This product is no longer available.
Please check new generation in the section predecessor / successor or contact your local Endress+Hauser entity.

Digital different. pressure transmitter.
Application: level, hydrostatic.
Sensor: capacitive.
Measuring diaphragm:Ceramic,flush mount.
:: High resistance to abrasion
Linearity +/-0,1%, turndown 100:1.
Safety by function monitoring +
membrane detection.
Modular transmitter design.
:: High reliability
Predecessor
-
Successor
-
Standard products
- Reliable, robust and low-maintenance
Technical excellence
Simplicity
-
Specialized products
- Designed for demanding applications
Technical excellence
Simplicity
Variable
FLEX selections Technical excellence Simplicity - F
- L
- E
- X
Fundamental selection
Meet your basic measurement needs
Technical excellence Simplicity - F
- L
- E
- X
Lean selection
Handle your core processes easily
Technical excellence Simplicity - F
- L
- E
- X
Extended selection
Optimize your processes with innovative technologies
Technical excellence Simplicity - F
- L
- E
- X
Xpert selection
Master your most challenging applications
Technical excellence Simplicity Variable
-
-
Measuring principle
Differential pressure
-
Characteristic
Digital differential pressure transmitter for hydrostatic level measurement, capacitive sensor with flush mounted ceramic measuring diaphragm
Safety by function monitoring and membrane detection, modular transmitter design -
Supply voltage
4...20mA / HART:
11,5...45V DC
Ex: 11,5...30V DC
PROFIBUS PA /
FOUNDATION Fieldbus:
9...32V DC
Ex: 9...24VDC -
Reference Accuracy
0,1%
-
Long term stability
0,1% of URL/year
0,25% of URL/5 years -
Process temperature
-40°C...85°C
-
Ambient temperature
-40°C...85°C
-
Measuring cell
100mbar...3bar
-
Max. Turn down
max. 100:1
-
Max. overpressure limit
100bar
-
Process connection
1/4-18NPT
RC1/4"
Flanges (DIN, ASME, JIS) -
Communication
4 ... 20mA
HART
PROFIBUS PA
FOUNDATION Fieldbus -
Certificates / Approvals
ATEX
FM
CSA
SIL
WHG/overspill protection
EN10204-3.1 -
Successor
FMD76
-
Measuring principle
Differential pressure
-
Characteristic / Application
Digital differential pressure transmitter for hydrostatic level measurement, capacitive sensor with flush mounted ceramic measuring diaphragm
Safety by function monitoring and membrane detection, modular transmitter design -
Supply / Communication
4...20 mA / HART:
11,5...45V DC
Ex: 11,5...30V DC
PROFIBUS PA /
FOUNDATION Fieldbus:
9...32V DC
Ex: 9...24VDC -
Accuracy
0,1%
-
Long term stability
0,1% of URL/year
0,25% of URL/5 years -
Ambient temperature
-40°C...85°C
-
Process temperature
-40°C...85°C
-
Process pressure absolute / max. overpressure limit
100bar
-
Pressure measuring range
100mbar...3bar
-
Main wetted parts
Alloy C
316L
Monel
Tantal -
Process connection
1/4-18NPT
RC1/4"
Flanges (DIN, ASME, JIS) -
Max. measurement distance
30m H2O
-
Communication
4 ... 20mA
HART
PROFIBUS PA
FOUNDATION Fieldbus -
Certificates / Approvals
ATEX
FM
CSA
SIL
WHG/overspill protection
EN10204-3.1 -
Options
digital display
SS- or Aluminumhousing -
Successor
FMD76
-
Application limits
Changing density