Oil leak detector
Transmitter NRR262
Oil leak detection system provides excellent leak detection of petrochemicals, vegetable oils, etc.
Indoor installed transmitter to output relay contact to receive the detection signal from the NAR300 float sensor.
-
Benefits
Indoor installed transmitter to output relay contact to receive the detection signal from the NAR300 float sensor.
Exi certified transmitter
Delay trimmer prevents false alarm and relieves operators from disturbance
No moving parts, long-life
-
Field of application
Ambient temperature: 0 to +50°C (32 to +122°F)
Documents / Manuals / Software
-
Oil leak detector NAR300 high temperature
Technical Information
Oil leak detector
Technical Information (TI) -
Oil leak detector NAR300
Technical Information
Oil leak detector
Technical Information (TI) -
NAR300 system high temperature
Operating Instructions
Tank gauging
Operating Instruction (BA) -
NAR300 system - Operating Instruction
Tank Gauging
Operating Instruction (BA) -
NAR300 system
Operating Instructions
Tank gauging
Operating Instruction (BA) -
NAR300 system - Operating Instruction
Tank Gauging
Operating Instruction (BA) -
Oil Leak Detector NAR300 System - Safety Instructions
Oil Leak Detector NAR300 System
TIIS Ex ia IIB T4Ex Safety Instructions (XA) -
Converter NRR262
for oil leak detector NAR300
[Ex ia Gb]
Safety Instructions
Converter NRR262 for oil leak detector NAR300 for JPN Ex.
If it export to outside of Japan, attach this XA.Ex Safety Instructions (XA) -
Safety Instructions
NRR262
FM
Ex Safety Instructions (XA) -
Safety Instructions
NRR262
ATEX/IECEx
Ex Safety Instructions (XA) -
Safety Instruction for NRr262 (ZB; 9001/01-280-85); ATEX/IECEx
Applicable from orders after 1st Oct. 2018.
Safety Instruction for NRr262 (ZB; 9001/01-280-85); ATEX/IECEx
Applicable from orders after 1st Oct. 2018.Ex Safety Instructions (XA) -
Safety Instruction for NRR262 (ZB; 9001/01-280-85); FM
Applicable from orders after 1st Oct. 2018.
Safety Instruction for NRR262 (ZB; 9001/01-280-85); FM
Applicable from orders after 1st Oct. 2018.Ex Safety Instructions (XA) -
Converter NRR261 for Oil Leak Detector - Safety Instructions
Converter NRR261 for Oil Leak Detector
TIIS Ex d[ia] IIB T4Ex Safety Instructions (XA) -
Converter NRR262 for Oil Leak Detector - Safety Instructions
Converter NRR262 for Oil Leak Detector
TIIS Ex ia IIB T4Ex Safety Instructions (XA) -
Tank Gauging
Система коммерческого и оперативного учета продуктов
в резервуарных парках.Competence Brochure (CP)07/15Russian -
NRR262_picture
Oil Leak Detector NAR300 System
NRR262Picture10/07English , Japanese -
Sakura
Product Code: NAR300-, NRR261-, NRR262-
Declaration Number: EC_00541_01.17EU DeclarationGerman , English , fr -
Sakura
Product Code: NAR300-, NRR261-, NRR262-
Declaration Number: EC_00736_01.19EU DeclarationEnglish -
Sakura
Product Code: NAR300-, NRR261-, NRR262-
Region/Country: International (IECEx)
Approval Agency: IECEx
Protection: Ex d [ia] IIB T4 Ga/GbExplosion ProtectionEnglish -
Sakura
Product Code: NAR300-, NRR261-, NRR262-
Region/Country: Europe (ATEX)
Approval Agency: FM
Category: II 2 G, II 1/2 G
Protection: [Ex ia] IIB Txxx°C Gb, Ex d [ia] IIB T4 Ga/Gb, Ex ia IIB T4 Ga/GbExplosion ProtectionEnglish -
Sakura
Product Code: NAR300-, NRR261-, NRR262-
Region/Country: Japan
Approval Agency: CML
Protection: [Ex ia] IIB Txxx°C, Ex d [ia] IIB T6 Gb, Ex ia IIB T5 Ga, Ex db [ia Ga] IIB T4 GbExplosion ProtectionJapanese -
Sakura
Product Code: NAR300-, NRR261-, NRR262-
Region/Country: USA
Approval Agency: FM
Category: I/1/C,D,E,F,G/T5, I/zone 0
Protection: AIS, IS, XP/AIS, AEx [ia] IIB Txxx°C, AEx d [ia] IIB T4 Ga/Gb, AEx ia IIB T5 GaExplosion ProtectionEnglish -
Sakura, System&Gauging
Product Code: NRR262-
Approval Agency: TIIS
Protection: [Ex ia] IIBExplosion ProtectionJapanese -
Sakura
Product Code: NAR300-, NRR261-, NRR262-
Region/Country: USA
Approval Agency: FM
Category: I/1/C,D,E,F,G/T5, I/zone 0
Protection: AIS, IS, XP/AIS, AEx [ia] IIB Txxx°C, AEx d [ia] IIB T4 Ga/Gb, AEx ia IIB T5 GaExplosion ProtectionEnglish -
Sakura
Product Code: NAR300-, NRR261-, NRR262-
Region/Country: Europe (ATEX)
Approval Agency: FM
Category: II 2 G, II 1/2 G
Protection: [Ex ia] IIB Txxx°C Gb, Ex d [ia] IIB T4 Ga/Gb, Ex ia IIB T4 Ga/GbExplosion ProtectionEnglish -
Sakura
Product Code: NAR300-, NRR261-, NRR262-
Region/Country: Europe (ATEX)
Approval Agency: FM
Category: II 2 G, II 1/2 G
Protection: [Ex ia] IIB Txxx°C Gb, Ex d [ia] IIB T4 Ga/Gb, Ex ia IIB T4 Ga/GbExplosion ProtectionEnglish -
Sakura
Product Code: NAR300-, NRR261-, NRR262-
Region/Country: Europe (ATEX)
Approval Agency: FM
Category: II 2 G, II 1/2 G
Protection: [Ex ia] IIB Txxx°C Gb, Ex d [ia] IIB T4 Ga/Gb, Ex ia IIB T4 Ga/GbExplosion ProtectionEnglish -
Sakura, System&Gauging
Product Code: NRR262-
Approval Agency: TIIS
Protection: [Ex ia] IIBExplosion ProtectionJapanese -
Sakura
Product Code: NAR300-, NRR261-, NRR262-
Region/Country: International (IECEx)
Approval Agency: IECEx
Protection: Ex d [ia] IIB T4 Ga/GbExplosion ProtectionEnglish -
Sakura
Product Code: NAR300-, NRR261-, NRR262-
Region/Country: International
Approval Agency: TÜVSafety Integrity Level (SIL)English
Accessories / Spare parts
-
-
Nr 31 Order code 56004437
-
Nr 31 Order code 71086629
-
-
-
Order code 71409783
-
Order code 71409784
-
Order code 71420128
Module NRR262, AC, Stahl
Usage: NRR262. ATEX/IECEx/FM ordered from Nov. 2018. TIIS ordered from Feb. 2019.
-
Order code 71420129
Module NRR262, DC, Stahl