, DTT35-, DTT31L-, DTT31-, TAF11-, TH18-, TH17-, TH15-, TH14-, TH13-, TH12-, TH11-, TEC420-, TC88-, TC66-, TC65-, TC63-, TC62-, TC61-, TC15-, TC13-, TC12-, TC10-, TAF16-, TAF12T-, TAF12S-, TAF12D-
Declaration Number: EC_00568_01.17EU DeclarationGerman , English , fr -
Process RTD Heavy duty, Process TC Heavy duty
Product Code: TMT142C-, TMT142R-, TMT162C-, TMT162R-
Declaration Number: EC_00185_01.16EU DeclarationGerman , English , fr -
Process RTD Heavy duty, Process TC Heavy duty
Product Code: TMT142C-, TMT142R-
Declaration Number: EC_00173_01.16EU DeclarationGerman , English , fr -
Process RTD Heavy duty, Process TC Heavy duty
Product Code: TMT142C-, TMT142R-, TMT162C-, TMT162R-
Declaration Number: EC_00330_01.16EU DeclarationGerman , English , fr -
Process RTD Heavy duty, RTD-thermometer
Product Code: TMR31-, TMR35-, TMT142R-, TMT162R-, TTR31-, TTR35-
Region/Country: Russia (TR CU)
Approval Agency: EAC
Approval Number: TC BY_112 11.01. TP020 003 143MiscellaneousRussian -
Process RTD Heavy duty, Process TC Heavy duty
Product Code: TMT142C-, TMT142R-, TMT162C-, TMT162R-
Region/Country: China
Approval Agency: ACMA
Approval Number: MD-17030A/09/ENMiscellaneousEnglish -
DIN Rail Transmitter, Field transmitter, head transmitters, Process RTD Heavy duty, Process TC Heavy duty
Product Code: TMT82-, TMT80-, TMT188-, TMT187-, TMT182-, TMT181-, TMT180-, TMT162R-, TMT162C-, TMT142R-, TMT142C-, TMT128-, TMT127-, TMT122-, TMT121-, TMT112-, TMT111-
Region/Country: Russia (TR CU)
Approval Agency: EAC
Approval Number: TC BY_112 11.01. TP020 003 126MiscellaneousRussian -
Process RTD Heavy duty, Process TC Heavy duty
Product Code: TMT162R-, TMT162C-, TMT142R-, TMT142C-
Region/Country: South Korea
Approval Agency: KOSHA
Protection: Ex ia IIC T6...T4Explosion Protection -
Process RTD Heavy duty, Process TC Heavy duty
Product Code: TMT142C-, TMT142R-, TMT162C-, TMT162R-
Region/Country: Europe (ATEX)
Approval Agency: KEMA
Category: II 1 G, II 1/2 G, II 1/2 D, II 2 G, II 2 D
Protection: Ex d IIC T6...T1 Gb, Ex ia IIC T6...T1 Ga, Ex ia IIC T6...T1 Ga/Gb, Ex ia IIC T450°C Da/Db, Ex tb IIC T450°C Db, Ex ta/tb IIC T450°C Da/Db, Ex d IIC T6...T1 Ga/GbExplosion ProtectionGerman , English -
Process RTD Heavy duty, Process TC Heavy duty
Product Code: TMT142C-, TMT142R-, TMT162C-, TMT162R-
Protection: Ex d IIC T6...T1 Ga/Gb, Ex d IIC T6...T1 Gb, Ex ia IIC T6...T1 Ga, Ex ia IIC T6...T1 Ga/Gb, Ex ia IIIC T6...T1 Da/Db, Ex tb IIIC T6...T1 Db, Ex ta/tb IIIC T6...T1 Da/DbExplosion ProtectionRussian -
Process RTD Heavy duty, Process TC Heavy duty
Product Code: TMT162R-, TMT162C-, TMT142R-, TMT142C-
Region/Country: South Korea
Approval Agency: KOSHA
Protection: Ex d IIC T6...T4Explosion Protection -
Process RTD Heavy duty, Process TC Heavy duty
Product Code: TMT142C-, TMT162R-, TMT162C-, TMT142R-
Region/Country: Russia
Approval Agency: Rosstandart
Approval Number: IT.C.32.004.A_62156/1MetrologyRussian
Accessories / Spare parts
-
-
Nr 8 Order code 51004387
Adapter NPT1/2/M20x1.5 cable entry
-
Nr 8 Order code 51004915
Adapter M20x1.5 exter./M24x1.5 intern.VA
-
Nr 8 Order code 51004949
Cable entry M20x1.5
-
Nr 8 Order code 51006845
Cable gland NPT1/2, D4.5-8.5 IP68
-
Nr 8 Order code 51007995
Mounting bracket SS316L, tube 1,5-3"
-
-
-
Nr 2 Order code 71310423
-
-
-
Nr 5 Order code TMT142X-HA
Housing cover blind, 316L Ex d, FM XP, CSA XP + O-ring
-
Nr 5 Order code TMT142X-HB
Housing cover blind, 316L + O-ring
-
Nr 5 Order code TMT142X-HC
Housing cover cpl. for display,316L Ex d FM XP, CSA XP, with O-ring
-
Nr 5 Order code TMT142X-HD
Housing cover cpl. for display, 316L + O-Ring
-
Nr 5 Order code TMT142X-HH
Housing cover blind, Alu Ex d FM XP without O-ring CSA XP only as cover of terminal part
-
Nr 5 Order code TMT142X-HI
Housing cover blind, Alu + O-ring
-
Nr 5 Order code TMT142X-HK
Housing cover cpl. for display, Alu Ex d + O-ring
-
Nr 5 Order code TMT142X-HL
Housing cover cpl. for display, Alu + O-ring
-
-
-
Nr 7 Order code 51004948
-
-
-
Nr 2+3 Order code TMT142X-DA
Display HART5 + fitting kit + twist protection
-
Nr 2+3 Order code TMT142X-DC
Display fitting kit + twist protection
-
-
-
Nr 9 Order code 51004489
Blanks (blind) M20x1.5 EEx-d/XP
-
Nr 9 Order code 51004490
Blanks (blind) NPT1/2, 3.1655.53
-
Nr 9 Order code 51004916
Blanks (blind) G1/2" Ex-d/XP
-
Nr 9 Order code 51006888
Blanks (blind) 1/2NPT V4A
-
-
-
Order code TET300-
RTD Insert TET300
Replaceable Insert (MgO). Connection to EEx d head with NPT1/2. Diameter: D=6mm.
-
Order code FXA195-
Commubox FXA195
Modem to connect HART field devices to a computer via USB. Commissioning of field devices with software tool. :: To connect to a intrinsically safe signal circuit. :: SIL2, IEC61508.
-
-
-
Nr 4 Order code TMT142E-
Electronic TMT142E
-
-
-
Nr 1 Order code TMT142G-
Housing TMT142G
-