This product is no longer available.
Please check new generation in the section predecessor / successor or contact your local Endress+Hauser entity.
Predecessor
-
Successor
-
Standard products
- Reliable, robust and low-maintenance
Technical excellence
Simplicity
-
Specialized products
- Designed for demanding applications
Technical excellence
Simplicity
Variable
FLEX selections Technical excellence Simplicity - F
- L
- E
- X
Fundamental selection
Meet your basic measurement needs
Technical excellence Simplicity - F
- L
- E
- X
Lean selection
Handle your core processes easily
Technical excellence Simplicity - F
- L
- E
- X
Extended selection
Optimize your processes with innovative technologies
Technical excellence Simplicity - F
- L
- E
- X
Xpert selection
Master your most challenging applications
Technical excellence Simplicity Variable
-
-
Measuring principle
Coriolis
-
Product headline
The flowmeter with premium accuracy, robustness and extended transmitter functionality. Highest measurement performance for liquids and gases under varying, demanding process conditions.
-
Sensor features
Highest process safety – immune to fluctuating and harsh environments. Fewer process measuring points – multivariable measurement (flow, density, temperature). Space‐saving installation – no in/outlet run needs. Mass flow: measurement error ±0,05 % (PremiumCal). pressure-rated sensor housing up to 40 bar (580 psi).
-
Transmitter features
Quality – software for filling & dosing, density & concentration, advanced diagnostics. Flexible data transfer options – numerous communication types. Automatic recovery of data for servicing. 4‐ line backlit display with touch control. Device in compact or remote version.
-
Nominal diameter range
DN 8 to 250 (⅜ to 10")
High temperature: DN 25 (1"), DN 50 (2"), DN 80 (3") -
Wetted materials
Measuring tube: 1.4539 (904L); 1.4404 (316/316L); Alloy C22, 2.4602 (UNS N06022)
Connection: 1.4404 (316/316L); Alloy C22, 2.4602 (UNS N06022) -
Measured variables
Mass flow, density, temperature, volume flow, corrected volume flow, reference density, concentration
-
Max. measurement error
Mass flow (liquid): ±0.1 % (standard), 0.05 % (option)
Volume flow (liquid): ±0.1 %
Mass flow (gas): ±0.35 %
Density (liquid): ±0.0005 g/cm³ -
Measuring range
0 to 2 200 000 kg/h (0 to 80 840 lb/min)
-
Max. process pressure
PN 100, Class 600, 63K
-
Medium temperature range
Standard: –50 to +200 °C (–58 to +392 °F)
High temperature: –50 to +350 °C (–58 to +662 °F) -
Ambient temperature range
Standard: –20 to +60 °C (–4 to +140 °F)
Option: –40 to +60 °C (–40 to +140 °F) -
Sensor housing material
1.4301/1.4307 (304L), corrosion resistant
-
Transmitter housing material
Powder‐coated die‐cast aluminium
1.4301 (304), sheet
CF3M (316L), cast -
Degree of protection
IP67, type 4X enclosure. Remote transmitter: IP67, type 4X enclosure
-
Display/Operation
4‐line backlit display with touch control (operation from outside)
Configuration via local display and operating tools possible -
Outputs
4 modular outputs:
0‐20 mA (active)/4‐20 mA (active/passive)
Pulse/frequency/switch output (passive)
Relay -
Inputs
2 modular inputs:
Status
0‐20 mA (active)/4‐20 mA (active/passive) -
Digital communication
HART, PROFIBUS PA/DP, FOUNDATION Fieldbus, Modbus RS485, EtherNet/IP
-
Power supply
DC 16 to 62 V
AC 85 to 260 V (45 to 65 Hz)
AC 20 to 55 V (45 to 65 Hz) -
Hazardous area approvals
ATEX, IECEx, FM, CSA, NEPSI
-
Other approvals and certificates
3.1 material, calibration performed on accredited calibration facilities (acc. to ISO/IEC 17025), NAMUR, SIL, marine
PED, CRN, AD 2000
3-A, FDA
NACE MR0175/MR0103, PMI; welding test acc. to EN, ASME,NORSOK -
Product safety
CE, C-tick, EAC marking
-
Functional safety
CE, C-tick
-
Metrological approvals and certificates
Calibration performed on accredited calibration facilities (acc. to ISO/IEC 17025), NAMUR
-
Marine approvals and certificates
Marine approval
-
Pressure approvals and certificates
PED, CRN, AD 2000
-
Material certificates
3.1 material
NACE MR0175/MR0103, PMI; welding test acc. to EN, ASME,NORSOK -
Hygienic approvals and certificates
3-A, FDA
-
Measuring principle
Coriolis
-
Product headline
The flowmeter with premium accuracy, robustness and extended transmitter functionality. Highest measurement performance for liquids and gases under varying, demanding process conditions.
