Seminar
Proline Promag W 800
Electromagnetic flowmeter
Battery-powered flowmeter with EN ISO 12944 corrosion protection & intelligent energy efficient mode
Promag W is the specialized sensor for all applications in the water industry. Combined with the battery-powered transmitter Proline 800 for the measurement of water and wastewater, PromagW 800 will be the preferred solution for all applications in this industry, which are in locations without power grid. It offers worldwide transmission of measured data and events via e‐mail and SMS.
- F
- L
- E
- X
-
Standard products
- Reliable, robust and low-maintenance
Technical excellence
Simplicity
-
Specialized products
- Designed for demanding applications
Technical excellence
Simplicity
Variable
FLEX selections | Technical excellence | Simplicity |
---|---|---|
Fundamental selection Meet your basic measurement needs |
Technical excellence
|
Simplicity
|
Lean selection Handle your core processes easily |
Technical excellence
|
Simplicity
|
Extended selection Optimize your processes with innovative technologies |
Technical excellence
|
Simplicity
|
Xpert selection Master your most challenging applications |
Technical excellence
|
Simplicity
Variable |
This product is not available in this market.
-
Specs at a glance
-
Max. measurement error
Volume flow: ±0.5 % o.r. ± 2 mm/s (±0.5 % o.r. ± 0.08 in/s)
-
Measuring range
15 dm³/min to 2500 m³/h (4 to 11 000 gal/min)
-
Medium temperature range
Liner material hard rubber: 0 to +80 °C (+32 to +176 °F)
Liner material polyurethane: –20 to +50 °C (–4 to +122 °F) -
Max. process pressure
PN 40, Class 300, 20K
-
Wetted materials
Liner: polyurethane; hard rubber
Electrodes: 1.4435 (316L); Alloy C22, 2.4602 (UNS N06022)
-
Quick selection
Individual configuration
-
Benefits
For direct underground installation or permanent underwater use – certified sensor
Secure, reliable long-term operation – robust and completely welded sensor
Energy-saving flow measurement – no pressure loss due to cross-section constriction
Maintenance-...
-
Field of application
The bidirectional measuring principle is virtually independent of pressure, density, temperature and viscosity
Certified sensor for the most demanding water and wastewater applications
Device properties
International drinking water approvals
Degree of...
Documents / Manuals / Software
-
Proline Promag W 800
Technical Information
Electromagnetic flowmeter
Technical Information (TI) -
Proline Promag W 800
Operating Instructions
Electromagnetic flowmeter
Operating Instruction (BA) -
Proline Promag W 800
Brief Operating Instructions
Electromagnetic flowmeter
Short Instruction (KA)11/14English -
Proline Promag
Brief Operating Instructions
Proline Promag
Part 1 of 2
Electromagnetic sensorShort Instruction (KA)04/17English -
Flowmeter
Proline Promag W
Electromagnetic sensor
Short Instruction (KA)01/20English -
Proline Promag 800
Installation Instruction
Replacing battery
Installation Instructions (EA) -
Interface parts
Installation Instructions
Promag 10, 23, 50, 51, 53, 55, 400, 800
