Raman spectroscopy - advanced optical analysis technology
Boost plant safety, ensure product quality, and optimize operations. Raman spectroscopy measures the composition and molecular structure of your samples from lab-to-process in real time.
Raman Rxn-10 probe
Metal: C276 alloy as standard (316L stainless steel or Grade 2 titanium upon request)
Window: high-purity sapphire, proprietary compression fit non-brazed design
The fixed focus design of the Raman immersion optic provides long-term measurement stability along with superior signal performance which is essential for transferable, high-performance Raman measurements. Compatible with the Rxn-10 probe, the immersion optic uses no movable parts so it is always in focus. The Raman immersion optic is well-suited for use in reaction vessels, laboratory reactors, or process streams, and its wettable components resist corrosion in harsh environments.
Pharmaceutical: drug substance unit operations, reaction analysis, crystallization, end-point detection, solvent swaps
Chemical: material identification, reaction analysis, polymerization, cross-linking, blending
Food & Beverage: blending, purification, natural and synthetic components
Development laboratory: versatile in situ analysis, feasibility studies, model development (or similar)
Ideal for quick measurements of liquids, slurries, and semi-solids in a laboratory setting
Superior signal performance
Available in 1/4” and 1/2” diameters
No user-adjustable parts
Wettable components resist corrosion in harsh environments (including acidic solutions)
High-end products
Technical excellence
Simplicity
Standard products
Technical excellence
Simplicity
Specialized products
Technical excellence
Simplicity
Variable
| FLEX selections | Technical excellence | Simplicity |
|---|---|---|
Fundamental selection Meet your basic measurement needs |
Technical excellence
|
Simplicity
|
Lean selection Handle your core processes easily |
Technical excellence
|
Simplicity
|
Extended selection Optimize your processes with innovative technologies |
Technical excellence
|
Simplicity
|
Xpert selection Master your most challenging applications |
Technical excellence
|
Simplicity
Variable |
Construction du système et spécifications de la sonde Raman Rxn-10
| EN | |||
|
08/09/2025
|
|
|
|
|
Language: |
French |
|
Version: |
08/09/2025 |
|
File size: |
1018.3 KB |
|
File name: |
TI01629CFR_0525.pdf |
Commissioning, operation, and maintenance details
for Rxn-10 probe optics: Raman immersion optics (KIO1),
non-contact optics (KNCO1), bIO-Optics (KLBIO1), and
Raman optic system for single use (KRSU1)
|
Language: |
English |
|
Version: |
03/08/2022 |
|
File size: |
1.2 MB |
|
File name: |
BA02171CEN_0222.pdf |
Raman Rxn‑10 プローブの設定、操作、メンテナンスの詳細
| EN | |||
|
08/09/2025
|
|
|
|
|
Language: |
Japanese |
|
Version: |
08/09/2025 |
|
File size: |
2.8 MB |
|
File name: |
BA02160CJA_0525.pdf |
A list of published technical articles related to Biopharma 4.0
topics with recommendations from Life Science industry experts
at Endress+Hauser.
|
Language: |
English |
|
Version: |
26/06/2025 |
|
File size: |
363.4 KB |
|
File name: |
PU01611CEN_0125.pdf |
Ein Leitfaden zu unseren Anwendungshinweisen zur
Raman-Spektroskopie für die Life-Science-Industrie
(Raman Rxn2-Analysator, Raman Rxn4-Analysator,
Rxn-10-Sonde, Rxn-20-Sonde, Rxn-45-Sonde,
Rxn-46-Sonde und Zubehör für Sondenoptiken
(blO-Optic, Raman- Single Use-Optiksystem
/ SUB, Immersionsoptik, berührungslose Optik)
|
Language: |
German |
|
Version: |
24/09/2025 |
|
File size: |
1.4 MB |
|
File name: |
PU01447CDE_0222_Raman-Anwendungsleitfaden_LSI_web.pdf |
A guide to our Raman spectroscopy application notes for the
Life Science industry (featuring the Raman Rxn2 analyzer,
Raman Rxn4 analyzer, Rxn-10 probe, Rxn-20 probe, Rxn-45 probe,
Rxn-46 probe, and probe accessory optics (bIO-Optic, Raman single
use optic system / SUB, immersion optic, non-contact optic).
|
Language: |
English |
|
Version: |
19/04/2022 |
|
File size: |
1.1 MB |
|
File name: |
PU01447CEN_0222.pdf |
A list of definitions and sources for frequently used terms and
abbreviations in the biopharmaceutical industry related to
Biopharma 4.0.
|
Language: |
English |
|
Version: |
17/06/2025 |
|
File size: |
445 KB |
|
File name: |
PU01610CEN_0125.pdf |
本ガイドでは、食品・飲料業界におけるラマン分光法のアプリケー
ションノートについてご紹介しています。Raman Rxn2アナライザ、
Raman Rxn4アナライザ、Rxn-10プローブ、Rxn-20プローブ、Rxn-45
プローブ、ならびに浸漬式オプティックおよび非接触式オプティッ
クを用いた研究事例を取り上げています。
|
Language: |
Japanese |
|
Version: |
30/10/2025 |
|
File size: |
1.4 MB |
|
File name: |
CP01489CJA_0122_Raman Use in Food and Beverage.pdf |
A guide to Raman spectroscopy application notes for the
food & beverage industry (featuring studies using the
Raman Rxn2 analyzer, Raman Rxn4 analyzer, Rxn-10 probe,
Rxn-20 probe, Rxn-45 probe, and the immersion optic
and non-contact optic).
|
Language: |
English |
|
Version: |
17/02/2022 |
|
File size: |
859 KB |
|
File name: |
CP01489CEN_0122.pdf |
Eine Übersichtsbroschüre über unser Raman-Spektroskopie-Sondenportfolio
einschließlich der Sonden Rxn-10, Rxn-20, Rxn-30,
Rxn-40, Rxn-41, Rxn-45, Rxn-46 und Sonden-Zubehöroptiken
(bIO-Optic, Raman-Singel-Use optiken/SUB,
Immersionsoptik, berührungslose Optik),
die auf der Kaiser Raman-Technologie basiert.
|
Language: |
German |
|
Version: |
24/09/2025 |
|
File size: |
1.1 MB |
|
File name: |
IN01225CDE_0121_Raman_Sonden_web.pdf |