-
Sensor features
Highest process safety – immune to fluctuating and harsh environments. Fewer process measuring points – multivariable measurement (flow, density, temperature). Space‐saving installation – no in/outlet run needs. Mass flow: measurement error ±0,05 % (PremiumCal). pressure-rated sensor housing up to 40 bar (580 psi).
-
Transmitter features
Quality – software for filling & dosing, density & concentration, advanced diagnostics. Flexible data transfer options – numerous communication types. Automatic recovery of data for servicing. 4‐ line backlit display with touch control. Device in compact or remote version.
-
Nominal diameter range
DN 8 to 250 (⅜ to 10")
High temperature: DN 25 (1"), DN 50 (2"), DN 80 (3") -
Wetted materials
Measuring tube: 1.4539 (904L); 1.4404 (316/316L); Alloy C22, 2.4602 (UNS N06022)
Connection: 1.4404 (316/316L); Alloy C22, 2.4602 (UNS N06022) -
Measured variables
Mass flow, density, temperature, volume flow, corrected volume flow, reference density, concentration
-
Max. measurement error
Mass flow (liquid): ±0.1 % (standard), 0.05 % (option)
Volume flow (liquid): ±0.1 %
Mass flow (gas): ±0.35 %
Density (liquid): ±0.0005 g/cm³ -
Measuring range
0 to 2 200 000 kg/h (0 to 80 840 lb/min)
-
Max. process pressure
PN 100, Class 600, 63K
-
Medium temperature range
Standard: –50 to +200 °C (–58 to +392 °F)
High temperature: –50 to +350 °C (–58 to +662 °F) -
Ambient temperature range
Standard: –20 to +60 °C (–4 to +140 °F)
Option: –40 to +60 °C (–40 to +140 °F) -
Sensor housing material
1.4301/1.4307 (304L), corrosion resistant
-
Transmitter housing material
Powder‐coated die‐cast aluminium
1.4301 (304), sheet
CF3M (316L), cast -
Degree of protection
IP67, type 4X enclosure. Remote transmitter: IP67, type 4X enclosure
-
Display/Operation
4‐line backlit display with touch control (operation from outside)
Configuration via local display and operating tools possible -
Outputs
4 modular outputs:
0‐20 mA (active)/4‐20 mA (active/passive)
Pulse/frequency/switch output (passive)
Relay -
Inputs
2 modular inputs:
Status
0‐20 mA (active)/4‐20 mA (active/passive) -
Digital communication
HART, PROFIBUS PA/DP, FOUNDATION Fieldbus, Modbus RS485, EtherNet/IP
-
Power supply
DC 16 to 62 V
AC 85 to 260 V (45 to 65 Hz)
AC 20 to 55 V (45 to 65 Hz) -
Hazardous area approvals
ATEX, IECEx, FM, CSA, NEPSI
-
Other approvals and certificates
3.1 material, calibration performed on accredited calibration facilities (acc. to ISO/IEC 17025), NAMUR, SIL, marine
PED, CRN, AD 2000
3-A, FDA
NACE MR0175/MR0103, PMI; welding test acc. to EN, ASME,NORSOK -
Product safety
CE, C-tick, EAC marking
-
Functional safety
Functional safety according to IEC 61508, applicable in safety-relevant applications in accordance with IEC 61511
-
Metrological approvals and certificates
Calibration performed on accredited calibration facilities (acc. to ISO/IEC 17025), NAMUR
-
Marine approvals and certificates
Marine approval
-
Pressure approvals and certificates
PED, CRN, AD 2000
-
Material certificates
3.1 material
NACE MR0175/MR0103, PMI; welding test acc. to EN, ASME,NORSOK -
Hygienic approvals and certificates
3-A, FDA
-
Measuring principle
Coriolis
-
Product headline
The flowmeter with premium accuracy, robustness and extended transmitter functionality. Highest measurement performance for liquids and gases under varying, demanding process conditions.