Installation Instructions (EA) -
Potting compound IP68
Promag 400 Remote Version, Promag 800 Remote Version, Promag 500, t-mass
500-digitalInstallation Instructions (EA) -
Safety Instructions for Spare Parts
Installation Instructions
Flowmeter
Installation Instructions (EA) -
Activating the battery on connection B2
Installation Instructions
Promag 800 L, W
Installation Instructions (EA) -
Repair kit cover remote version
Installation Instructions
Promag 10, 50, 51, 53, 55, 400, 800, Promass 80, 83, 84, CNGmass DCI,
Cubemass DCI, Prosonic Flow 92 F, t-mass 65Installation Instructions (EA) -
Installing ground disks
Promag 10, 23, 50, 51, 53, 55, 100, 200, 300, 500, 800, 400 Index C
Installation Instructions (EA) -
Replacing Sensor parts remote version
Installation Instructions
Promag 10, 50, 51, 53, 55, 400, 800, Promass 80, 83, 84, Cubemass 8CN,
CNGmass 8DFInstallation Instructions (EA) -
Replacing cover and O-ring
Installation Instructions
romag 10, 23, 50, 51, 53, 55, 400, 800, Promass 40, 80, 83, 84, 8ME,
CNGmass 8FF, LPGmass 8FE, Cubemass 8CM, Prosonic Flow 90, 91,9
2, 93, t-mass 65, Prowirl 72, 73Installation Instructions (EA) -
Replacing the transmitter
Installation Instructions
Promag 800 W, L
Installation Instructions (EA) -
Replacing spare parts
Installation Instructions
Promag 800 Compact Version, Remote Version
Installation Instructions (EA) -
Replacing Small Parts
Promag 400 , Promag 800 Index B, Cubemass, Promag 500, Promag, Promass,
Prosonic Flow, t-mass 500-digitalInstallation Instructions (EA) -
Replacing Protective Cover
Installation Instructions
Promag 400 Compact Version, Promag 800 Compact Version
Installation Instructions (EA) -
Promag 800
OPC Server
Special Documentation
Electromagnetic flowmeter
Special Documentation (SD) -
Change of Directives
Special Documentation
Change of Directives
Special Documentation (SD) -
Proline Promag W 800
Additional note
Special Documentation
Zusatznotiz zur EG-Konformitätserklärung zur Messgeräterichtlinie
Additional note to the EC declaration of conformity for the measuring
instruments directive
Note complémentaire à la déclaration de conformité CE relative à la
directive sur les instruments de mesureSpecial Documentation (SD) -
Proline Promag W 400/800
Supplementary documentation for the Operating Instructions
Special Documentation
Electromagnetic flow measuring system
Special Documentation (SD) -
Proline Promag W 800
Das batteriebetriebene Durchflussmessgerät für die Wasserindustrie
Innovations (IN)05/14German -
Proline Promag W 800
The battery-powered flowmeter for the water industry
Innovations (IN)05/14English -
Proline Promag W 800
Bateriově napájený průtokoměr pro vodní hospodářství
Innovations (IN)05/14Czech -
Proline Promag 800
Il misuratore di portata a batteria per "le acque"
Innovations (IN)01/13Italian -
Promag W800
Batteriebetriebenes magnetisch-induktives Durchflussmessgerät,
mikroprozessorgesteuert und überwacht in Kompakt-Bauweise.Tender Text08/12German -
Promag W800
Battery powered electromagnetic flow meter, microprocessor based and
