Try searching by key words, order- or product code or serial number e.g. “CM442” or “Technical information”
Enter at least 2 characters to start the search.
Picture of ultrasonic flowmeter Proline Prosonic Flow 93C for water and wastewater applications

Proline Prosonic Flow 93C
ultrasonic flowmeter

Accurate flowmeter for large pipes up to DN 1200 and with a wide range of outputs

93C
please wait
Loading price
Prices temporarily unavailable
Price on request
from CHF ??.-
  • Measuring principle

    Ultrasonic flow

  • Product headline

    Accurate flowmeter for large pipes up to DN 1200 and with a wide range of outputs.
    Inline flow measurement of process water, salt water, demineralized water, drinking and wastewater.

  • Sensor features

    No production losses – removal or replacement of sensor elements without process shutdown. No additional pressure loss – full-bore design. Process transparency – diagnostic capability.
    Internationally recognized drinking water approvals. Nominal diameter: DN 300 to 1200 (12 to 48"). Medium temperature: –10 to 80 °C (14 to 176 °F).

  • Transmitter features

    Highest performance – extended functionality and diagnostics. Flexible data transfer options – numerous communication types. Automatic recovery of data for servicing.
    Aluminium transmitter housing. 4‐line backlit display with touch control. HART, PROFIBUS PA/DP, FOUNDATION Fieldbus.

  • Nominal diameter range

    DN 300 to 1200(12" to 48")

  • Wetted materials

    Sensor housing: 1.4404/DN 17440 (316L/AISI)
    Weld-in parts: 1.4404/DN 17440 (316L/AISI)
    Measuring pipe: ST 37.2 (carbon steel)

  • Measured variables

    Volume flow channel 1 or 2, sound velocity, flow velocity, average volume flow, average sound velocity, average flow velocity, totalizer

  • Max. measurement error

    +/-0.5 %

  • Measuring range

    0 to 40000 m3/h 0 to 180000GPM

  • Max. process pressure

    PN 16, Cl. 150

  • Medium temperature range

    -20 to +60°C (-4 to 140°F)

  • Ambient temperature range

    Transmitter:
    –20 to +60 °C (–4 to +140 °F)
    Sensor:
    –20 to +80 °C (–4 to +176 °F)

  • Transmitter housing material

    Wall-mounted housing: powder-coated die-cast aluminum

  • Degree of protection

    Transmitter
    IP 67 (NEMA 4X)
    Sensor
    IP 68 (NEMA 6P)

  • Display/Operation

    4 lines backlit display with three optical keys

  • Outputs

    1x 4-20 mA HART
    1x Pulse/frequency/switch output (passive)

  • Inputs

    N/A

  • Digital communication

    HART, PROFIBUS PA, PROFIBUS DP, FOUNDATION Fieldbus

  • Power supply

    AC 85 to 260 V
    AC 20 to 55 V
    DC 16 to 62V

  • Hazardous area approvals

    FM
    CSA

  • Product safety

    CE, C-Tick

Configure to download the CAD drawings of this product