-
Sensor features
Highest process safety – immune to fluctuating and harsh environments. Fewer process measuring points – multivariable measurement (flow, density, temperature). Space‐saving installation – no in/outlet run needs. Mass flow: measurement error ±0,05 % (PremiumCal). pressure-rated sensor housing up to 40 bar (580 psi).
-
Transmitter features
Quality – software for filling & dosing, density & concentration, advanced diagnostics. Flexible data transfer options – numerous communication types. Automatic recovery of data for servicing. 4‐ line backlit display with touch control. Device in compact or remote version.
-
Nominal diameter range
DN 8 to 250 (⅜ to 10")
High temperature: DN 25 (1"), DN 50 (2"), DN 80 (3") -
Wetted materials
Measuring tube: 1.4539 (904L); 1.4404 (316/316L); Alloy C22, 2.4602 (UNS N06022)
Connection: 1.4404 (316/316L); Alloy C22, 2.4602 (UNS N06022) -
Measured variables
Mass flow, density, temperature, volume flow, corrected volume flow, reference density, concentration
-
Max. measurement error
Mass flow (liquid): ±0.1 % (standard), 0.05 % (option)
Volume flow (liquid): ±0.1 %
Mass flow (gas): ±0.35 %
Density (liquid): ±0.0005 g/cm³ -
Measuring range
0 to 2 200 000 kg/h (0 to 80 840 lb/min)
-
Max. process pressure
PN 100, Class 600, 63K
-
Medium temperature range
Standard: –50 to +200 °C (–58 to +392 °F)
High temperature: –50 to +350 °C (–58 to +662 °F) -
Ambient temperature range
Standard: –20 to +60 °C (–4 to +140 °F)
Option: –40 to +60 °C (–40 to +140 °F) -
Sensor housing material
1.4301/1.4307 (304L), corrosion resistant
-
Transmitter housing material
Powder‐coated die‐cast aluminium
1.4301 (304), sheet
CF3M (316L), cast -
Degree of protection
IP67, type 4X enclosure. Remote transmitter: IP67, type 4X enclosure
-
Display/Operation
4‐line backlit display with touch control (operation from outside)
Configuration via local display and operating tools possible -
Outputs
4 modular outputs:
0‐20 mA (active)/4‐20 mA (active/passive)
Pulse/frequency/switch output (passive)
Relay -
Inputs
2 modular inputs:
Status
0‐20 mA (active)/4‐20 mA (active/passive) -
Digital communication
HART, PROFIBUS PA/DP, FOUNDATION Fieldbus, Modbus RS485, EtherNet/IP
-
Power supply
DC 16 to 62 V
AC 85 to 260 V (45 to 65 Hz)
AC 20 to 55 V (45 to 65 Hz) -
Hazardous area approvals
ATEX, IECEx, FM, CSA, NEPSI
-
Other approvals and certificates
3.1 material, calibration performed on accredited calibration facilities (acc. to ISO/IEC 17025), NAMUR, SIL, marine
PED, CRN, AD 2000
3-A, FDA
NACE MR0175/MR0103, PMI; welding test acc. to EN, ASME,NORSOK -
Product safety
CE, C-tick, EAC marking
-
Functional safety
Functional safety according to IEC 61508, applicable in safety-relevant applications in accordance with IEC 61511
-
Metrological approvals and certificates
Calibration performed on accredited calibration facilities (acc. to ISO/IEC 17025), NAMUR
-
Marine approvals and certificates
Marine approval
-
Pressure approvals and certificates
PED, CRN, AD 2000
-
Material certificates
3.1 material
NACE MR0175/MR0103, PMI; welding test acc. to EN, ASME,NORSOK -
Hygienic approvals and certificates
3-A, FDA
-
Measuring principle
Coriolis
-
Characteristic / Application
The universal and multivariable flowmeter for liquids and gases
-
Ambient temperature
-20...65°C
(-4...+140°F) -
Process temperature
-50...+350°C
(-58...+662°F) -
Process pressure
PN 16...100
Cl 150...600
JIS 10...63K -
Wetted parts
904L/1.4539
Alloy C-22/2.4602 -
Output
4...20mA
Pulse/Frequency (10KHz, active/passive)
Relays/Status -
Certificates / Approvals
ATEX
FM
CSA
TIIS
-
Measuring principle
Coriolis
-
Product headline
The flowmeter with premium accuracy, robustness and extended transmitter functionality. Highest measurement performance for liquids and gases under varying, demanding process conditions.