self checking,
compact versionTender Text07/15English -
Proline Promag 800 OPC Server
This OPC Server manages the battery-operated Promag L/W 800
electromagnetic flowmeter. It enables data access to e-mails sent by the
Endress+Hauser Promag L/W 800 electromagnetic flowmeter. The data is
made available to OPC clients in a CSV file. The data is accessed via
email.Configuration Software1.00.11.00Language neutral -
Configuration Software Config5800
Communication via wireless GSM/GPRS
Configuration Software1.0.1.0Language neutral -
Promag W
Product Code: 5W8B-
Declaration Number: EC_00275_01.16EU DeclarationGerman , English , fr -
Promag W
Product Code: 5W8B-
Declaration Number: EC_00109_02.15EU DeclarationGerman , English , fr -
Promag 10, Promag 50, Promag 51, Promag 53, Promag D, Promag E, Promag H, Promag L, Promag P, Promag W
Product Code: 53L-, 53P-, 53W-, 5D4B-, 5D4C-, 5E1B-, 5E2B-, 5H1B-, 5H2B-, 5L4B-, 5L4C-, 5P1B-, 5P2B-, 5W4B-, 5W4C-, 5W8B-, 53H-, 53E-, 51W-, 51P-, 50W-, 50P-, 50L-, 50H-, 50E-, 50D-, 10W-, 10P-, 10L-, 10H-, 10E-, 10D-
Region/Country: Russia (TR CU)
Approval Agency: EAC
Approval Number: TC BY_112 11.01. TP020 003 126MiscellaneousRussian -
Promag W, Promag P, Promag L, Promag H, Promag E, Promag D, Promag 55, Promag 53, Promag 51, Promag 50, Promag 10, Dosimag
Product Code: 55S-, 5D4B-, 5D4C-, 5E1B-, 5H-, 5H1B-, 5H3B-, 5H5B-, 5L4B-, 5L4C-, 5P1B-, 5P3B-, 5P5B-, 5W3B-, 5W4D-, 5W5B-, 5W8B-, 5W8C-, DDA-, 55H-, 53W-, 53P-, 53L-, 53H-, 53E-, 51W-, 51P-, 50W-, 50P-, 50L-, 50H-, 50E-, 50D-, 10W-, 10P-, 10L-, 10H-, 10E-, 10D-
Region/Country: Russia (TR CU)
Approval Agency: EAC
Approval Number: EAEC N RU D-CH.AD07.B.02228/20MiscellaneousRussian -
Promass K, Promass O, Promass P, Promass Q, Promass S, Promass X, Prosonic Flow 91, Prosonic Flow 92, Prosonic Flow 93, Prosonic Flow G, Prowirl D, Prowirl F, Prowirl O, Prowirl R, t-mass, t-mass A, t-mass B, T-MASS F, T-MASS I, Promass I, CNGmass, Dosimag, Dosimass, LNGmass, LPGmass, Promag 10, Promag D, Promag E, Promag H, Promag L, Promag P, Promag W, Promass 40, Promass 80, Promass 83, Promass 84, Promass E, Promass F, Promass H
Product Code: 8I3B-, 8I1B-, 8H5B-, 8H3B-, 8F5B-, 8F3B-, 8F2B-, 8F1B-, 8E5B-, 8E3B-, 8E2C-, 8E2B-, 8E1C-, 8E1B-, 8E-, 84X-, 84F-, 83X-, 83F-, 80F-, 7R2C-, 8I5B-, 8K1B-, 8O3B-, 8O5B-, 8P1B-, 8P3B-, 8P5B-, 8Q3B-, 8Q5B-, 8S1B-, 8S1C-, 8S3B-, 8S5B-, 8X3B-, 8X5B-, 91W-, 92F-, 93C-, 93W-, 9G3B-, 9G5B-, DDA-, 7R2B-, 10D-, 10E-, 10H-, 10L-, 10P-, 10W-, 40E-, 5D4B-, 5D4C-, 5E1B-, 5E2B-, 5H-, 5H1B-, 5H2B-, 5H3B-, 5H5B-, 5L4B-, 5L4C-, 5P1B-, 5P2B-, 5P3B-, 5P5B-, 7O2C-, 7O2B-, 7F2C-, 7F2B-, 7D2C-, 7D2B-, 6I5B-, 6I3B-, 6F5B-, 6F3B-, 6BAB-, 6AAB-, 65I-, 65F-, 5W8C-, 5W8B-, 5W5B-, 5W4D-, 5W4C-, 5W4B-, 5W3B-
Region/Country: Russia (TR CU)
Approval Agency: EAC
Approval Number: EAEC N RU D-CH.AD07.B.03271/20MiscellaneousRussian -
Promag W, Promag P, Promag L, Promag H, Promag E, Promag D, Promag 55, Promag 53, Promag 51, Promag 50, Promag 10, Dosimag, Promass X, Promass S, Promass Q, Promass P, Promass O, Promass I, Promass H, Promass F, Promass E, Promass A, Promass 84, Promass 83, Promass 80, Dosimass OEM