-
Sensor features
Highest process safety – immune to fluctuating and harsh environments. Fewer process measuring points – multivariable measurement (flow, density, temperature). Space‐saving installation – no in/outlet run needs. Mass flow: measurement error ±0,05 % (PremiumCal). pressure-rated sensor housing up to 40 bar (580 psi).
-
Transmitter features
Quality – software for filling & dosing, density & concentration, advanced diagnostics. Flexible data transfer options – numerous communication types. Automatic recovery of data for servicing. 4‐ line backlit display with touch control. Device in compact or remote version.
-
Nominal diameter range
DN 8 to 250 (⅜ to 10")
High temperature: DN 25 (1"), DN 50 (2"), DN 80 (3") -
Wetted materials
Measuring tube: 1.4539 (904L); 1.4404 (316/316L); Alloy C22, 2.4602 (UNS N06022)
Connection: 1.4404 (316/316L); Alloy C22, 2.4602 (UNS N06022) -
Measured variables
Mass flow, density, temperature, volume flow, corrected volume flow, reference density, concentration
-
Max. measurement error
Mass flow (liquid): ±0.1 % (standard), 0.05 % (option)
Volume flow (liquid): ±0.1 %
Mass flow (gas): ±0.35 %
Density (liquid): ±0.0005 g/cm³ -
Measuring range
0 to 2 200 000 kg/h (0 to 80 840 lb/min)
-
Max. process pressure
PN 100, Class 600, 63K
-
Medium temperature range
Standard: –50 to +200 °C (–58 to +392 °F)
High temperature: –50 to +350 °C (–58 to +662 °F) -
Ambient temperature range
Standard: –20 to +60 °C (–4 to +140 °F)
Option: –40 to +60 °C (–40 to +140 °F) -
Sensor housing material
1.4301/1.4307 (304L), corrosion resistant
-
Transmitter housing material
Powder‐coated die‐cast aluminium
1.4301 (304), sheet
CF3M (316L), cast -
Degree of protection
IP67, type 4X enclosure. Remote transmitter: IP67, type 4X enclosure
-
Display/Operation
4‐line backlit display with touch control (operation from outside)
Configuration via local display and operating tools possible -
Outputs
4 modular outputs:
0‐20 mA (active)/4‐20 mA (active/passive)
Pulse/frequency/switch output (passive)
Relay -
Inputs
2 modular inputs:
Status
0‐20 mA (active)/4‐20 mA (active/passive) -
Digital communication
HART, PROFIBUS PA/DP, FOUNDATION Fieldbus, Modbus RS485, EtherNet/IP
-
Power supply
DC 16 to 62 V
AC 85 to 260 V (45 to 65 Hz)
AC 20 to 55 V (45 to 65 Hz) -
Hazardous area approvals
ATEX, IECEx, FM, CSA, NEPSI
-
Product safety
CE, C-tick, EAC marking
-
Functional safety
CE, C-tick
-
Metrological approvals and certificates
Calibration performed on accredited calibration facilities (acc. to ISO/IEC 17025), NAMUR
-
Marine approvals and certificates
Marine approval
-
Pressure approvals and certificates
PED, CRN, AD 2000
-
Material certificates
3.1 material
NACE MR0175/MR0103, PMI; welding test acc. to EN, ASME,NORSOK -
Hygienic approvals and certificates
3-A, FDA
-
-
Technical Information (TI)
Promass 80/83 F Karta katalogowa
-
Technical Information (TI)
Polish version - 01/2010New version available in EnglishUniwersalny, wieloparametrowy przepływomierz masowy Coriolisa
dla cieczy i gazów. Jednoczesny pomiar strumienia masy,
objętości,gęstości, temperatury i frakcji.Language:
Polish