Product Code: 5D4C-, 5P5B-, 5W5B-, 5P3B-, 5H5B-, 5W3B-, 5W4C-, 5L4C-, 53P-, 53W-, 5P1B-, 5H1B-, 5H3B-, 50W-, 50P-, 50H-, 53H-, 5E1B-, 55S-, 5P2B-, 53L-, 55H-, 5H2B-, 50L-, 53E-, 50D-, 50E-, 51W-, 5H-, 5L4B-, 5W4D-, 5W4B-, 5W8B-, 5W8C-, DDA-, 5D4B-, 10D-, 10E-, 10H-, 10P-, 10W-, 10L-, 51P-, 8E5B-, 8F1B-, 8F2B-, 8F3B-, 8H1B-, 8H3B-, 8H5B-, 8I1B-, 8I3B-, 8I5B-, 8O1B-, 8O3B-, 8P1B-, 8P3B-, 8P5B-, 8Q3B-, 8Q5B-, 8S1B-, 8S3B-, 8S5B-, 8X3B-, 8X5B-, 80A-, 80E-, 80F-, 80I-, 80P-, 80S-, 83A-, 83E-, 83F-, 83H-, 83I-, 83P-, 83S-, 83X-, 84F-, 84X-, 8A1B-, 8A3B-, 8A5B-, 8BE-, 8E1B-, 8E2B-, 8E3B-
Region/Country: Russia (TR CU)
Approval Agency: EAC
Approval Number: EAEC N RU D-CH.AD07.B.02246/20MiscellaneousRussian -
Promag 10, Promag 50, Promag 51, Promag 55, Promag D, Promag E, Promag H, Promag L, Promag P, Promag W
Product Code: 55H-, 55S-, 5D4C-, 5E1B-, 5H2B-, 5H3B-, 5L4B-, 5P1B-, 5P2B-, 5P3B-, 5P5B-, 5W4C-, 5W8B-, 51W-, 51P-, 50W-, 50P-, 50L-, 50H-, 50E-, 50D-, 10W-, 10P-, 10L-, 10H-, 10E-, 10D-
Region/Country: Russia (TR CU)
Approval Agency: EAC
Approval Number: TC RU D-CH.MU62.B.02333MiscellaneousRussian -
Promag 10, Promag 50, Promag 51, Promag 53, Promag 55, Promag L, Promag P, Promag W
Product Code: 5W8C-, 5W8B-, 5W5B-, 5W4C-, 5W4B-, 5W3B-, 5L8B-, 5L4C-, 5L4B-, 55S-, 53W-, 53L-, 51W-, 50W-, 50L-, 10W-, 10L-
Region/Country: France
Approval Agency: ACSHygienic EquipmentEnglish -
Promag 10, Promag 50, Promag 51, Promag 53, Promag L, Promag W
Product Code: 10W-, 50L-, 50W-, 51W-, 53W-, 5L4C-, 5W4B-, 5W4C-, 5W5B-, 5W8B-, O5W1B-
Region/Country: Germany
Approval Agency: HyHygienic EquipmentGerman -
Promag 10, Promag 50, Promag 51, Promag 53, Promag L, Promag W
Product Code: O5W1B-, 5W8B-, 5W5B-, 5W4C-, 5W4B-, 5L4C-, 53W-, 53L-, 51W-, 50W-, 50L-, 10W-, 10L-
Region/Country: Germany
Approval Agency: HyHygienic EquipmentGerman -
Promag 10, Promag 50, Promag 51, Promag 53, Promag L, Promag W
Product Code: O5W1B-, 5W8B-, 5W5B-, 5W4C-, 5W4B-, 5L4C-, 53W-, 51W-, 50W-, 10W-
Region/Country: France
Approval Agency: ACSHygienic Equipmentfr -
Promag 10, Promag W, Promag 53, Promag 50, Promag 51, Promag L
Product Code: O5W1B-, 53W-, 50W-, 5W4C-, 53L-, 50L-, 5W5B-, 5W4B-, 51W-, 10W-, 10L-, 5W8B-, 5L4B-, 5L4C-, 5L8B-
Region/Country: Great Britain
Approval Agency: WRASHygienic EquipmentEnglish -
Promag W, Promag 10, Promag 50, Promag 53, Promag L
Product Code: 5W5B-, 5W4C-, 5L4C-, 53W-, 50W-, 53L-, 50L-, 10L-, 10W-, 5W4B-, 5W8B-, O5W1B-
Region/Country: Germany
Approval Agency: HyHygienic EquipmentGerman -
Promag 10, Promag W, Promag 53, Promag 50, Promag 51, Promag L
Product Code: O5W1B-, 53W-, 50W-, 5W4C-, 53L-, 50L-, 5W5B-, 5W4B-, 51W-, 10W-, 10L-, 5W8B-, 5L4C-, 5L8B-
Region/Country: Great Britain
Approval Agency: WRASHygienic EquipmentEnglish -
Promag 10, Promag 50, Promag 51, Promag 53, Promag L, Promag W
Product Code: O5W1B-, 5W8B-, 5W5B-, 5W4C-, 5W4B-, 5L4C-, 53W-, 51W-, 50W-, 10W-
Region/Country: Great Britain
Approval Agency: WRASHygienic EquipmentEnglish -
Promag 10, Promag 50, Promag 51, Promag 53, Promag 55, Promag L, Promag W
Product Code: 5W8C-, 5W8B-, 5W5B-, 5W4C-, 5W4B-, 5W3B-, 5L8B-, 5L4C-, 5L4B-, 55S-, 53W-, 53L-, 51W-, 50W-, 50L-, 10W-, 10L-
Region/Country: France
Approval Agency: ACSHygienic Equipmentfr -
Promag 10, Promag 50, Promag 51, Promag 53, Promag L, Promag W
Product Code: O5W1B-, 5W8B-, 5W5B-, 5W4C-, 5W4B-, 5L4C-, 53W-, 51W-, 50W-, 10W-
Region/Country: USA
Approval Agency: NSFHygienic EquipmentEnglish -
Promag 10, Promag W, Promag 53, Promag 50, Promag 51, Promag L
Product Code: O5W1B-, 53W-, 50W-, 5W4C-, 53L-, 50L-, 5W5B-, 5W4B-, 51W-, 10W-, 10L-, 5W8B-, 5L4B-, 5L4C-, 5L8B-
Region/Country: Great Britain
Approval Agency: WRASHygienic EquipmentEnglish -
Promag 10, Promag 50, Promag 51, Promag 53, Promag L, Promag W
Product Code: O5W1B-, 5W8B-, 5W5B-, 5W4C-, 5W4B-, 5L4C-, 53W-, 51W-, 50W-, 50L-, 10W-
Region/Country: Germany
Approval Agency: HyHygienic EquipmentGerman -
Promag 10, Promag 50, Promag 51, Promag 53, Promag D, Promag L, Promag P, Promag W
Product Code: 5L4B-, 5L4C-, 5L8B-, 5P1B-, 5P2B-, 5P3B-, 5P5B-, 5W4B-, 5W4C-, 5W5B-, 5W8B-, O5P1B-, O5P2B-, O5W1B-, 10D-, 10L-, 10P-, 10W-, 50D-, 50L-, 50P-, 50W-, 51P-, 51W-, 53P-, 53W-, 5D4B-, 5D4C-
Region/Country: USA
Approval Agency: NSFHygienic EquipmentEnglish -
Promag 10, Promag 50, Promag 51, Promag 53, Promag W
Product Code: O5W1B-, 5W8B-, 5W5B-, 5W4C-, 5W4B-, 53W-, 51W-, 50W-, 10W-
Region/Country: USA
Approval Agency: NSFHygienic EquipmentEnglish -
Promag 10, Promag 50, Promag 51, Promag 53, Promag 55, Promag L, Promag W
Product Code: 5W8C-, 5W8B-, 5W5B-, 5W4C-, 5W4B-, 5W3B-, 5L8B-, 5L4C-, 5L4B-, 55S-, 53W-, 53L-, 51W-, 50W-, 50L-, 10W-, 10L-
Region/Country: France
Approval Agency: ACSHygienic EquipmentEnglish -
Promag D, Promag P, Promag W, Promag H, Promag L, Promag E
Product Code: 5W8B-, 5W4C-, 5L4C-, 5P1B-, 5H1B-, 5H3B-, 5E1B-, 5P2B-, 5D4C-, 5H2B-, 5W4B-, 5L4B-, 5E2B-, 5D4B-
Region/Country: Russia
Approval Agency: Rosstandart
Approval Number: CH.C.29.004.А NO. 59660/1MetrologyRussian -
Promag W, Promag P, Promag L, Promag H, Promag E, Promag D, Promag 55, Promag 53, Promag 51, Promag 50, Promag 10
Product Code: 55S-, 5D4B-, 5D4C-, 5E1B-, 5H1B-, 5H2B-, 5H3B-, 5H5B-, 5L4B-, 5L4C-, 5P1B-, 5P2B-, 5P3B-, 5P5B-, 5W4B-, 5W4C-, 5W5B-, 5W8B-, 55H-, 53W-, 53P-, 53L-, 53H-, 53E-, 51W-, 51P-, 50W-, 50P-, 50L-, 50H-, 50E-, 10W-, 10P-, 10L-, 10H-, 10E-, 10D-
Region/Country: Uzbekistan
Approval Agency: UZS
Approval Number: 02.6720MetrologyRussian
Accessories / Spare parts
-
-
Nr 83 Order code 71182805
Kit antenna, 3m cable, Promag 800
Consists of: Antenna with 3m cable, mounting bracket.
-
-
-
Nr 45 Order code 71187755
Kit connection terminals, Promag 800
Consists of: Connection terminal 3-Pol. Connection terminal 4-Pol. Connection terminal 4-Pol. Connection terminal 6-Pol.
-
-
-
Nr 44 Order code 50098018
-
-
-
Nr 51 Order code 71182798
Kit cover with display, Promag 800
Consists of: Cover plastic complete incl. display. O-Ring 195 x 3.53 EPDM. 2 x Hinge pin L= 58mm plastic.
-
-
-
Nr 24 Order code 71188176
Kit cover plastic, remote, Promag L/W
Usage: Promag 400/800, Promag 500, sensor connection housing. Consists of: cover plastic coated, O-Ring 91,67 x 3,53 FKM.
-
Nr 24 Order code 50094038
-
Nr 24 Order code 71247838
Repair kit cover, remote version
Usage: 10/5X/8X/8DF/8CN/92F/65/400/800 acc. service info SI01351D-1/06 Consists of: Cover Rep.kit for G14, O-Ring 110.00 x 4.50 HNBR, Grease
-
-
-
Nr 11 Order code 71182804
Kit PCB/battery carrier, Promag 800
-
-
-
Nr 25 Order code 71182806
Kit 10 cover gasket, Promag 400(B)/800
Usage: Promag 400(B)/800 with polycarbonate housing. (B) = generation index B. Consists of: 10x O-Ring 195 x 3,53 EPDM.
-
-
-
Nr 72 Order code 71188179
Kit cover gasket, plastic, Promag L/W
Usage: Promag 400/800, Promag 500, sensor connection housing. Consists of: 10x O-Ring 91,67 x 3,53 FKM.
-
-
-
Nr 71 Order code 71182807
Kit housing gasket, D/L/W, compact
Usage: Promag 400/800. Consists of: Gasket EPDM for housing/sensor D. Gasket EPDM for housing/sensor L/W.
-
-
-
Nr 73 Order code 50098023
Kit housing gasket FS Stnd/HT
Usage: 10/50/51/53/55/400/800 Sensor: D/E/L/P/S/W
-
-
-
Nr 12 Order code 71188175
Kit housing parts, D/L/W, compact
Usage: Promag 400/800 with sensor D/L/W. Consists of: Screw M6x28 A2, washer spring M6 A4, for housing/sensor D. Screw M5x35 A2 for housing/sensor L/W.
-
-
-
Nr 13 Order code 50098019
Kit parts housing FS Stnd/HT
Usage: 10/50/51/53/55/400/800 Sensor: D/E/H/L/P/S/W
-
-
-
Nr 15 Order code 50103658
Kit 10 cable glands M20x1,5 grey
-
Nr 15 Order code 50098041
Kit 10 ext. M20x1.5/G 1/2" (plug PVC)
-
Nr 15 Order code 50098042
Kit 10 ext. M20x1.5/NPT 1/2" (plug PVC)
-
Nr 15 Order code 50103658
Kit 10 cable glands M20x1,5 grey
-
Nr 15 Order code 50103658
Kit 10 cable glands M20x1,5 grey
-
Nr 15 Order code 50098041
Kit 10 ext. M20x1.5/G 1/2" (plug PVC)
-
Nr 15 Order code 50098042
Kit 10 ext. M20x1.5/NPT 1/2" (plug PVC)
-
-
-
Nr 17 Order code 50096840
Kit 10 cable glands M20x1,5
-
Nr 17 Order code 71029350
Kit 2 cable gland M20x1,5 reinf.Sensor
-
Nr 17 Order code 50098036
Kit 10 cable glands M20x1.5 Ex
-
Nr 17 Order code 50098041
Kit 10 ext. M20x1.5/G 1/2" (plug PVC)
-
Nr 17 Order code 50098042
Kit 10 ext. M20x1.5/NPT 1/2" (plug PVC)
-
-
-
Nr 82 Order code 71182808
Kit weather prot. cover, Promag 400/800
Consists of: Weather protective cover, installation material.
-
-
-
Nr 53 Order code 71189203
Kit display protection cover,Promag 800
-
-
-
Nr 49 Order code DK5004-
Battery Set Promag W,L 800
Configuration must be compatible with power supply of the ordered Promag 800. Select configuration by document "Technical Information".
-
-
-
Order code 5X8BXX-
Transmitter Promag 800, 5X8BXX
Battery powered Transmitter incl. Display, data logger and Micro SD Card intergrated
-
Order code DK5CA-
Promag, cable remote version
10/50/51/53/55/400/800 1 kit includes 1 coil cable and 1 signal cable
-
Order code DK5WM-
-
Order code DK5GD-
Promag, grounding disc/protection disc
Includes 1 grounding disc/protection disc
-
Order code DK5GC-
-
Order code XPRFID-
-
-
Predecessor
-