Version:
25/01/2010
File size:
1.9 MB
File name:
Ti101dpl_0210.pdf
-
-
-
Operating Instruction (BA)
Promass 83 Instrukcja obsługi: opis montażu
-
Operating Instruction (BA)
Polish version - 12/2006New version available in EnglishPrzepływomierz masowy Coriolisa przeznaczony do pomiaru przep
ływu, gestości i temperatury cieczy oraz gazów.EN 01/12/2006Language:
Polish
Version:
01/12/2006
File size:
2.5 MB
File name:
Ba059dpl.pdf
-
-
File size:
File name:
-
File size:
File name:
-
-
Metrology
Product family: Promass 83
-
Metrology
Romanian version - 06/2006New version available in EnglishProduct root: 83F-
Region: Romania
Approval agency: BRMLLanguage:
Romanian
Version:
22/06/2006
File size:
176.6 KB
File name:
RO_BRML_297_02.pdf
-
-
-
Metrology
Product family: Promass 80, Promass 83
-
Metrology
Romanian version - 06/2006New version available in EnglishProduct root: 80F-, 80M-, 83F-, 83M-
Region: Romania
Approval agency: BRMLLanguage:
Romanian
Version:
22/06/2006
File size:
182.7 KB
File name:
RO_BRML_296_02.pdf
-
-
-
Electronic Device Description (EDD)
Electronic Data Description (EDD) - Promass 83 - FOUNDATION Fieldbus H1
-
Electronic Device Description (EDD)
Language neutral - 11/2016New version available in EnglishAny, FOUNDATION fieldbus System, ITK 4.01
Language:
Language neutral
Version:
09/11/2016
File size:
87 KB
File name:
EH_FF_FL_Promass83_0x1051_0x02_0x01_FFLIB_ITK4_01.zip
-
-
-
Electronic Device Description (EDD)
Electronic Data Description (EDD) - PROMASS 83 PBUS - PROFIBUS PA
-
Electronic Device Description (EDD)
Language neutral - 02/2019New version available in EnglishSIEMENS, PDM, 6.0 SP5
Language:
Language neutral
Version:
22/02/2019
File size:
100.3 KB
File name:
EH_PA_FL_Promass83_0x152A_0x03_0x01_PDM.zip
-
-
-
Electronic Device Description (EDD)
Electronic Data Description (EDD) - PROMASS 83 PBUS - PROFIBUS DP
-
Electronic Device Description (EDD)
Language neutral - 02/2019New version available in EnglishSIEMENS, PDM, 6.0 SP5
Language:
Language neutral
Version:
22/02/2019
File size:
132.9 KB
File name:
EH_DP_FL_Promass83_0x1529_0x07_0x01_PDM.zip
-
-
-
Electronic Device Description (EDD)
Electronic Data Description (EDD) - PROMASS 83 - HART
-
Electronic Device Description (EDD)
Language neutral - 05/2019New version available in EnglishSIEMENS, PDM, 8.2.1
SIEMENS, PDM, 9.1.0.3
SIEMENS, PDM, 9.1.0.4Language:
Language neutral
Version:
03/05/2019
File size:
375.8 KB
File name:
EH_HA_FL_Promass_0x0051_0x09_0x03_PDM.zip
-
-
-
Electronic Device Description (EDD)
Electronic Data Description (EDD) - PROMASS 83 - HART
-
Electronic Device Description (EDD)
Language neutral - 11/2018New version available in EnglishSIEMENS, PDM, 6.0 SP5
Language:
Language neutral
Version:
13/11/2018
File size:
79.5 KB
File name:
EH_HART_FL_Promass83_0x0051_0x04_0x02_PDM.zip
-
-
-
Electronic Device Description (EDD)
Electronic Data Description (EDD) - Promass 83 - HART
-
Electronic Device Description (EDD)
Language neutral - 08/2020New version available in EnglishEmerson, AMS, 13.5
Emerson, AMS, 13.0
Emerson, AMS, 12.5
Emerson, AMS, 12.0
Emerson, AMS, 13.1Language:
Language neutral
Version:
24/08/2020
File size:
416.7 KB
File name:
EH_HA_FL_Promass_0x1151_0x0A_0x01_AMS12.zip
-
-
-
Electronic Device Description (EDD)
Electronic Data Description (EDD) - PROMASS 83 PBUS - PROFIBUS DP
-
Electronic Device Description (EDD)
Language neutral - 02/2019New version available in EnglishSIEMENS, PDM, 6.0 SP5
Language:
Language neutral
Version:
22/02/2019
File size:
179.2 KB
File name:
EH_DP_FL_Promass83_0x1529_0x05_0x01_PDM.zip
-
-
-
Electronic Device Description (EDD)
Electronic Data Description (EDD) - Promass 83 - FOUNDATION Fieldbus H1
-
Electronic Device Description (EDD)
Language neutral - 11/2016New version available in EnglishAny, FOUNDATION fieldbus System, ITK 5.01
Language:
Language neutral
Version:
09/11/2016
File size:
288.3 KB
File name:
EH_FF_FL_Promass83_0x1051_0x04_0x01_FFLIB_ITK5_01.zip
-
-
-
Device Type Manager (DTM)
Device Type Manager (DTM) - Promass 83 - HART
-
Device Type Manager (DTM)
Language neutral - 05/2023New version available in EnglishEndress+Hauser, DeviceCare, 1.07.06
Endress+Hauser, Field Xpert - SMT70, 1.07.00
Endress+Hauser, FieldCare, 2.17.00Language:
Language neutral
Version:
13/05/2023
File size:
230.8 MB
File name:
EH_Promass_83_V2_01_0x.zip
-
-
-
Device Type Manager (DTM)
Device Type Manager (DTM) - Promass 83 - PROFIBUS DP
-
Device Type Manager (DTM)
Language neutral - 05/2023New version available in EnglishEndress+Hauser, DeviceCare, 1.07.06
Endress+Hauser, Field Xpert - SMT70, 1.07.00
Endress+Hauser, FieldCare, 2.17.00Language:
Language neutral
Version:
16/05/2023
File size:
229.3 MB
File name:
EH_Promass_83_DP_V1_01_xx.zip
-
-
-
Device Type Manager (DTM)
Device Type Manager (DTM) - Promass 83 - FOUNDATION Fieldbus H1
-
Device Type Manager (DTM)
Language neutral - 05/2023New version available in EnglishEndress+Hauser, DeviceCare, 1.07.06
Endress+Hauser, Field Xpert - SMT70, 1.07.00
Endress+Hauser, FieldCare, 2.17.00Language:
Language neutral
Version:
14/05/2023
File size:
108 MB
File name:
EH_Promass_83_FF_V2_00_xx_DevRev3.zip
-
-
-
Device Type Manager (DTM)
Device Type Manager (DTM) - Promass 83 - HART
-
Device Type Manager (DTM)
Language neutral - 05/2023New version available in EnglishEndress+Hauser, DeviceCare, 1.07.06
Endress+Hauser, Field Xpert - SMT70, 1.07.00
Endress+Hauser, FieldCare, 2.17.00Language:
Language neutral
Version:
13/05/2023
File size:
228.3 MB
File name:
EH_Promass_83_V1_05_0x.zip
-
-
-
Device Type Manager (DTM)
Device Type Manager (DTM) - Promass 83 - PROFIBUS PA
-
Device Type Manager (DTM)
Language neutral - 05/2023New version available in EnglishEndress+Hauser, DeviceCare, 1.07.06
Endress+Hauser, Field Xpert - SMT70, 1.07.00
Endress+Hauser, FieldCare, 2.17.00Language:
Language neutral
Version:
16/05/2023
File size:
229.3 MB
File name:
EH_Promass_83_PA_V1_01_xx.zip
-
-
-
Device Type Manager (DTM)
Device Type Manager (DTM) - Promass 83 - HART
-
Device Type Manager (DTM)
Language neutral - 05/2023New version available in EnglishEndress+Hauser, DeviceCare, 1.07.06
Endress+Hauser, Field Xpert - SMT70, 1.07.00
Endress+Hauser, FieldCare, 2.17.00Language:
Language neutral
Version:
13/05/2023
File size:
230.6 MB
File name: